# Changelog

> Full change history for Sky Fire Job.

<u-changelog-versions>
<u-changelog-version date="2026-11-20" title="Version 1.24.0" badge="Current">
<template v-slot:body="">

**Highlights**

- Fixed an issue where fire-service invoice previews could show a different currency from the configured Sky invoice currency.

**Other Changes**

- Corrected fire-service, dispatch and equipment terminology in the bundled translations.

**Changed Files**

- `sky_firejob/config/locales/*`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/source/*` — delete and reinsert

<update-guide from="1.23.0" resource="sky_firejob" to="1.24.0">
<template v-slot:simplified="">

### 1. Back up and stop

Download Fire 1.24.0, Sky Base 1.55.0 and Jobs Base 1.58.0. These Fire steps start from 1.23.0; complete intervening guides first for older installations. Back up the installed resource, configuration, custom translations and the server database, including saved fire-job settings and incident data. Stop the server.

### 2. Install the matching files

Open the installed sky_firejob folder containing fxmanifest.lua. Delete the old source/ directory and copy in the complete new source/ directory from this download. Replace fxmanifest.lua from the same package. Replace the entire config/locales/ directory; copy only your own edited text into the corresponding new keys and retain every supplied key.

### 3. Keep settings and configure

Keep config/config.lua, all existing billing and dispatch settings, your vehicle and hose layouts, and saved /jobconfig Fire overrides. This release adds no configuration key. Copy only your customized translation text into matching new entries and retain every supplied key.

### 4. Database, items and assets

Preserve existing incidents, equipment, jobs, inventory registrations and saved settings. No SQL import, new item, configuration import or stream-asset replacement is required by this release.

### 5. Start and check

Apply the Base 1.55.0 and Jobs Base 1.58.0 guides first. Keep the configured providers before Base, then start Jobs Base and Fire. Restart the server and reconnect. Open the Fire billing printer and check the amount and currency against the configured Sky invoice currency. Confirm existing jobs and equipment remain available.

</template>

<template v-slot:prepare="">

Download Fire 1.24.0, Sky Base 1.55.0 and Jobs Base 1.58.0. These Fire steps start from 1.23.0; complete intervening guides first for older installations. Back up the installed resource, configuration, custom translations and the server database, including saved fire-job settings and incident data. Stop the server.

</template>

<template v-slot:files="">

Open the installed sky_firejob folder containing fxmanifest.lua. Delete the old source/ directory and copy in the complete new source/ directory from this download. Replace fxmanifest.lua from the same package. Replace the entire config/locales/ directory; copy only your own edited text into the corresponding new keys and retain every supplied key.

</template>

<template v-slot:config="">

Keep config/config.lua, all existing billing and dispatch settings, your vehicle and hose layouts, and saved /jobconfig Fire overrides. This release adds no configuration key. Copy only your customized translation text into matching new entries and retain every supplied key.

</template>

<template v-slot:data="">

Preserve existing incidents, equipment, jobs, inventory registrations and saved settings. No SQL import, new item, configuration import or stream-asset replacement is required by this release.

</template>

<template v-slot:verify="">

Apply the Base 1.55.0 and Jobs Base 1.58.0 guides first. Keep the configured providers before Base, then start Jobs Base and Fire. Restart the server and reconnect. Open the Fire billing printer and check the amount and currency against the configured Sky invoice currency. Confirm existing jobs and equipment remain available.

</template>
</update-guide>
</template>
</u-changelog-version>
</u-changelog-versions>

<u-changelog-version date="2026-11-17" title="Version 1.23.0">
<template v-slot:body="">

**Highlights**

- Improved the spacing of external billing notices in the tablet.
- Improved the configurator asset picker with a compact layout and clearer keyboard focus.

**Changed Files**

- `sky_firejob/fxmanifest.lua`
- `sky_firejob/source/*` — delete and reinsert
- `sky_firejob/config/locales/*`

<update-guide from="1.22.0" resource="sky_firejob" to="1.23.0">
<template v-slot:simplified="">

### 1. Back up and stop

Download Sky Fire Job 1.23.0. Start from 1.22.0 or complete the intervening update guides first. Back up the resource, custom configuration, translations and database, then stop the server.

### 2. Install the matching files

Open the installed `sky_firejob` folder containing `fxmanifest.lua`. Replace the complete `source/` and `config/locales/` directories and `fxmanifest.lua`.

### 3. Keep settings and configure

Keep the existing `config/config.lua`, `config/functions.lua`, custom images and saved `/jobconfig` settings. Reapply custom translations after copying the new locales.

### 4. Database, items and assets

Keep the existing Fire Job records. This update requires no SQL import, item changes or stream asset changes.

### 5. Start and check

Use the current supported Sky Base and Jobs Base and start both before Fire Job. Open the tablet billing panel and check the external billing notice if you use a provider. Open the configurator asset picker and check that you can select an asset.

</template>

<template v-slot:prepare="">

Download Sky Fire Job 1.23.0. Start from 1.22.0 or complete the intervening update guides first. Back up the resource, custom configuration, translations and database, then stop the server.

</template>

<template v-slot:files="">

Open the installed `sky_firejob` folder containing `fxmanifest.lua`. Replace the complete `source/` and `config/locales/` directories and `fxmanifest.lua`.

</template>

<template v-slot:config="">

Keep the existing `config/config.lua`, `config/functions.lua`, custom images and saved `/jobconfig` settings. Reapply custom translations after copying the new locales.

</template>

<template v-slot:data="">

Keep the existing Fire Job records. This update requires no SQL import, item changes or stream asset changes.

</template>

<template v-slot:verify="">

Use the current supported Sky Base and Jobs Base and start both before Fire Job. Open the tablet billing panel and check the external billing notice if you use a provider. Open the configurator asset picker and check that you can select an asset.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-11-09" title="Version 1.22.0">
<template v-slot:body="">

**Highlights**

- Added the option to take, visibly carry, exchange and return rescue tools at configured fire vehicles instead of requiring inventory items.

**Notable Changes**

- Fixed an issue where other firefighters' hoses disappeared after their vehicles left and re-entered streaming range.
- Fixed an issue where lowered EU nozzles kept an unnatural hose bend around the firefighter's arm.
- Fixed an issue where holding a pump vehicle in place also blocked ladder controls that share the driving inputs.
- Added radial-menu access to operate nearby hose-divider valves.
- Fixed an issue where custom extinguisher mounts were missing from the Job Configurator or could not be removed correctly.
- Fixed an issue where pump-supply and billing actions could switch away from the selected vehicle or player.

**Other Changes**

- Fixed an issue where returned or replaced hoses could resume after an earlier connection request completed.
- Fixed an issue where equipment, hydrant, pump, water-monitor and oil-spill interactions stopped working after the target provider restarted.
- Improved tablet invoice direction labels and cleared cached invoice details when billing access is revoked.
- Added a packaged installation checklist with hose, inventory and first-use instructions.

**Changed Files**

- `sky_firejob/INSTALL.md`
- `sky_firejob/README.md`
- `sky_firejob/config/config.lua`
- `sky_firejob/config/locales/*`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/source/*` — delete and reinsert

<update-guide from="1.21.1" resource="sky_firejob" to="1.22.0">
<template v-slot:simplified="">

### 1. Back up and stop

**Database prerequisite for the shared configurator:** when Jobs Base uses `Config.UseIngameConfigurator = true` (the supplied default), this upgrade's primary-group migration requires oxmysql transactions. Install oxmysql for your existing FiveM database and start it before Base. In `sky_base/config/config.lua`, find the existing `sql = "auto"` / `sql = "mysql-async"` entry and set `sql = "oxmysql"`, preserving the same database connection and all data. Then follow the Base and Jobs Base update guides. This requirement applies before the first updated start; disabling automatic schema creation does not replace the transaction requirement.

These steps update **Sky Fire Job 1.21.1 to 1.22.0**. Install **Sky Base 1.52.0** and **Sky Jobs Base 1.55.0** and complete their update guides during the same server update.

Back up the FiveM database and the complete installed resource, including your customized configuration and translations. Keep a copy of the old files until your checks pass. Stop the server before replacing files so saved jobs and active work cannot change during the update. Keep the resource folder names unchanged.

Preserve saved fire stations, missions, reports, vehicles and custom extinguisher mounts. The new rescue-tool default uses equipment taken from a configured fire vehicle; choose the inventory alternative below if you want to retain your current workflow.

### 2. Install the matching files

In your installed `sky_firejob` folder:

1. Delete the old `source/` folder completely, then copy the complete new `source/` folder, including its interface.
2. Copy `fxmanifest.lua`, `INSTALL.md` and `README.md` from the same download.
3. Replace the complete `config/locales/` folder with the one from this download. If you customized translations, copy only your changed wording into the matching entries of the new files and retain every new key.
4. Open your installed `config/config.lua` beside the new copy. Keep your existing stations, vehicles, permissions, rescue items, nozzle choice and other settings. Add the two fields below only when using file-based configuration.

No stream, item-image or audio file changes are introduced by this Fire update. There are no outside-source removals or renames.

### 3. Keep settings and configure the update

**With the default Config.UseJobConfigurator = true:** keep saved `/jobconfig` settings and do not run a settings import or reset. After the updated server starts, open `/jobconfig`, select **Fire Jobs**, then **Vehicle Rescue > General**. Review these two settings before letting players resume rescue work:

- **Take tools from fire vehicles** (`vehicleRescueRequireVehicleTools`) defaults to **enabled**. Firefighters must take and carry one tool from a working fire vehicle listed in the existing `Config.Hose.vehicles` configuration. No rescue-tool inventory item is required in this mode. Disable the switch and save to retain the previous inventory-item workflow.
- **Tool pickup distance** (`vehicleRescueToolPickupDistance`) defaults to **4 metres**. It controls taking, exchanging and returning tools at the fire vehicle. Change it only if needed and save.

Saved overrides remain authoritative. Keep the existing rescue permissions, minigames, window-before-door requirement and vehicle/station definitions.

**With Config.UseJobConfigurator = false:** before starting the resource, open `sky_firejob/config/config.lua` and find its existing `Config.VehicleRescue = {` block. Immediately after the existing `requireOnDuty` line, insert these two lines if missing. Keep your own `requireOnDuty` value and every other field unchanged:

```lua
requireVehicleTools = true,
toolPickupDistance = 4.0,
```

Use `requireVehicleTools = true` for the new vehicle-supplied workflow. To keep the previous inventory behavior, set that one value to `false`; the configured glass hammer and spreader items are then required as before. Keep `toolPickupDistance = 4.0` unless deliberately choosing a different distance. Save and restart for file changes.

In vehicle mode, taking, exchanging and returning tools uses your existing target/radial interaction choice. Leave the fire vehicle, move within pickup distance, then choose **Take glass hammer** or **Take hydraulic spreader**. You can carry one tool at a time. Choose the other tool at the vehicle to exchange it, or **Return rescue tool** to put it away. Cancelling a rescue minigame keeps the carried vehicle tool in your hands.

### 4. Database, items and assets

No Fire SQL migration or manual import is required for this update. Keep existing stations, reports, missions and extinguisher records. Custom extinguisher mounts are reconciled by the resource; do not delete SQL rows or recreate all mounts.

No new inventory item, item image, streamed model, dependency provider or permission is required. Keep all existing item registrations and stock. Vehicle-supplied rescue tools do not consume inventory items; when **Take tools from fire vehicles** is disabled, keep the existing configured `glas_hammer` and `hydrualic_spreader` items available as before.

Keep your current hose-weapon inventory/anticheat compatibility settings. This update does not change the names of either bundled nozzle weapon.

### 5. Start and check the result

Start your framework, database connector and configured inventory, garage, target, phone and other providers first. Start `sky_base` **1.52.0**, then `sky_jobs_base` **1.55.0**, and wait for successful initialization before starting this job. Install only the providers and optional resources your server uses.

Start `sky_firejob` **1.22.0**, then reconnect. Resolve startup errors before reopening the server. Open the Vehicle Rescue settings after this first updated start and save your chosen tool mode before players resume rescue work.

1. Join as an on-duty firefighter and take a working configured fire vehicle. In vehicle-tool mode, take the glass hammer within pickup distance, remove a window on an eligible damaged vehicle, exchange it for the hydraulic spreader at the fire vehicle, and remove the door on that same side. Return the tool afterwards. In inventory mode, perform the same rescue with the configured items in the player's inventory.
2. Take and return a hose. If using the EU nozzle, aim and lower it and check the hose route. With a second player, leave and re-enter streaming range and check that the other firefighter's hose returns correctly.
3. Check the ladder controls of your pump vehicle while its pump behavior holds it stationary. Near a placed hose divider, open the radial valve operation and check a valve.
4. Open the existing custom extinguisher mounts in `/jobconfig` and confirm the saved placements are listed. If testing removal, use a disposable test mount and confirm that its world object and saved entry are removed together.
5. Issue a small targeted Fire invoice and check that it remains assigned to the selected player.

</template>

<template v-slot:prepare="">

**Database prerequisite for the shared configurator:** when Jobs Base uses `Config.UseIngameConfigurator = true` (the supplied default), this upgrade's primary-group migration requires oxmysql transactions. Install oxmysql for your existing FiveM database and start it before Base. In `sky_base/config/config.lua`, find the existing `sql = "auto"` / `sql = "mysql-async"` entry and set `sql = "oxmysql"`, preserving the same database connection and all data. Then follow the Base and Jobs Base update guides. This requirement applies before the first updated start; disabling automatic schema creation does not replace the transaction requirement.

These steps update **Sky Fire Job 1.21.1 to 1.22.0**. Install **Sky Base 1.52.0** and **Sky Jobs Base 1.55.0** and complete their update guides during the same server update.

Back up the FiveM database and the complete installed resource, including your customized configuration and translations. Keep a copy of the old files until your checks pass. Stop the server before replacing files so saved jobs and active work cannot change during the update. Keep the resource folder names unchanged.

Preserve saved fire stations, missions, reports, vehicles and custom extinguisher mounts. The new rescue-tool default uses equipment taken from a configured fire vehicle; choose the inventory alternative below if you want to retain your current workflow.

</template>

<template v-slot:files="">

In your installed `sky_firejob` folder:

1. Delete the old `source/` folder completely, then copy the complete new `source/` folder, including its interface.
2. Copy `fxmanifest.lua`, `INSTALL.md` and `README.md` from the same download.
3. Replace the complete `config/locales/` folder with the one from this download. If you customized translations, copy only your changed wording into the matching entries of the new files and retain every new key.
4. Open your installed `config/config.lua` beside the new copy. Keep your existing stations, vehicles, permissions, rescue items, nozzle choice and other settings. Add the two fields below only when using file-based configuration.

No stream, item-image or audio file changes are introduced by this Fire update. There are no outside-source removals or renames.

</template>

<template v-slot:config="">

**With the default Config.UseJobConfigurator = true:** keep saved `/jobconfig` settings and do not run a settings import or reset. After the updated server starts, open `/jobconfig`, select **Fire Jobs**, then **Vehicle Rescue > General**. Review these two settings before letting players resume rescue work:

- **Take tools from fire vehicles** (`vehicleRescueRequireVehicleTools`) defaults to **enabled**. Firefighters must take and carry one tool from a working fire vehicle listed in the existing `Config.Hose.vehicles` configuration. No rescue-tool inventory item is required in this mode. Disable the switch and save to retain the previous inventory-item workflow.
- **Tool pickup distance** (`vehicleRescueToolPickupDistance`) defaults to **4 metres**. It controls taking, exchanging and returning tools at the fire vehicle. Change it only if needed and save.

Saved overrides remain authoritative. Keep the existing rescue permissions, minigames, window-before-door requirement and vehicle/station definitions.

**With Config.UseJobConfigurator = false:** before starting the resource, open `sky_firejob/config/config.lua` and find its existing `Config.VehicleRescue = {` block. Immediately after the existing `requireOnDuty` line, insert these two lines if missing. Keep your own `requireOnDuty` value and every other field unchanged:

```lua
requireVehicleTools = true,
toolPickupDistance = 4.0,
```

Use `requireVehicleTools = true` for the new vehicle-supplied workflow. To keep the previous inventory behavior, set that one value to `false`; the configured glass hammer and spreader items are then required as before. Keep `toolPickupDistance = 4.0` unless deliberately choosing a different distance. Save and restart for file changes.

In vehicle mode, taking, exchanging and returning tools uses your existing target/radial interaction choice. Leave the fire vehicle, move within pickup distance, then choose **Take glass hammer** or **Take hydraulic spreader**. You can carry one tool at a time. Choose the other tool at the vehicle to exchange it, or **Return rescue tool** to put it away. Cancelling a rescue minigame keeps the carried vehicle tool in your hands.

</template>

<template v-slot:data="">

No Fire SQL migration or manual import is required for this update. Keep existing stations, reports, missions and extinguisher records. Custom extinguisher mounts are reconciled by the resource; do not delete SQL rows or recreate all mounts.

No new inventory item, item image, streamed model, dependency provider or permission is required. Keep all existing item registrations and stock. Vehicle-supplied rescue tools do not consume inventory items; when **Take tools from fire vehicles** is disabled, keep the existing configured `glas_hammer` and `hydrualic_spreader` items available as before.

Keep your current hose-weapon inventory/anticheat compatibility settings. This update does not change the names of either bundled nozzle weapon.

</template>

<template v-slot:verify="">

Start your framework, database connector and configured inventory, garage, target, phone and other providers first. Start `sky_base` **1.52.0**, then `sky_jobs_base` **1.55.0**, and wait for successful initialization before starting this job. Install only the providers and optional resources your server uses.

Start `sky_firejob` **1.22.0**, then reconnect. Resolve startup errors before reopening the server. Open the Vehicle Rescue settings after this first updated start and save your chosen tool mode before players resume rescue work.

1. Join as an on-duty firefighter and take a working configured fire vehicle. In vehicle-tool mode, take the glass hammer within pickup distance, remove a window on an eligible damaged vehicle, exchange it for the hydraulic spreader at the fire vehicle, and remove the door on that same side. Return the tool afterwards. In inventory mode, perform the same rescue with the configured items in the player's inventory.
2. Take and return a hose. If using the EU nozzle, aim and lower it and check the hose route. With a second player, leave and re-enter streaming range and check that the other firefighter's hose returns correctly.
3. Check the ladder controls of your pump vehicle while its pump behavior holds it stationary. Near a placed hose divider, open the radial valve operation and check a valve.
4. Open the existing custom extinguisher mounts in `/jobconfig` and confirm the saved placements are listed. If testing removal, use a disposable test mount and confirm that its world object and saved entry are removed together.
5. Issue a small targeted Fire invoice and check that it remains assigned to the selected player.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-11-03" title="Version 1.21.1" badge="Previous">
<template v-slot:body="">

**Highlights**

- Fixed an issue where a newly created oil spill briefly braked the vehicle that was leaking oil.

**Changed Files**

- `sky_firejob/config/locales/*`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/source/*` — delete and reinsert

<update-guide from="1.21.0" resource="sky_firejob" to="1.21.1">
<template v-slot:simplified="">

### 1. Back up and stop the server

These steps update `sky_firejob` from `1.21.0` to `1.21.1`. Complete the earlier update instructions first if your installed version is older.

1. Download and extract `sky_firejob 1.21.1` on your computer.
2. Back up the installed resource folder, customized configuration and translations, and the game database. Keep the backup until your checks pass.
3. Finish active interactions and stop the server before replacing files.

### 2. Install the matching files

1. Delete the installed `source/` folder and copy the complete new `source/` folder into its place, including all interface files.
2. Replace `fxmanifest.lua` from the same download.
3. Replace the complete `config/locales/` folder. Transfer only your custom wording into matching new entries; keep every supplied key and language file.

Keep the existing configuration, streamed assets and inventory files.

### 3. Keep settings and apply the required configuration

No new configuration value or settings import is required. Keep existing oil-spill, vehicle-drag and skid settings. The oil contact effect no longer presses or releases the vehicle brake; oil spreading and the existing loss of traction remain active.

With `/jobconfig`, retain saved Fire settings. With `Config.UseJobConfigurator = false`, keep your current `config/config.lua`. A previously customized `OilSpills.vehicleDrag.brakeMs` value is no longer used and can be removed from your own override; do not reset or import all settings to remove it.

### 4. Preserve data, items and assets

No SQL import, schema change, inventory item, image, streamed model or provider change is required. Preserve existing incidents, vehicle definitions and saved settings.

### 5. Start and check the result

For this coordinated update, start the database connector, framework and configured providers, then Sky Base `1.51.1`, Jobs Base `1.54.1` and `sky_firejob 1.21.1`. Reconnect players.

In a safe test area, check a vehicle that is leaking oil: creating or contacting a spill should not apply a short forced brake. Confirm that the existing skid and oil-spreading effects still work. Keep the current vehicle and oil-spill settings.

</template>

<template v-slot:prepare="">

These steps update `sky_firejob` from `1.21.0` to `1.21.1`. Complete the earlier update instructions first if your installed version is older.

1. Download and extract `sky_firejob 1.21.1` on your computer.
2. Back up the installed resource folder, customized configuration and translations, and the game database. Keep the backup until your checks pass.
3. Finish active interactions and stop the server before replacing files.

</template>

<template v-slot:files="">

1. Delete the installed `source/` folder and copy the complete new `source/` folder into its place, including all interface files.
2. Replace `fxmanifest.lua` from the same download.
3. Replace the complete `config/locales/` folder. Transfer only your custom wording into matching new entries; keep every supplied key and language file.

Keep the existing configuration, streamed assets and inventory files.

</template>

<template v-slot:config="">

No new configuration value or settings import is required. Keep existing oil-spill, vehicle-drag and skid settings. The oil contact effect no longer presses or releases the vehicle brake; oil spreading and the existing loss of traction remain active.

With `/jobconfig`, retain saved Fire settings. With `Config.UseJobConfigurator = false`, keep your current `config/config.lua`. A previously customized `OilSpills.vehicleDrag.brakeMs` value is no longer used and can be removed from your own override; do not reset or import all settings to remove it.

</template>

<template v-slot:data="">

No SQL import, schema change, inventory item, image, streamed model or provider change is required. Preserve existing incidents, vehicle definitions and saved settings.

</template>

<template v-slot:verify="">

For this coordinated update, start the database connector, framework and configured providers, then Sky Base `1.51.1`, Jobs Base `1.54.1` and `sky_firejob 1.21.1`. Reconnect players.

In a safe test area, check a vehicle that is leaking oil: creating or contacting a spill should not apply a short forced brake. Confirm that the existing skid and oil-spreading effects still work. Keep the current vehicle and oil-spill settings.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-11-02" title="Version 1.21.0" badge="Previous">
<template v-slot:body="">

**Highlights**

- Improved water and foam selection so all hand hoses connected to the same vehicle use the operator's current choice, including divider branches.
- Fixed an issue where vehicle rescue damage could return after another resource repaired the vehicle's windows or doors.

**Notable Changes**

- Fixed an issue where other players could not see the rescue tool held by a firefighter.
- Fixed an issue where a correctly supplied divider hose could fail to extinguish fires.
- Fixed an issue where a hand hose kept spraying locally after its server-side supply or active spray had ended.
- Fixed an issue where an eligible Dispatch response plan bypassed an automatic mission's configured minimum number of on-duty firefighters.
- Fixed an issue where cancelled missions remained in the active mission list or returned after a delayed update.
- Improved record printing feedback to explain unavailable printers, inventory limitations, access restrictions and full queues.

**Other Changes**

- Improved citizen and patient document previews and printouts to include their saved phone number.
- Improved asset previews so the full image fits inside its tile, and localized empty category search results.
- Reduced repeated fire-growth updates, water-monitor trajectory calculations and settings preparation without changing their configured timing.
- Reduced obsolete tablet radio requests when the interface changes quickly.

**Changed Files**

- `sky_firejob/config/locales/*`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/source/*` — delete and reinsert

<update-guide from="1.20.0" resource="sky_firejob" to="1.21.0">
<template v-slot:simplified="">

### 1. Back up and stop the server

These steps update `sky_firejob` from `1.20.0` to `1.21.0`. If you use an older release, complete its earlier update instructions first.

1. Download `1.21.0` and extract the ZIP on your computer.
2. Back up your installed `sky_firejob` folder, custom configuration/translations and game database. Keep the backup until your checks pass.
3. Stop the server before replacing files.

Complete the [Base 1.51.0 update](/docs/base/changelog) and [Jobs Base 1.54.0 update](/docs/base/jobs-base/changelog) as well. Follow their own database and inventory steps separately.

### 2. Install the matching files

Use files from the same `1.21.0` download throughout. The paths below are inside your installed `sky_firejob` folder.

1. Delete the old `source/` folder and copy the complete new `source/` folder into its place, including its interface files.
2. Replace `fxmanifest.lua` with the matching new file.
3. Replace the complete `config/locales/` folder. Open any customized language file from your backup beside its new version and transfer only your edited wording into matching entries. Keep every supplied key and file.

Keep your existing `config/config.lua`, `config/init.lua`, vehicle definitions, custom models and other configuration files. This update adds no Fire configuration entries.

### 3. Keep your settings

**With /jobconfig:** keep your saved Fire jobs, automatic mission settings, Dispatch plans, hose and pump settings. No import or reset is required. Do not run `/jobconfigimport sky_firejob` just to install this update.

**With Config.UseJobConfigurator = false:** keep your current `sky_firejob/config/config.lua` unchanged. There are no new, removed or renamed Fire options to copy.

Water/foam selection is now shared by all hand hoses supplied by the same vehicle, including divider branches. An operator's change also applies to hoses already spraying; another vehicle keeps its own selection. Water remains the initial choice unless the vehicle is configured with only a foam tank. Existing tank capacities, pump pressure, outlets and supply requirements still apply.

An automatic mission now needs both its configured minimum on-duty crew and, when enabled for that mission, an eligible Dispatch response plan. Police or other jobs receiving the alert do not replace the mission's selected crew. Keep your existing minimum unless you intend to change that gameplay rule.

### 4. Keep existing database, items and assets

No new Fire SQL, inventory item, inventory image, streamed model, provider or permission migration is required. Keep saved missions, incidents, vehicle equipment, hydrants, extinguisher data and other existing records. Do not run a SQL reset or reimport for this Fire update.

The shared record-printing messages come from the matching Jobs Base update. Its separate printing-item and database instructions still apply to servers enabling that shared feature.

### 5. Start and check the result

1. Start your framework, database connector and selected providers, then `sky_base 1.51.0`, `sky_jobs_base 1.54.0` and `sky_firejob 1.21.0`. Wait for startup to complete and resolve the first reported error before continuing.
2. Confirm that Fire reports version `1.21.0`, then reconnect players so the new interface loads.
3. Check your saved Fire jobs and missions. Cancel a test mission and confirm that it disappears from the active list. For automatic missions, confirm that the selected crew meets the saved minimum and any required Dispatch plan is eligible.
4. On a configured vehicle, connect and supply a hand hose or divider branch. Switch water/foam where supported and confirm that connected hand hoses follow the same choice; check stopping the supply too. Try vehicle rescue with another player, then repair that test vehicle and confirm that the repaired doors/windows stay repaired.
5. If you use records and printers, open a saved record and check its document preview and normal printing flow before reopening the server to everyone.

</template>

<template v-slot:prepare="">

These steps update `sky_firejob` from `1.20.0` to `1.21.0`. If you use an older release, complete its earlier update instructions first.

1. Download `1.21.0` and extract the ZIP on your computer.
2. Back up your installed `sky_firejob` folder, custom configuration/translations and game database. Keep the backup until your checks pass.
3. Stop the server before replacing files.

Complete the [Base 1.51.0 update](/docs/base/changelog) and [Jobs Base 1.54.0 update](/docs/base/jobs-base/changelog) as well. Follow their own database and inventory steps separately.

</template>

<template v-slot:files="">

Use files from the same `1.21.0` download throughout. The paths below are inside your installed `sky_firejob` folder.

1. Delete the old `source/` folder and copy the complete new `source/` folder into its place, including its interface files.
2. Replace `fxmanifest.lua` with the matching new file.
3. Replace the complete `config/locales/` folder. Open any customized language file from your backup beside its new version and transfer only your edited wording into matching entries. Keep every supplied key and file.

Keep your existing `config/config.lua`, `config/init.lua`, vehicle definitions, custom models and other configuration files. This update adds no Fire configuration entries.

</template>

<template v-slot:config="">

**With /jobconfig:** keep your saved Fire jobs, automatic mission settings, Dispatch plans, hose and pump settings. No import or reset is required. Do not run `/jobconfigimport sky_firejob` just to install this update.

**With Config.UseJobConfigurator = false:** keep your current `sky_firejob/config/config.lua` unchanged. There are no new, removed or renamed Fire options to copy.

Water/foam selection is now shared by all hand hoses supplied by the same vehicle, including divider branches. An operator's change also applies to hoses already spraying; another vehicle keeps its own selection. Water remains the initial choice unless the vehicle is configured with only a foam tank. Existing tank capacities, pump pressure, outlets and supply requirements still apply.

An automatic mission now needs both its configured minimum on-duty crew and, when enabled for that mission, an eligible Dispatch response plan. Police or other jobs receiving the alert do not replace the mission's selected crew. Keep your existing minimum unless you intend to change that gameplay rule.

</template>

<template v-slot:data="">

No new Fire SQL, inventory item, inventory image, streamed model, provider or permission migration is required. Keep saved missions, incidents, vehicle equipment, hydrants, extinguisher data and other existing records. Do not run a SQL reset or reimport for this Fire update.

The shared record-printing messages come from the matching Jobs Base update. Its separate printing-item and database instructions still apply to servers enabling that shared feature.

</template>

<template v-slot:verify="">

1. Start your framework, database connector and selected providers, then `sky_base 1.51.0`, `sky_jobs_base 1.54.0` and `sky_firejob 1.21.0`. Wait for startup to complete and resolve the first reported error before continuing.
2. Confirm that Fire reports version `1.21.0`, then reconnect players so the new interface loads.
3. Check your saved Fire jobs and missions. Cancel a test mission and confirm that it disappears from the active list. For automatic missions, confirm that the selected crew meets the saved minimum and any required Dispatch plan is eligible.
4. On a configured vehicle, connect and supply a hand hose or divider branch. Switch water/foam where supported and confirm that connected hand hoses follow the same choice; check stopping the supply too. Try vehicle rescue with another player, then repair that test vehicle and confirm that the repaired doors/windows stay repaired.
5. If you use records and printers, open a saved record and check its document preview and normal printing flow before reopening the server to everyone.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-10-27" title="Version 1.20.0">
<template v-slot:body="">

**Highlights**

- Added optional weapon-triggered Sky fires with an editable weapon allowlist, disabled by default.
- Added automatic mission rotation so eligible missions can run once per round before repeating.

**Notable Changes**

- Fixed an issue where mask overlays covered smoke-poisoning warnings.
- Fixed an issue where partial breathing protection suppressed coughing despite remaining toxic exposure.
- Fixed an issue where a fresh manual SQL import stopped before Jobs Base had created its shared settings table.

**Other Changes**

- Improved fire-gear status information to distinguish recognized equipment from effective breathing protection.
- Optimized extinguisher discovery by avoiding position checks for unrelated world objects.

**Changed Files**

- `sky_firejob/README.md`
- `sky_firejob/config/config.lua`
- `sky_firejob/config/locales/*`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/import.sql`
- `sky_firejob/source/*` — delete and reinsert

<update-guide from="1.19.0" resource="sky_firejob" to="1.20.0">
<template v-slot:simplified="">

### 1. Back up and stop the server

These steps update `sky_firejob` from `1.19.0` to `1.20.0`. Complete earlier update instructions first if you are on an older release.

1. Download `1.20.0` and extract it on your computer.
2. Back up your installed `sky_firejob` folder, custom configuration/translations and game database. Keep the backup until your checks pass.
3. Stop the server before replacing files.

Also complete the [Base 1.50.0 update](/docs/base/changelog) and [Jobs Base 1.53.0 update](/docs/base/jobs-base/changelog); their database and inventory steps are separate.

### 2. Install the matching files

Use files from the same `1.20.0` download throughout. Paths below are inside your installed `sky_firejob` folder.

1. Delete the old `source/` folder and copy the complete new `source/` folder into its place, including its interface files.
2. Replace `fxmanifest.lua` with the matching new file.
3. Replace the complete `config/locales/` folder. Transfer only your custom wording into matching new entries from your backup; retain every new key and file.

Replace `import.sql` with the file from this same download so future manual setup uses the corrected import. Replacing this file does not mean executing it: an ordinary 1.19.0 → 1.20.0 update needs no new SQL run. Keep your customized configuration files and make only the settings changes in the next step.

### 3. Keep settings and configure optional features

**With /jobconfig:** select Fire Jobs. Under **Fire → Weapon fires**, the new `fireWeaponIgnitionEnabled` switch defaults to `false` and `fireWeaponIgnitionWeapons` defaults to `WEAPON_MOLOTOV`. Keep it disabled unless you want weapon-triggered Sky fires. Edit the weapon list before enabling and save. An empty list permits none. Disabling discards pending ignitions but does not remove existing fires. Native GTA flames/damage, mission fires and other ignition features remain separate.

Under **Automatic Missions**, choose **Mission selection** (`scenarioRandomSelectionMode`): **Random rotation** (`rotation`, the new default) uses each currently eligible mission before repeating; **Pure random** (`random`) allows repeats. Keep your existing automatic-enable, interval, chance and mission eligibility choices. Failed starts do not count; restarting Fire resets rotation history.

**With Config.UseJobConfigurator = false:** open `sky_firejob/config/config.lua`. Inside the existing `Config.FireSystem` table, add this block after `syncDistance`, keeping the surrounding settings:

```lua
molotovIgnition = {
    enabled = false,
    weapons = { "WEAPON_MOLOTOV" }
},
```

If you already customized this block, retain its other options. Replace a legacy singular `weapon = "..."` entry with `weapons = { "..." }` containing that same chosen weapon; an absent list can still import the old singular value. In the existing `Config.FireScenarioCreator.randomTrigger` block, insert `selectionMode = "rotation",` after `enabled`; use `"random"` to retain repeat-permitted selection. No other file-owned value needs changing.

Saved panel settings override imported Lua values. Do not run `/jobconfigimport sky_firejob` just to update the resource.

### 4. Database, items and assets

No new Fire schema, inventory item, image or streamed model is required. Keep saved missions, incidents, vehicle equipment, hydrants and extinguisher data. No SQL reset or reimport is needed for these changes.

**Only for a fresh manual database setup or a previously aborted fresh import:** if automatic queries are enabled, keep them enabled and start Jobs Base before Fire so each resource initializes its own tables. If `Config.AutoExecuteQuery = false`, import Jobs Base's supplied `import.sql` first, then this release's Fire `import.sql`, into the same game database. The corrected Fire import also runs when the shared Jobs Base settings table is not present; it skips only the optional upgrade of old saved hydrant settings in that case. Jobs Base still owns and creates its own shared tables. Existing saved hydrant overrides are preserved and the unit conversion is not repeated after it has been applied. Do not clear existing tables to repair an interrupted import.

### 5. Start and check the result

Start the framework, database connector and selected providers, then `sky_base 1.50.0`, `sky_jobs_base 1.53.0` and `sky_firejob 1.20.0`. Confirm the version and reconnect players.

Check a saved mission and your automatic selection mode. If enabling weapon fires, test only the chosen weapons on your test server. Check that a smoke warning remains visible over the mask and that partial protection still permits symptoms when exposure reaches the player.

If Fire Dispatch reports **Center missing**, open `/jobconfig`, select the actual Fire job and its **Dispatch** page, choose **Open dispatch centers**, add that exact internal job name to an enabled center's **Covered jobs**, and save. Keep all intended recipients of one incident covered by the same center. Reopen the Fire page, go on duty, join a virtual unit, choose an available FMS status and start a new mission. Keep the configured radio channels, or follow the optional Shared Operations steps in the Jobs Base guide.

</template>

<template v-slot:prepare="">

These steps update `sky_firejob` from `1.19.0` to `1.20.0`. Complete earlier update instructions first if you are on an older release.

1. Download `1.20.0` and extract it on your computer.
2. Back up your installed `sky_firejob` folder, custom configuration/translations and game database. Keep the backup until your checks pass.
3. Stop the server before replacing files.

Also complete the [Base 1.50.0 update](/docs/base/changelog) and [Jobs Base 1.53.0 update](/docs/base/jobs-base/changelog); their database and inventory steps are separate.

</template>

<template v-slot:files="">

Use files from the same `1.20.0` download throughout. Paths below are inside your installed `sky_firejob` folder.

1. Delete the old `source/` folder and copy the complete new `source/` folder into its place, including its interface files.
2. Replace `fxmanifest.lua` with the matching new file.
3. Replace the complete `config/locales/` folder. Transfer only your custom wording into matching new entries from your backup; retain every new key and file.

Replace `import.sql` with the file from this same download so future manual setup uses the corrected import. Replacing this file does not mean executing it: an ordinary 1.19.0 → 1.20.0 update needs no new SQL run. Keep your customized configuration files and make only the settings changes in the next step.

</template>

<template v-slot:config="">

**With /jobconfig:** select Fire Jobs. Under **Fire → Weapon fires**, the new `fireWeaponIgnitionEnabled` switch defaults to `false` and `fireWeaponIgnitionWeapons` defaults to `WEAPON_MOLOTOV`. Keep it disabled unless you want weapon-triggered Sky fires. Edit the weapon list before enabling and save. An empty list permits none. Disabling discards pending ignitions but does not remove existing fires. Native GTA flames/damage, mission fires and other ignition features remain separate.

Under **Automatic Missions**, choose **Mission selection** (`scenarioRandomSelectionMode`): **Random rotation** (`rotation`, the new default) uses each currently eligible mission before repeating; **Pure random** (`random`) allows repeats. Keep your existing automatic-enable, interval, chance and mission eligibility choices. Failed starts do not count; restarting Fire resets rotation history.

**With Config.UseJobConfigurator = false:** open `sky_firejob/config/config.lua`. Inside the existing `Config.FireSystem` table, add this block after `syncDistance`, keeping the surrounding settings:

```lua
molotovIgnition = {
    enabled = false,
    weapons = { "WEAPON_MOLOTOV" }
},
```

If you already customized this block, retain its other options. Replace a legacy singular `weapon = "..."` entry with `weapons = { "..." }` containing that same chosen weapon; an absent list can still import the old singular value. In the existing `Config.FireScenarioCreator.randomTrigger` block, insert `selectionMode = "rotation",` after `enabled`; use `"random"` to retain repeat-permitted selection. No other file-owned value needs changing.

Saved panel settings override imported Lua values. Do not run `/jobconfigimport sky_firejob` just to update the resource.

</template>

<template v-slot:data="">

No new Fire schema, inventory item, image or streamed model is required. Keep saved missions, incidents, vehicle equipment, hydrants and extinguisher data. No SQL reset or reimport is needed for these changes.

**Only for a fresh manual database setup or a previously aborted fresh import:** if automatic queries are enabled, keep them enabled and start Jobs Base before Fire so each resource initializes its own tables. If `Config.AutoExecuteQuery = false`, import Jobs Base's supplied `import.sql` first, then this release's Fire `import.sql`, into the same game database. The corrected Fire import also runs when the shared Jobs Base settings table is not present; it skips only the optional upgrade of old saved hydrant settings in that case. Jobs Base still owns and creates its own shared tables. Existing saved hydrant overrides are preserved and the unit conversion is not repeated after it has been applied. Do not clear existing tables to repair an interrupted import.

</template>

<template v-slot:verify="">

Start the framework, database connector and selected providers, then `sky_base 1.50.0`, `sky_jobs_base 1.53.0` and `sky_firejob 1.20.0`. Confirm the version and reconnect players.

Check a saved mission and your automatic selection mode. If enabling weapon fires, test only the chosen weapons on your test server. Check that a smoke warning remains visible over the mask and that partial protection still permits symptoms when exposure reaches the player.

If Fire Dispatch reports **Center missing**, open `/jobconfig`, select the actual Fire job and its **Dispatch** page, choose **Open dispatch centers**, add that exact internal job name to an enabled center's **Covered jobs**, and save. Keep all intended recipients of one incident covered by the same center. Reopen the Fire page, go on duty, join a virtual unit, choose an available FMS status and start a new mission. Keep the configured radio channels, or follow the optional Shared Operations steps in the Jobs Base guide.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-10-22" title="Version 1.19.0">
<template v-slot:body="">

**Highlights**

- Added multiple named water cannons on a supported vehicle with separate outlets, HUD selection and different crew operators.
- Improved selected-object targets throughout hose, pump, monitor, extinguisher, rescue, oil cleanup and fallen-tree work.

**Notable Changes**

- Fixed an issue where configured map hydrants were missed by the radial menu or supply-line connection.
- Fixed an issue where an Activities race kart could trigger player entrapment when using the compatible Activities integration.
- Improved recovery of Scenario Hub reads during transient API failures.
- Improved personal radio push-to-talk while using the tablet.

**Other Changes**

- Reduced repeated synchronization work for unchanged extinguishers, distant empty mounts and hydrant discovery.
- Improved Fire feature grouping, shared forms, billing documents and asset selection.
- Added a compatible inventory icon filename for the existing hydraulic spreader item.

**Changed Files**

- `sky_firejob/README.md`
- `sky_firejob/config/inventory/hydrualic_spreader.png`
- `sky_firejob/config/locales/*`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/source/*` — delete and reinsert

<update-guide from="1.18.0" resource="sky_firejob" to="1.19.0">
<template v-slot:simplified="">

### 1. Back up and stop the server

These steps update `sky_firejob` from `1.18.0` to `1.19.0`. If you are on an older version, complete its earlier update steps first.

1. Download `1.19.0` and extract the ZIP on your computer.
2. Make a full backup of your server files and game database. Also keep a separate copy of the installed `sky_firejob` folder.
3. Stop the server before replacing files. Put away equipped custom weapons first. Keep the backup until the update has been checked.

Also complete the [Base update](/docs/base/changelog) and [Jobs Base update](/docs/base/jobs-base/changelog) for your installed jobs. They contain the library, database and inventory steps shared by these jobs.

### 2. Copy the new files

Use the files from the `1.19.0` download throughout these steps. All paths below are inside your installed `sky_firejob` folder.

1. Delete the old `source/` folder. Copy the complete new `source/` folder into its place, including its interface files.
2. Replace `fxmanifest.lua` with the file from the same download.
3. Replace the complete `config/locales/` folder with the new one. If you changed any wording, open the backed-up language file beside the new file and copy your edited text into the matching entries. Keep the new translation keys and folders.
4. Keep your existing `config/config.lua`; make only the settings changes described in step 3 below. Do not overwrite your configured jobs or locations with the download's defaults.

Copy the new `README.md` and `config/inventory/hydrualic_spreader.png` to the same paths. Step 4 explains where to copy the inventory icon.

### 3. Check your settings

**No settings change is required for an existing Fire installation.** Keep your current `config/config.lua`, `/jobconfig` settings, hydrant models, connection distance and single-cannon vehicle setup. No default import or API credential change is needed.

**Optional: several cannons on one vehicle.** Only configure this if your actual vehicle has suitable cannon bones. Open `/jobconfig` → Fire Jobs → Fire → Extinguishing → Vehicle water cannon and add the intended cannons with distinct IDs and labels. Keep the existing cannon's ID as `deckGun`. Use 1–48 letters, digits, underscores or hyphens; IDs are case-sensitive and must be unique for each vehicle model.

The vehicle also needs its tank, pump panel, intake and outlets configured under Pump panel → Vehicles. Follow [Multiple vehicle water cannons](/docs/jobs/firejob/features/fire-and-hose-system#multiple-vehicle-water-cannons) for the complete setup, including Lua configuration if you do not use `/jobconfig`. Do not copy example bone names into a production vehicle.

For a configured vehicle, enable its pump, supply water, build pressure and open the intended outlet. Hold the configured HUD cursor key (default Left Ctrl), select the cannon and spray with the configured key (default right mouse). Release and press spray again after switching. Each outlet has one operator.

**Only if using Activities race karts:** the kart exclusion requires a running compatible `sky_activities` integration. This Fire update does not supply a new Activities package.

### 4. Update database, items and models

No Fire SQL, new inventory ID, streamed model or permission migration is required. Keep existing hose/pump/monitor and rescue registrations. The legacy item ID `hydrualic_spreader` remains unchanged for compatibility. Copy the newly supplied alias `sky_firejob/config/inventory/hydrualic_spreader.png` into the active inventory image directory as `hydrualic_spreader.png` so inventories using the item name find its icon. The original `hydraulic_spreader.png` is retained. An existing ox_inventory `client = { image = "hydraulic_spreader.png" }` mapping remains valid. This is a compatible image addition, not an item rename or saved-data migration.

### 5. Start the server and check

1. Finish the file copies, required Lua edits and database steps, then start the server. Start the framework, database connector and your selected inventory/weather/phone/banking/voice/key providers first. Start `sky_base 1.48.0`, then `sky_jobs_base 1.51.0`, then the installed jobs. Wait for database updates to complete. If used together, start DOJ `0.6.0` before Police `1.40.0`, and Ambulance `2.47.0` before Crime `0.11.0`.
2. Check the server console for startup or database errors. If an error appears, resolve the first error before testing further. Check that this resource reports version `1.19.0`.
3. Reconnect so the new interface and models load. If step 3 listed in-game settings, open the named configurator, make those changes and save. Then check your saved jobs and the features you use before reopening the server to everyone.

**What to check for this resource:** Connect a supply line at a normal hydrant and any custom mapped hydrants you use. Check water supply, disconnect and cancellation. Try the hose/pump/rescue actions you normally use. If you configured several cannons, check each outlet, switching and two crew members on your actual vehicle.

</template>

<template v-slot:prepare="">

These steps update `sky_firejob` from `1.18.0` to `1.19.0`. If you are on an older version, complete its earlier update steps first.

1. Download `1.19.0` and extract the ZIP on your computer.
2. Make a full backup of your server files and game database. Also keep a separate copy of the installed `sky_firejob` folder.
3. Stop the server before replacing files. Put away equipped custom weapons first. Keep the backup until the update has been checked.

Also complete the [Base update](/docs/base/changelog) and [Jobs Base update](/docs/base/jobs-base/changelog) for your installed jobs. They contain the library, database and inventory steps shared by these jobs.

</template>

<template v-slot:files="">

Use the files from the `1.19.0` download throughout these steps. All paths below are inside your installed `sky_firejob` folder.

1. Delete the old `source/` folder. Copy the complete new `source/` folder into its place, including its interface files.
2. Replace `fxmanifest.lua` with the file from the same download.
3. Replace the complete `config/locales/` folder with the new one. If you changed any wording, open the backed-up language file beside the new file and copy your edited text into the matching entries. Keep the new translation keys and folders.
4. Keep your existing `config/config.lua`; make only the settings changes described in step 3 below. Do not overwrite your configured jobs or locations with the download's defaults.

Copy the new `README.md` and `config/inventory/hydrualic_spreader.png` to the same paths. Step 4 explains where to copy the inventory icon.

</template>

<template v-slot:config="">

**No settings change is required for an existing Fire installation.** Keep your current `config/config.lua`, `/jobconfig` settings, hydrant models, connection distance and single-cannon vehicle setup. No default import or API credential change is needed.

**Optional: several cannons on one vehicle.** Only configure this if your actual vehicle has suitable cannon bones. Open `/jobconfig` → Fire Jobs → Fire → Extinguishing → Vehicle water cannon and add the intended cannons with distinct IDs and labels. Keep the existing cannon's ID as `deckGun`. Use 1–48 letters, digits, underscores or hyphens; IDs are case-sensitive and must be unique for each vehicle model.

The vehicle also needs its tank, pump panel, intake and outlets configured under Pump panel → Vehicles. Follow [Multiple vehicle water cannons](/docs/jobs/firejob/features/fire-and-hose-system#multiple-vehicle-water-cannons) for the complete setup, including Lua configuration if you do not use `/jobconfig`. Do not copy example bone names into a production vehicle.

For a configured vehicle, enable its pump, supply water, build pressure and open the intended outlet. Hold the configured HUD cursor key (default Left Ctrl), select the cannon and spray with the configured key (default right mouse). Release and press spray again after switching. Each outlet has one operator.

**Only if using Activities race karts:** the kart exclusion requires a running compatible `sky_activities` integration. This Fire update does not supply a new Activities package.

</template>

<template v-slot:data="">

No Fire SQL, new inventory ID, streamed model or permission migration is required. Keep existing hose/pump/monitor and rescue registrations. The legacy item ID `hydrualic_spreader` remains unchanged for compatibility. Copy the newly supplied alias `sky_firejob/config/inventory/hydrualic_spreader.png` into the active inventory image directory as `hydrualic_spreader.png` so inventories using the item name find its icon. The original `hydraulic_spreader.png` is retained. An existing ox_inventory `client = { image = "hydraulic_spreader.png" }` mapping remains valid. This is a compatible image addition, not an item rename or saved-data migration.

</template>

<template v-slot:verify="">

1. Finish the file copies, required Lua edits and database steps, then start the server. Start the framework, database connector and your selected inventory/weather/phone/banking/voice/key providers first. Start `sky_base 1.48.0`, then `sky_jobs_base 1.51.0`, then the installed jobs. Wait for database updates to complete. If used together, start DOJ `0.6.0` before Police `1.40.0`, and Ambulance `2.47.0` before Crime `0.11.0`.
2. Check the server console for startup or database errors. If an error appears, resolve the first error before testing further. Check that this resource reports version `1.19.0`.
3. Reconnect so the new interface and models load. If step 3 listed in-game settings, open the named configurator, make those changes and save. Then check your saved jobs and the features you use before reopening the server to everyone.

**What to check for this resource:** Connect a supply line at a normal hydrant and any custom mapped hydrants you use. Check water supply, disconnect and cancellation. Try the hose/pump/rescue actions you normally use. If you configured several cannons, check each outlet, switching and two crew members on your actual vehicle.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-10-14" title="Version 1.18.0">
<template v-slot:body="">

**Highlights**

- Improved the EU hose-nozzle grip and routed the hose under the right arm while aiming and moving.
- Updated the bundled fire and rescue translations, including the remaining Portuguese HUD and editor text.

**Notable Changes**

- Fixed an issue where translated icon names caused fire-service radial actions to lose their icons.
- Improved Scenario Hub connection errors so server owners can see the reason a request failed.
- Optimized fire-vehicle initialization by skipping checks for unrelated entities.
- Improved invoice recipient selection with nearby player names and distances while preserving the invoice draft when the list updates.
- Fixed an issue where external billing providers displayed payment controls intended for Sky Billing.
- Improved tablet navigation and forms with consistent headers, clearer labels and better keyboard focus.

**Other Changes**

- Improved the appearance of calendar popups inside tablet dialogs.

**Changed Files**

- `sky_firejob/config/locales/*`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/meta/eu_hose_clip_sets.meta`
- `sky_firejob/meta/weaponanimations.meta`
- `sky_firejob/source/*` — delete and reinsert
- `sky_firejob/stream/sky_fire_hose_eu.ycd`
- `sky_firejob/stream/w_am_hohlstrahlrohr.ydr`

<update-guide from="1.17.0" resource="sky_firejob" to="1.18.0">
<template v-slot:simplified="">

1. **Prepare**

These instructions cover `sky_firejob` `1.17.0` → `1.18.0`. Complete applicable earlier migrations first if you are upgrading from an older version. Back up the database, resources, custom configuration/translations and saved jobs, roles, locations and `/jobconfig` data. Test on staging and stop the server before replacing files. Start the framework, database connector and selected inventory, phone, banking and UI providers first, then sky_base 1.47.0 and sky_jobs_base 1.50.0, followed by the installed job resources. If you use DOJ with Police, start DOJ 0.5.0 before Police 1.39.0. If you use the Crime medical integration, start Ambulance 2.46.0 before Crime 0.10.0. Mechanic 1.36.0 and Fire 1.18.0 follow both libraries. Include only resources you have installed.

1. **Replace files**

Use the complete `1.18.0` customer package. Delete the entire `sky_firejob/source/` folder and insert the new one. Replace `sky_firejob/fxmanifest.lua` from the same download; do not merge old generated interface or bootstrap files. Refresh the complete `sky_firejob/config/locales/` tree and merge custom translations without restoring an older dictionary. Preserve the selected `locale` value in `sky_base/config/config.lua`.

Install the new `sky_firejob/meta/eu_hose_clip_sets.meta` and replace `sky_firejob/meta/weaponanimations.meta`. Add `sky_firejob/stream/sky_fire_hose_eu.ycd` and replace `sky_firejob/stream/w_am_hohlstrahlrohr.ydr`. These two meta files, animation, nozzle model, manifest and complete source must come from the same 1.18.0 package. Preserve unrelated custom models and do not copy development Blender/storage files. Install the matching Jobs Base 1.50.0 locale packs as part of the Jobs Base update.

1. **Merge settings**

No Fire configuration option, shipped default or `/jobconfig` key is added, removed or renamed from 1.17.0. Preserve `config/config.lua`, your hose vehicle setup, response/reward settings and custom integrations. The supplied `Config.Hose.nozzleModel = "normal"` is unchanged; the EU grip is used by the existing `"hohlstrahlrohr"` selection. Keep your chosen nozzle; installing the assets does not change the selection.

With `Config.UseJobConfigurator = true`, active managed values remain shipped defaults plus your saved `/jobconfig` overrides. Do not reset jobs, grades, locations, permissions or feature settings, and do not import plaintext as a routine update step. With the configurator disabled, your existing plaintext values remain active. The Scenario Hub error improvement requires no new key, secret or endpoint setting.

Refresh the complete gameplay locale tree and merge only your own text changes. FireRadial and OilSpills `icon`/`*Icon` values are technical icon identifiers such as `Waves`, `Plug`, `Unplug` and `Brush`; retain their exact supplied spelling in every language.

Optional profiling is disabled by default. If support requests a recording, put `setr sky_profiler 1` in `server.cfg` before the Sky `ensure` lines and perform a full server restart. In the server console, run `profiler record 1000`, wait for `profiler status` to show completion, then run `profiler saveJSON sky-release-20261014.json`; choose a new filename for each recording. Disable it with `setr sky_profiler 0` and another full server restart. This is not a `/jobconfig` setting. No recording or upload starts automatically.

1. **Database, items and assets**

**Database:** No new Fire table, column or manual SQL migration is introduced from 1.17.0. Preserve incidents, reports and saved settings.

**Items and permissions:** No new inventory definition, image registration or permission is required.

**Streamed assets:** Add `sky_firejob/stream/sky_fire_hose_eu.ycd` and replace `sky_firejob/stream/w_am_hohlstrahlrohr.ydr`. Install `sky_firejob/meta/eu_hose_clip_sets.meta`, `sky_firejob/meta/weaponanimations.meta` and the matching manifest together; the manifest registers the new animation clip set. Installing only the nozzle model is incomplete. No non-source removal or rename is needed.

1. **Restart and check**

Perform a full server restart after all replacements and migrations so manifests and file lists reload, then reconnect clients. Start the framework, database connector and selected inventory, phone, banking and UI providers first, then sky_base 1.47.0 and sky_jobs_base 1.50.0, followed by the installed job resources. If you use DOJ with Police, start DOJ 0.5.0 before Police 1.39.0. If you use the Crime medical integration, start Ambulance 2.46.0 before Crime 0.10.0. Mechanic 1.36.0 and Fire 1.18.0 follow both libraries. Include only resources you have installed. Check the actual installed versions and the first startup/database error before testing.

Reconnect after the full restart. If the older nozzle animation remains cached, disconnect and reconnect before comparing the grip. On a staging setup using `hohlstrahlrohr`, check idle, walking, aiming and spraying, including the hose route below the right arm. Keep the normal nozzle selection unchanged if that is your chosen setup. Open fire-service radial actions in your chosen language and verify their icons. Open Reports, File Explorer and nearby-player invoicing. If the Scenario Hub cannot connect, inspect its first failure log; keep signing secrets and credentials private.

</template>

<template v-slot:prepare="">

These instructions cover `sky_firejob` `1.17.0` → `1.18.0`. Complete applicable earlier migrations first if you are upgrading from an older version. Back up the database, resources, custom configuration/translations and saved jobs, roles, locations and `/jobconfig` data. Test on staging and stop the server before replacing files. Start the framework, database connector and selected inventory, phone, banking and UI providers first, then sky_base 1.47.0 and sky_jobs_base 1.50.0, followed by the installed job resources. If you use DOJ with Police, start DOJ 0.5.0 before Police 1.39.0. If you use the Crime medical integration, start Ambulance 2.46.0 before Crime 0.10.0. Mechanic 1.36.0 and Fire 1.18.0 follow both libraries. Include only resources you have installed.

</template>

<template v-slot:files="">

Use the complete `1.18.0` customer package. Delete the entire `sky_firejob/source/` folder and insert the new one. Replace `sky_firejob/fxmanifest.lua` from the same download; do not merge old generated interface or bootstrap files. Refresh the complete `sky_firejob/config/locales/` tree and merge custom translations without restoring an older dictionary. Preserve the selected `locale` value in `sky_base/config/config.lua`.

Install the new `sky_firejob/meta/eu_hose_clip_sets.meta` and replace `sky_firejob/meta/weaponanimations.meta`. Add `sky_firejob/stream/sky_fire_hose_eu.ycd` and replace `sky_firejob/stream/w_am_hohlstrahlrohr.ydr`. These two meta files, animation, nozzle model, manifest and complete source must come from the same 1.18.0 package. Preserve unrelated custom models and do not copy development Blender/storage files. Install the matching Jobs Base 1.50.0 locale packs as part of the Jobs Base update.

</template>

<template v-slot:config="">

No Fire configuration option, shipped default or `/jobconfig` key is added, removed or renamed from 1.17.0. Preserve `config/config.lua`, your hose vehicle setup, response/reward settings and custom integrations. The supplied `Config.Hose.nozzleModel = "normal"` is unchanged; the EU grip is used by the existing `"hohlstrahlrohr"` selection. Keep your chosen nozzle; installing the assets does not change the selection.

With `Config.UseJobConfigurator = true`, active managed values remain shipped defaults plus your saved `/jobconfig` overrides. Do not reset jobs, grades, locations, permissions or feature settings, and do not import plaintext as a routine update step. With the configurator disabled, your existing plaintext values remain active. The Scenario Hub error improvement requires no new key, secret or endpoint setting.

Refresh the complete gameplay locale tree and merge only your own text changes. FireRadial and OilSpills `icon`/`*Icon` values are technical icon identifiers such as `Waves`, `Plug`, `Unplug` and `Brush`; retain their exact supplied spelling in every language.

Optional profiling is disabled by default. If support requests a recording, put `setr sky_profiler 1` in `server.cfg` before the Sky `ensure` lines and perform a full server restart. In the server console, run `profiler record 1000`, wait for `profiler status` to show completion, then run `profiler saveJSON sky-release-20261014.json`; choose a new filename for each recording. Disable it with `setr sky_profiler 0` and another full server restart. This is not a `/jobconfig` setting. No recording or upload starts automatically.

</template>

<template v-slot:data="">

**Database:** No new Fire table, column or manual SQL migration is introduced from 1.17.0. Preserve incidents, reports and saved settings.

**Items and permissions:** No new inventory definition, image registration or permission is required.

**Streamed assets:** Add `sky_firejob/stream/sky_fire_hose_eu.ycd` and replace `sky_firejob/stream/w_am_hohlstrahlrohr.ydr`. Install `sky_firejob/meta/eu_hose_clip_sets.meta`, `sky_firejob/meta/weaponanimations.meta` and the matching manifest together; the manifest registers the new animation clip set. Installing only the nozzle model is incomplete. No non-source removal or rename is needed.

</template>

<template v-slot:verify="">

Perform a full server restart after all replacements and migrations so manifests and file lists reload, then reconnect clients. Start the framework, database connector and selected inventory, phone, banking and UI providers first, then sky_base 1.47.0 and sky_jobs_base 1.50.0, followed by the installed job resources. If you use DOJ with Police, start DOJ 0.5.0 before Police 1.39.0. If you use the Crime medical integration, start Ambulance 2.46.0 before Crime 0.10.0. Mechanic 1.36.0 and Fire 1.18.0 follow both libraries. Include only resources you have installed. Check the actual installed versions and the first startup/database error before testing.

Reconnect after the full restart. If the older nozzle animation remains cached, disconnect and reconnect before comparing the grip. On a staging setup using `hohlstrahlrohr`, check idle, walking, aiming and spraying, including the hose route below the right arm. Keep the normal nozzle selection unchanged if that is your chosen setup. Open fire-service radial actions in your chosen language and verify their icons. Open Reports, File Explorer and nearby-player invoicing. If the Scenario Hub cannot connect, inspect its first failure log; keep signing secrets and credentials private.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-10-09" title="Version 1.17.0">
<template v-slot:body="">

**Highlights**

- Improved File Explorer loading so ordinary folders remain available while shared document data loads.

**Notable Changes**

- Improved shared document and video previews, with clearer feedback when a document cannot be loaded.
- Improved court execution forms with automatic deadline updates that preserve entered details.
- Improved minigame closing to stop inactive animation, audio and timers.
- Fixed simple and enhanced pump panel scaling so gauges, labels and controls resize together with screen height and fit narrow viewports.
- Fixed the vehicle water-transfer action remaining hidden in the normal radial menu at a valid vehicle connection.

**Other Changes**

- Improved targeted invoices so the selected recipient stays attached to the invoice throughout creation.

**Changed Files**

- `sky_firejob/config/locales/*`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/source/*` — delete and reinsert

<update-guide from="1.16.1" resource="sky_firejob" to="1.17.0">
<template v-slot:simplified="">

1. **Prepare**

These instructions cover `sky_firejob` `1.16.1` → `1.17.0`. Complete applicable earlier migrations when upgrading from an older version. Back up the database, resources, framework files, custom configuration/translations and saved `/jobconfig`/Creator data. Test on staging and stop the server for replacement. Install the coordinated versions for your installed resources. Start the framework, database connector and selected inventory, phone, banking and UI providers first, then Base `1.46.0` and Jobs Base `1.49.0`. Start DOJ `0.4.0` before Police `1.38.0` for their shared catalogue and court workflows. Start Ambulance `2.45.0` before Crime `0.9.0` when using their medical integration. Mechanic `1.35.0` and Fire `1.17.0` follow both libraries. Include only installed resources.

1. **Replace files**

Use the complete `1.17.0` customer package. Delete the entire `sky_firejob/source/` folder and insert the new one, then replace `sky_firejob/fxmanifest.lua` from the same package. Refresh the complete `sky_firejob/config/locales/` tree and merge custom translations. Preserve your selected language. Do not restore an older bootstrap or merge generated interface files.

Refresh the complete locale tree and replace the generated source and matching manifest. No executable Fire config file change needs merging for this release.

Install Jobs Base `1.49.0` together with Fire `1.17.0`: the restored water-transfer action requires the matching radial target handling. Replace both complete source folders and manifests before the restart.

1. **Merge settings**

When `Config.UseJobConfigurator = true`, saved `/jobconfig` settings take precedence over the plaintext defaults. Change the effective values in `/jobconfig`; copying config files does not replace saved jobs, grades, locations or overrides. Keep the saved data and do not reset the configurator. Use `/jobconfigimport sky_firejob` only if you intentionally want to import your edited plaintext configuration, after backing up and reviewing its replacement scope. With `Config.UseJobConfigurator = false`, merge the settings into the supplied config files instead.

No new Fire setting, renamed key or shipped default. Retain selected language, saved jobs, grades, locations, permissions and feature switches. If using court document integration, update the installed DOJ resource to `0.4.0` and Jobs Base to `1.49.0`. New linked-job actions remain opt-in in Jobs Base; Fire behaviour is not enabled by copying defaults.

The radial water-transfer fix introduces no new configuration key or changed default. Keep your existing vehicle-transfer settings and saved overrides.

Optional profiling remains off by default. If support requests it, put `setr sky_profiler 1` before the Sky `ensure` lines in `server.cfg`, perform a full server restart, run `profiler record 1000`, wait for `profiler status` to show completion, then run `profiler saveJSON sky-release-20261008.json` with a new filename for each capture. Disable it with `setr sky_profiler 0` and another full server restart. This is not a `/jobconfig` setting; no recording or upload starts automatically.

1. **Database, items and assets**

SQL: No new Fire table, column or manual migration. Existing records and saved settings remain. Items: No new definitions. Assets: No new inventory images, maps or streamed models.

1. **Restart and check**

Perform a full server restart to reload changed manifests and file lists, then reconnect clients. Start the framework, database connector and selected inventory, phone, banking and UI providers first, then Base `1.46.0` and Jobs Base `1.49.0`. Start DOJ `0.4.0` before Police `1.38.0` for their shared catalogue and court workflows. Start Ambulance `2.45.0` before Crime `0.9.0` when using their medical integration. Mechanic `1.35.0` and Fire `1.17.0` follow both libraries. Include only installed resources. Check actual installed versions and the first startup/database error before testing.

Confirm normal Fire job access, folders, shared document/video previews and an invoice for a selected recipient. With DOJ installed, open a court execution form and confirm deadline updates preserve entered details. Open and close a minigame and check that audio and controls finish with the view. Retain your existing permission and duty rules. Open both pump panel variants at your supported resolutions, check gauges and all controls fit, change pressure and connection counts, toggle the pump and close with Escape.

With vehicle water transfer enabled, aim the normal radial at a valid vehicle connection, pull the transfer line, connect it to the other vehicle and check cancellation. Confirm the existing port interaction remains available without a duplicate global vehicle-target option.

</template>

<template v-slot:prepare="">

These instructions cover `sky_firejob` `1.16.1` → `1.17.0`. Complete applicable earlier migrations when upgrading from an older version. Back up the database, resources, framework files, custom configuration/translations and saved `/jobconfig`/Creator data. Test on staging and stop the server for replacement. Install the coordinated versions for your installed resources. Start the framework, database connector and selected inventory, phone, banking and UI providers first, then Base `1.46.0` and Jobs Base `1.49.0`. Start DOJ `0.4.0` before Police `1.38.0` for their shared catalogue and court workflows. Start Ambulance `2.45.0` before Crime `0.9.0` when using their medical integration. Mechanic `1.35.0` and Fire `1.17.0` follow both libraries. Include only installed resources.

</template>

<template v-slot:files="">

Use the complete `1.17.0` customer package. Delete the entire `sky_firejob/source/` folder and insert the new one, then replace `sky_firejob/fxmanifest.lua` from the same package. Refresh the complete `sky_firejob/config/locales/` tree and merge custom translations. Preserve your selected language. Do not restore an older bootstrap or merge generated interface files.

Refresh the complete locale tree and replace the generated source and matching manifest. No executable Fire config file change needs merging for this release.

Install Jobs Base `1.49.0` together with Fire `1.17.0`: the restored water-transfer action requires the matching radial target handling. Replace both complete source folders and manifests before the restart.

</template>

<template v-slot:config="">

When `Config.UseJobConfigurator = true`, saved `/jobconfig` settings take precedence over the plaintext defaults. Change the effective values in `/jobconfig`; copying config files does not replace saved jobs, grades, locations or overrides. Keep the saved data and do not reset the configurator. Use `/jobconfigimport sky_firejob` only if you intentionally want to import your edited plaintext configuration, after backing up and reviewing its replacement scope. With `Config.UseJobConfigurator = false`, merge the settings into the supplied config files instead.

No new Fire setting, renamed key or shipped default. Retain selected language, saved jobs, grades, locations, permissions and feature switches. If using court document integration, update the installed DOJ resource to `0.4.0` and Jobs Base to `1.49.0`. New linked-job actions remain opt-in in Jobs Base; Fire behaviour is not enabled by copying defaults.

The radial water-transfer fix introduces no new configuration key or changed default. Keep your existing vehicle-transfer settings and saved overrides.

Optional profiling remains off by default. If support requests it, put `setr sky_profiler 1` before the Sky `ensure` lines in `server.cfg`, perform a full server restart, run `profiler record 1000`, wait for `profiler status` to show completion, then run `profiler saveJSON sky-release-20261008.json` with a new filename for each capture. Disable it with `setr sky_profiler 0` and another full server restart. This is not a `/jobconfig` setting; no recording or upload starts automatically.

</template>

<template v-slot:data="">

SQL: No new Fire table, column or manual migration. Existing records and saved settings remain. Items: No new definitions. Assets: No new inventory images, maps or streamed models.

</template>

<template v-slot:verify="">

Perform a full server restart to reload changed manifests and file lists, then reconnect clients. Start the framework, database connector and selected inventory, phone, banking and UI providers first, then Base `1.46.0` and Jobs Base `1.49.0`. Start DOJ `0.4.0` before Police `1.38.0` for their shared catalogue and court workflows. Start Ambulance `2.45.0` before Crime `0.9.0` when using their medical integration. Mechanic `1.35.0` and Fire `1.17.0` follow both libraries. Include only installed resources. Check actual installed versions and the first startup/database error before testing.

Confirm normal Fire job access, folders, shared document/video previews and an invoice for a selected recipient. With DOJ installed, open a court execution form and confirm deadline updates preserve entered details. Open and close a minigame and check that audio and controls finish with the view. Retain your existing permission and duty rules. Open both pump panel variants at your supported resolutions, check gauges and all controls fit, change pressure and connection counts, toggle the pump and close with Escape.

With vehicle water transfer enabled, aim the normal radial at a valid vehicle connection, pull the transfer line, connect it to the other vehicle and check cancellation. Confirm the existing port interaction remains available without a duplicate global vehicle-target option.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-10-06" title="Version 1.16.1">
<template v-slot:body="">

**Highlights**

- Fixed an issue where Fire failed to initialize when shared dependencies took more than 60 seconds to load.

**Notable Changes**

- Improved Fire startup so a failed migration is reported without aborting the entire initializer.

**Other Changes**

- Updated the release package to keep its own dependency bootstrap editable for support.

**Changed Files**

- `sky_firejob/config/locales/*`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/source/*` — delete and reinsert

<update-guide from="1.16.0" resource="sky_firejob" to="1.16.1">
<template v-slot:simplified="">

1. **Prepare**

These instructions cover `sky_firejob` `1.16.0` → the refreshed `1.16.1` package. If you installed an earlier `1.16.1` download today, download the current `1.16.1` package again and apply these steps. The manifest version stays the same, so the version number alone does not identify the refreshed package. Back up resources, the database, custom configuration, translations and saved Job Configurator/Creator data. Validate on staging and stop the server for replacement. Install the refreshed Base `1.45.1`, then Jobs Base `1.48.1`, then the matching updates for your installed jobs and Crime. Complete earlier migrations first when upgrading from an older version.

1. **Replace files**

Use the complete `1.16.1` package. Delete the entire `sky_firejob/source/` folder and insert its new version, then replace `sky_firejob/fxmanifest.lua` from the same package. Do not merge old generated interface files. Refresh the complete `sky_firejob/config/locales/` tree and merge custom translations. Keep your existing selected language in `sky_base/config/config.lua`.

The dependency bootstrap ships as an editable file. Use the supplied file; do not restore an older custom bootstrap. Base also keeps its callback files editable for support. Install the source and manifest together.

1. **Merge settings**

No plaintext configuration options, Job Configurator keys or defaults are added, removed or reset by this hotfix. Keep your existing configuration, jobs, grades, locations and saved overrides. `/jobconfig` does not replace runtime files, install schema or reload changed manifests. No configuration import or reset is required.

Optional diagnostics are disabled by default. If support requests a recording, put `setr sky_profiler 1` before the Sky `ensure` lines in `server.cfg`, restart the server, run `profiler record 1000`, wait for `profiler status` to show completion, then run `profiler saveJSON sky-startup-hotfix.json`. Disable with `setr sky_profiler 0` and another full server restart. This is not a `/jobconfig` setting; no recording or upload starts automatically.

1. **Database, items and assets**

SQL: No new table, column or manual SQL update is introduced by this patch. Existing failed migrations still need their original database error repaired; continuing startup does not create a missing schema. Keep the existing automatic/manual migration policy. Do not replay a full import, clear tables, force success markers or reset saved job/Creator data. Items: No new definitions or inventory registrations. Assets: No new item images, models or stream assets; keep existing assets. Earlier release requirements still apply for older installations.

1. **Restart and check**

Perform a full server restart after replacement so the changed manifests and file lists are reloaded. Start the framework, database connector and selected providers first, then Base `1.45.1`, Jobs Base `1.48.1` and the installed consumers. Unrelated clothing, vehicle and map packs can remain after Sky in `server.cfg`. Reconnect clients. Open the Fire tablet and check your configured locations and normal duty workflow. A long dependency wait now continues until initialization completes; it no longer aborts at 60 seconds. Database migration warnings remain actionable, and failure to read saved settings remains a visible initialization error. Collect the first error, preceding lines and actual installed versions if a feature remains unavailable.

</template>

<template v-slot:prepare="">

These instructions cover `sky_firejob` `1.16.0` → the refreshed `1.16.1` package. If you installed an earlier `1.16.1` download today, download the current `1.16.1` package again and apply these steps. The manifest version stays the same, so the version number alone does not identify the refreshed package. Back up resources, the database, custom configuration, translations and saved Job Configurator/Creator data. Validate on staging and stop the server for replacement. Install the refreshed Base `1.45.1`, then Jobs Base `1.48.1`, then the matching updates for your installed jobs and Crime. Complete earlier migrations first when upgrading from an older version.

</template>

<template v-slot:files="">

Use the complete `1.16.1` package. Delete the entire `sky_firejob/source/` folder and insert its new version, then replace `sky_firejob/fxmanifest.lua` from the same package. Do not merge old generated interface files. Refresh the complete `sky_firejob/config/locales/` tree and merge custom translations. Keep your existing selected language in `sky_base/config/config.lua`.

The dependency bootstrap ships as an editable file. Use the supplied file; do not restore an older custom bootstrap. Base also keeps its callback files editable for support. Install the source and manifest together.

</template>

<template v-slot:config="">

No plaintext configuration options, Job Configurator keys or defaults are added, removed or reset by this hotfix. Keep your existing configuration, jobs, grades, locations and saved overrides. `/jobconfig` does not replace runtime files, install schema or reload changed manifests. No configuration import or reset is required.

Optional diagnostics are disabled by default. If support requests a recording, put `setr sky_profiler 1` before the Sky `ensure` lines in `server.cfg`, restart the server, run `profiler record 1000`, wait for `profiler status` to show completion, then run `profiler saveJSON sky-startup-hotfix.json`. Disable with `setr sky_profiler 0` and another full server restart. This is not a `/jobconfig` setting; no recording or upload starts automatically.

</template>

<template v-slot:data="">

SQL: No new table, column or manual SQL update is introduced by this patch. Existing failed migrations still need their original database error repaired; continuing startup does not create a missing schema. Keep the existing automatic/manual migration policy. Do not replay a full import, clear tables, force success markers or reset saved job/Creator data. Items: No new definitions or inventory registrations. Assets: No new item images, models or stream assets; keep existing assets. Earlier release requirements still apply for older installations.

</template>

<template v-slot:verify="">

Perform a full server restart after replacement so the changed manifests and file lists are reloaded. Start the framework, database connector and selected providers first, then Base `1.45.1`, Jobs Base `1.48.1` and the installed consumers. Unrelated clothing, vehicle and map packs can remain after Sky in `server.cfg`. Reconnect clients. Open the Fire tablet and check your configured locations and normal duty workflow. A long dependency wait now continues until initialization completes; it no longer aborts at 60 seconds. Database migration warnings remain actionable, and failure to read saved settings remains a visible initialization error. Collect the first error, preceding lines and actual installed versions if a feature remains unavailable.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-10-06" title="Version 1.16.0">
<template v-slot:body="">

**Highlights**

- Added an optional three-way hose divider with inventory placement, separate branch valves, supply connections and a nearby setup checklist.
- Added a selectable EU hose nozzle alongside the existing normal nozzle, with model previews in the Job Configurator.
- Added central invoice management to the Fire Explorer, including payment progress and eligible installment plans.

**Notable Changes**

- Fixed an issue where moving vehicle fires could stop responding to hose hits at their current position.
- Changed the default vehicle-fuel settings so hose water can extinguish those fires without triggering a worsening water reaction.
- Changed the default Fire billing mode to use the provider selected in Sky Base, while retaining the existing local cash/card payment mode.
- Added gang selectors to the existing access lists for fire equipment, extinguisher work and oil cleanup.
- Improved the mission asset picker with a shared catalogue, category filters and custom model entry.
- Fixed an issue where failed Mission Hub loads appeared as an empty list by showing the error, a retry action and fresh results when reopened.
- Fixed an issue where reloading the interface during mission editing could leave the editor camera and player controls active.

**Other Changes**

- Improved the trapped-player vehicle display with clearer vehicle artwork, door positions and readable door-status labels.
- Improved invoice receipts and printer controls so longer documents remain readable within the device screen.
- Added shared price-catalogue choices and preserved invoice retry references after failed replies.
- Improved shared-document browsing by grouping authorized documents by type and their associated citizen or vehicle.
- Improved tablet form fields with content-sized descriptions and clearer select actions.
- Fixed an issue where startup requests could arrive before Fire menus, settings and tablet callbacks were ready.
- Fixed an issue where saved divider settings or an interface reload could leave divider interactions and the checklist out of sync.
- Fixed an issue where divider branch hoses used the truck's position instead of the divider's position when placed on the ground.
- Fixed an issue where incomplete divider positions or branch values could be accepted.
- Fixed an issue where the new nozzle weapon metadata could fail to load because its text encoding declaration was invalid.

**Changed Files**

- `sky_firejob/config/config.lua`
- `sky_firejob/config/init.lua`
- `sky_firejob/config/inventory/fire_dividing_breeching.png`
- `sky_firejob/config/locales/*`
- `sky_firejob/config/sv_functions.lua`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/meta/pedpersonality.meta`
- `sky_firejob/meta/weaponanimations.meta`
- `sky_firejob/meta/weaponarchetypes.meta`
- `sky_firejob/meta/weapons.meta`
- `sky_firejob/source/*` — delete and reinsert
- `sky_firejob/stream/dividing_breeching/sky_dividing_breeching.ydr`
- `sky_firejob/stream/dividing_breeching/sky_dividing_breeching.ytyp`
- `sky_firejob/stream/dividing_breeching/sky_dividing_tap_1.ydr`
- `sky_firejob/stream/dividing_breeching/sky_dividing_tap_2.ydr`
- `sky_firejob/stream/dividing_breeching/sky_dividing_tap_3.ydr`
- `sky_firejob/stream/w_am_hohlstrahlrohr.ydr`

<update-guide from="1.15.1" resource="sky_firejob" to="1.16.0">
<template v-slot:simplified="">

1. **Prepare**

These instructions cover `sky_firejob` `1.15.1` → `1.16.0`. Before replacing files, confirm that your customer download platform provides the versions below and check each downloaded resource's `fxmanifest.lua`; published documentation or a source tag alone does not establish that its customer download has been uploaded. Complete earlier migrations first if upgrading from an older version. Back up the database, resources, custom config, translations and saved Job Configurator/Creator data. Validate the update on staging before applying it to your production server. Stop the server during replacement. Install Sky Base `1.45.0`, then Sky Jobs Base `1.48.0`, then the matching releases for your installed jobs and Crime. Keep provider dependencies and optional integrations compatible; preserve saved overrides and existing records.

1. **Replace files**

Use the complete `1.16.0` release package. Delete the entire `sky_firejob/source/` folder and insert its new version; do not merge old generated interface files. Replace `sky_firejob/fxmanifest.lua` from the same package. Refresh the complete `sky_firejob/config/locales/` tree and merge your custom translations into the new files. Keep your selected shared language in `sky_base/config/config.lua`. Install the following shipped paths from that package, merging custom configuration into the updated public files rather than restoring old complete files:

- `sky_firejob/config/config.lua`
- `sky_firejob/config/init.lua`
- `sky_firejob/config/inventory/fire_dividing_breeching.png`
- `sky_firejob/config/locales/*`
- `sky_firejob/config/sv_functions.lua`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/meta/pedpersonality.meta`
- `sky_firejob/meta/weaponanimations.meta`
- `sky_firejob/meta/weaponarchetypes.meta`
- `sky_firejob/meta/weapons.meta`
- `sky_firejob/source/*` — delete and reinsert
- `sky_firejob/stream/dividing_breeching/sky_dividing_breeching.ydr`
- `sky_firejob/stream/dividing_breeching/sky_dividing_breeching.ytyp`
- `sky_firejob/stream/dividing_breeching/sky_dividing_tap_1.ydr`
- `sky_firejob/stream/dividing_breeching/sky_dividing_tap_2.ydr`
- `sky_firejob/stream/dividing_breeching/sky_dividing_tap_3.ydr`
- `sky_firejob/stream/w_am_hohlstrahlrohr.ydr`

1. **Merge configuration**

In sky_firejob/config/config.lua, preserve your existing vehicle placements, job lists, incident settings and rewards. No old configuration block or option is removed in this release.

If you manage settings through /jobconfig, select Firejob and review Billing, Hose, Vehicle Fires, Oil Cleanup, Interior Extinguishers, Water Monitor, Water Bucket and Rescue Cushion. Existing saved settings remain effective; replacing config.lua does not overwrite them. Save the values you want there. For installations without /jobconfig, merge the following exact changes into config.lua.

**Billing.** The shipped Config.Billing.mode changes from "consent" to "framework". "framework" uses the provider selected by Config.billing in sky_base/config/config.lua; with "sky", invoices use Sky Billing. "consent" remains available for the existing local cash/card prompt. Keep your enabled/range/maxAmount/reasons values. The old default block was:

```lua
Config.Billing = {
    enabled = true,
    mode = "consent",
    range = 6.0,
    maxAmount = 50000,
    reasons = {}
}
```

The new complete default block is:

```lua
Config.Billing = {
    enabled = true,
    mode = "framework",
    range = 6.0,
    maxAmount = 50000,
    reasons = {}
}
```

In /jobconfig → Firejob → Billing, the equivalent setting is fireBillingMode; choose "framework" to adopt the provider flow or keep "consent" intentionally. The other existing settings are fireBillingEnabled, fireBillingRange, fireBillingMaxAmount and fireBillingReasons. Invoices being issued are distinct from their being paid; only confirmed payment becomes society income.

**Hose.** Three settings were absent from the old Config.Hose table. Add these complete new entries inside that existing table; retain every other hose field:

```lua
nozzleModel = "normal", -- "normal" or "hohlstrahlrohr"
dividing = false,
hollowNozzleGroundOffset = 0.0,
```

The default nozzle remains the normal nozzle. Set nozzleModel = "hohlstrahlrohr" for the EU nozzle. Set dividing = true only when you want the three-way divider. hollowNozzleGroundOffset is the EU nozzle's vertical ground correction; the existing groundedNozzleOffset = -0.38 remains the normal nozzle correction. In /jobconfig → Firejob → Hose, use hoseNozzleModel under Nozzle, hoseDividing under General and hoseHollowNozzleGroundOffset under Nozzle → Ground Placement. The model selector offers Normal nozzle and EU nozzle; custom model names are not accepted. Changing the nozzle model returns deployed attack hoses, so switch it while equipment is not in use. Config.Hose.vehicles, its pump panel/intake/outlet geometry and all existing vehicle definitions have no net configuration change in this release; keep the model-specific coordinates you already configured.

**Vehicle fuel fires.** In Config.FireSystem.materials.vehicle_fuel, the old complete public override was:

```lua
vehicle_fuel = {
    allowedExtinguishAgents = { water = false, foam = true, water_monitor = false, extinguisher = true },
    waterEffectiveness = 0.0,
    foamEffectiveness = 1.35
}
```

Replace that override with this complete new public block:

```lua
vehicle_fuel = {
    allowedExtinguishAgents = { water = true, foam = true, water_monitor = false, extinguisher = true },
    waterEffectiveness = 0.65,
    foamEffectiveness = 1.35,
    waterReaction = { enabled = false }
}
```

The new waterReaction table is fully shown above; the previous public block had no such table and inherited an enabled water reaction. Only its enabled value changes; preserve any intentional custom reaction tuning. Water means the hose/nozzle, firetruck cannon and helicopter bucket. Portable Water Monitor water remains disabled for this material. The effective default changes are water false → true, waterEffectiveness 0.0 → 0.65, waterReaction.enabled true → false; foam, Water Monitor and extinguisher permissions remain unchanged. In /jobconfig → Firejob → Vehicle Fires, set vehicleFiresCanExtinguishWater = true, vehicleFiresWaterEffectiveness = 0.65 and vehicleFiresWaterReactionEnabled = false to adopt those defaults. Keep vehicleFiresCanExtinguishFoam = true, vehicleFiresCanExtinguishExtinguisher = true, vehicleFiresCanExtinguishWaterMonitor = false and vehicleFiresFoamEffectiveness = 1.35, unless you intentionally customized them. Existing reaction tuning keys vehicleFiresWaterReactionChance, vehicleFiresWaterReactionInterval, vehicleFiresWaterReactionExplosionChance, vehicleFiresWaterReactionSpreadCount and vehicleFiresWaterReactionSmokeIncrease retain their meaning. If you selected another material for Config.VehicleFires.material, these settings affect that selected material rather than automatically replacing it with vehicle_fuel.

**Optional gang access.** Existing exact job names and job groups remain valid. The following existing selector lists now also accept gang:<internal_name> where your configured gang integration supplies membership:

- Config.OilSpills.cleanup.allowedJobs ↔ oilCleanupAllowedJobs: additional access alongside all configured Firejob jobs. An empty list grants no additional selectors; it does not remove configured Firejob access.
- Config.InteriorExtinguishers.allowedJobs ↔ interiorExtinguishersAllowedJobs: an empty list allows every job, with requireOnDuty still enforced.
- Config.InteriorExtinguishers.noDutyJobs ↔ interiorExtinguishersNoDutyJobs: exempt selectors may take/restock extinguishers without job duty; an empty list provides no exemptions.
- Config.InteriorExtinguishers.maintenance.allowedJobs ↔ interiorExtinguishersMaintenanceAllowedJobs: additional access alongside configured Firejob jobs; an empty list adds nobody.
- Config.InteriorExtinguishers.placement.allowedJobs ↔ interiorExtinguishersPlacementAllowedJobs: an empty list allows every job, with placement.requireOnDuty still enforced.
- Config.WaterMonitor.allowedJobs ↔ waterMonitorAllowedJobs: an empty list uses configured Firejob jobs.
- Config.HeliBucket.allowedJobs ↔ heliBucketAllowedJobs: an empty list uses configured Firejob jobs.
- Config.RescueCushion.allowedJobs ↔ rescueCushionAllowedJobs: an empty list uses configured Firejob jobs.

Keep the corresponding requireOnDuty settings for job-based access. Gang membership is checked independently of job duty. No selector/default list migration is required; only add gang selectors if desired. This equipment access does not grant the new divider workflow to gangs: that workflow requires an on-duty configured Firejob job.

Replace sky_firejob/config/init.lua from the same download. If you customized sky_firejob/config/sv_functions.lua, retain your dispatch hook while merging its new leading readiness line:

```lua
if not Citizen.Await(SkyJobsReady) then return end
```

Do not copy an older init or hook file back over the updated dependency initialization.

Use the matching updated sky_jobs_base together with Firejob. The additional configuration update routing does not change Firejob setting keys, defaults, saved overrides, inventory setup or SQL requirements.

**Truck pump connections required by the divider.** The vehicle geometry fields in `Config.Hose.vehicles` retain their existing names and defaults. Configure each intended truck in `/jobconfig → Firejob → Pump Panel → Vehicles` (table `hoseVehicles`). In its row, use **Hose Control access** (`pumpPanelAccess`) to place the operating panel; this writes `pumpPanelConfigured`, `pumpPanelX`, `pumpPanelY`, `pumpPanelZ` and `pumpPanelSize`. Set `pumpIntakeCount` (up to 2) and place each enabled `pumpIntakeN*` connection; set `pumpDischargeCount` (up to 4) and place each enabled `pumpOutletN*` connection. Preserve your truck-specific coordinates. In plaintext mode merge these same panel/intake/outlet fields from the supplied vehicle definition and set their coordinates for that actual vehicle. Do not copy example coordinates from a different truck. A divider requires the configured supply connection and pump; installing the item alone does not configure a truck.

Optional diagnostics are disabled by default. If support requests a recording, put `setr sky_profiler 1` before the Sky `ensure` lines in `server.cfg`, then restart the server. Run `profiler record 1000`, wait for `profiler status` to show that recording has completed, then run `profiler saveJSON sky-release-profile.json`. Disable diagnostics with `setr sky_profiler 0` and another server restart. This is not a `/jobconfig` setting; no recording or upload starts automatically.

For an older explicit profiler package, replace any previously modified public config/provider/compatibility files with the supplied versions and merge your intentional customizations. In this release package, profiler preparation preserves all files outside `source/` byte for byte except `fxmanifest.lua`; the functional config changes listed in this guide still require their own merge.

1. **Data, items and dependencies**

**Database.** Firejob has no new database table, column or manual SQL migration in this release. Do not re-import or reset its existing database for the divider/nozzle update.

**Equipment assets.** Replace the four weapon metadata files sky_firejob/meta/pedpersonality.meta, weaponanimations.meta, weaponarchetypes.meta and weapons.meta together. Install sky_firejob/stream/w_am_hohlstrahlrohr.ydr and all five files in sky_firejob/stream/dividing_breeching/: sky_dividing_breeching.ydr, sky_dividing_breeching.ytyp, sky_dividing_tap_1.ydr, sky_dividing_tap_2.ydr and sky_dividing_tap_3.ydr. The EU nozzle now uses weapon name WEAPON_SKY_HOSE_EU and streamed model w_am_hohlstrahlrohr; the configuration choice stays "hohlstrahlrohr". Update any custom code that references the earlier development name WEAPON_SKY_HOHLSTRAHLROHR. Keep the original normal-nozzle model. Update the complete source folder and fxmanifest.lua from that same download even if you keep the normal nozzle and divider disabled.

**Divider placement and items.** Keep the divider disabled until your inventory has registered an item named fire_dividing_breeching. Copy sky_firejob/config/inventory/fire_dividing_breeching.png from the download to your inventory's item-image directory and associate it with that exact item name. Firejob supplies the icon but no provider-specific item-definition template; register the item using your inventory's normal item catalogue rather than replacing that catalogue or copying an unrelated Jobs Base item. Do not configure a second usable-item handler: Firejob registers its own through Sky Base. Once enabled, an on-duty configured Firejob member uses that item to place the divider; placement consumes one item and radial removal returns one. The former /dividing placement command is no longer available. At a configured operational fire vehicle, take its supply hose through the radial menu, connect it to the divider, take an attack hose from the same vehicle and connect an available branch. Operate the divider's valves and the supplying truck pump; the nearby checklist shows the remaining connection/valve steps. Close unused open outlets to avoid wasting water. Do not assume /jobconfig installs the inventory item, its icon or the streamed assets.

**Billing provider.** For Sky Billing, use the coordinated sky_base 1.45.0 and sky_jobs_base 1.48.0 updates and select Config.billing = "sky" in sky_base/config/config.lua. Explicit external providers stay supported through mode = "framework"; the local mode = "consent" remains available. The shared invoice catalogue and installment eligibility come from Jobs Base's Billing settings, not a new Firejob SQL table. Install/update Jobs Base's billing database using its own instructions before testing Fire invoices. Installments are only offered for eligible invoices; do not promise them for every provider or invoice.

**Locales and interface assets.** Replace sky_firejob/config/locales/* completely, preserving any custom wording separately, and install the NUI build in the same source-folder replacement. The global language continues to come from Sky Base's Config.locale. The new HUD artwork is included in the built interface; it is not an inventory-image install. This release does not newly add Hungarian as a language.

**Manual ox_inventory example for the optional divider.** If you enable `Config.Hose.dividing`, merge the following entry into `ox_inventory/data/items.lua`. This is an example, not a supplied installer or mandatory label/weight; choose those two values for your server. Keep `consume = 0`, omit a second client Use handler, and let Sky consume one divider only after placement succeeds and return it when it is removed. Copy `sky_firejob/config/inventory/fire_dividing_breeching.png` to `ox_inventory/web/images/fire_dividing_breeching.png`, then restart the inventory before the dependent Sky resources.

```lua
['fire_dividing_breeching'] = {
    label = 'Fire hose divider',
    weight = 1000, -- Example weight: choose your server value.
    stack = true,
    close = true,
    consume = 0,
},
```

For a different inventory, use its installed catalogue format and image path while retaining the same item ID and reusable Use behavior. The EU hose nozzle does not need an additional inventory weapon entry: the hose runtime equips the selected nozzle weapon.

1. **Restart and check**

Start your framework, database connector and configured providers first, then Base, Jobs Base and the updated job resources in dependency order. Reconnect clients. After a complete restart, check an on-duty Firejob character can open the tablet and mission editor without startup errors. Confirm the effective Billing and Vehicle Fires settings in /jobconfig if enabled; issue one test invoice and verify its confirmed payment appears in the correct society account. With the divider enabled, give one registered fire_dividing_breeching item to an on-duty Firejob character, place it by using the item, connect its supply and one attack hose, open the appropriate valves and test water flow; remove it through the radial menu afterward and confirm the inventory item is returned. Switch between normal and EU nozzles when hoses are not deployed and check the held/grounded nozzle model. Test a moving burning vehicle, a failed Mission Hub request with its retry action and an interface reload during mission editing. Existing job selectors should retain their previous access/duty behavior; test any optional gang selector with an actual member.

After deploying the matching Jobs Base and Firejob, save one Firejob setting, then one unrelated resource's setting. Confirm Fire equipment settings, item availability and Fire tablet access still follow the Firejob profile. Restart Firejob and recheck the saved value.

If a check fails, keep the update on staging and collect the installed resource versions, selected provider, effective saved setting and the first relevant startup or action error. A successful source test, build or copy does not establish live FiveM, provider or customer acceptance.

</template>

<template v-slot:prepare="">

These instructions cover `sky_firejob` `1.15.1` → `1.16.0`. Before replacing files, confirm that your customer download platform provides the versions below and check each downloaded resource's `fxmanifest.lua`; published documentation or a source tag alone does not establish that its customer download has been uploaded. Complete earlier migrations first if upgrading from an older version. Back up the database, resources, custom config, translations and saved Job Configurator/Creator data. Validate the update on staging before applying it to your production server. Stop the server during replacement. Install Sky Base `1.45.0`, then Sky Jobs Base `1.48.0`, then the matching releases for your installed jobs and Crime. Keep provider dependencies and optional integrations compatible; preserve saved overrides and existing records.

</template>

<template v-slot:files="">

Use the complete `1.16.0` release package. Delete the entire `sky_firejob/source/` folder and insert its new version; do not merge old generated interface files. Replace `sky_firejob/fxmanifest.lua` from the same package. Refresh the complete `sky_firejob/config/locales/` tree and merge your custom translations into the new files. Keep your selected shared language in `sky_base/config/config.lua`. Install the following shipped paths from that package, merging custom configuration into the updated public files rather than restoring old complete files:

- `sky_firejob/config/config.lua`
- `sky_firejob/config/init.lua`
- `sky_firejob/config/inventory/fire_dividing_breeching.png`
- `sky_firejob/config/locales/*`
- `sky_firejob/config/sv_functions.lua`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/meta/pedpersonality.meta`
- `sky_firejob/meta/weaponanimations.meta`
- `sky_firejob/meta/weaponarchetypes.meta`
- `sky_firejob/meta/weapons.meta`
- `sky_firejob/source/*` — delete and reinsert
- `sky_firejob/stream/dividing_breeching/sky_dividing_breeching.ydr`
- `sky_firejob/stream/dividing_breeching/sky_dividing_breeching.ytyp`
- `sky_firejob/stream/dividing_breeching/sky_dividing_tap_1.ydr`
- `sky_firejob/stream/dividing_breeching/sky_dividing_tap_2.ydr`
- `sky_firejob/stream/dividing_breeching/sky_dividing_tap_3.ydr`
- `sky_firejob/stream/w_am_hohlstrahlrohr.ydr`

</template>

<template v-slot:config="">

In sky_firejob/config/config.lua, preserve your existing vehicle placements, job lists, incident settings and rewards. No old configuration block or option is removed in this release.

If you manage settings through /jobconfig, select Firejob and review Billing, Hose, Vehicle Fires, Oil Cleanup, Interior Extinguishers, Water Monitor, Water Bucket and Rescue Cushion. Existing saved settings remain effective; replacing config.lua does not overwrite them. Save the values you want there. For installations without /jobconfig, merge the following exact changes into config.lua.

**Billing.** The shipped Config.Billing.mode changes from "consent" to "framework". "framework" uses the provider selected by Config.billing in sky_base/config/config.lua; with "sky", invoices use Sky Billing. "consent" remains available for the existing local cash/card prompt. Keep your enabled/range/maxAmount/reasons values. The old default block was:

```lua
Config.Billing = {
    enabled = true,
    mode = "consent",
    range = 6.0,
    maxAmount = 50000,
    reasons = {}
}
```

The new complete default block is:

```lua
Config.Billing = {
    enabled = true,
    mode = "framework",
    range = 6.0,
    maxAmount = 50000,
    reasons = {}
}
```

In /jobconfig → Firejob → Billing, the equivalent setting is fireBillingMode; choose "framework" to adopt the provider flow or keep "consent" intentionally. The other existing settings are fireBillingEnabled, fireBillingRange, fireBillingMaxAmount and fireBillingReasons. Invoices being issued are distinct from their being paid; only confirmed payment becomes society income.

**Hose.** Three settings were absent from the old Config.Hose table. Add these complete new entries inside that existing table; retain every other hose field:

```lua
nozzleModel = "normal", -- "normal" or "hohlstrahlrohr"
dividing = false,
hollowNozzleGroundOffset = 0.0,
```

The default nozzle remains the normal nozzle. Set nozzleModel = "hohlstrahlrohr" for the EU nozzle. Set dividing = true only when you want the three-way divider. hollowNozzleGroundOffset is the EU nozzle's vertical ground correction; the existing groundedNozzleOffset = -0.38 remains the normal nozzle correction. In /jobconfig → Firejob → Hose, use hoseNozzleModel under Nozzle, hoseDividing under General and hoseHollowNozzleGroundOffset under Nozzle → Ground Placement. The model selector offers Normal nozzle and EU nozzle; custom model names are not accepted. Changing the nozzle model returns deployed attack hoses, so switch it while equipment is not in use. Config.Hose.vehicles, its pump panel/intake/outlet geometry and all existing vehicle definitions have no net configuration change in this release; keep the model-specific coordinates you already configured.

**Vehicle fuel fires.** In Config.FireSystem.materials.vehicle_fuel, the old complete public override was:

```lua
vehicle_fuel = {
    allowedExtinguishAgents = { water = false, foam = true, water_monitor = false, extinguisher = true },
    waterEffectiveness = 0.0,
    foamEffectiveness = 1.35
}
```

Replace that override with this complete new public block:

```lua
vehicle_fuel = {
    allowedExtinguishAgents = { water = true, foam = true, water_monitor = false, extinguisher = true },
    waterEffectiveness = 0.65,
    foamEffectiveness = 1.35,
    waterReaction = { enabled = false }
}
```

The new waterReaction table is fully shown above; the previous public block had no such table and inherited an enabled water reaction. Only its enabled value changes; preserve any intentional custom reaction tuning. Water means the hose/nozzle, firetruck cannon and helicopter bucket. Portable Water Monitor water remains disabled for this material. The effective default changes are water false → true, waterEffectiveness 0.0 → 0.65, waterReaction.enabled true → false; foam, Water Monitor and extinguisher permissions remain unchanged. In /jobconfig → Firejob → Vehicle Fires, set vehicleFiresCanExtinguishWater = true, vehicleFiresWaterEffectiveness = 0.65 and vehicleFiresWaterReactionEnabled = false to adopt those defaults. Keep vehicleFiresCanExtinguishFoam = true, vehicleFiresCanExtinguishExtinguisher = true, vehicleFiresCanExtinguishWaterMonitor = false and vehicleFiresFoamEffectiveness = 1.35, unless you intentionally customized them. Existing reaction tuning keys vehicleFiresWaterReactionChance, vehicleFiresWaterReactionInterval, vehicleFiresWaterReactionExplosionChance, vehicleFiresWaterReactionSpreadCount and vehicleFiresWaterReactionSmokeIncrease retain their meaning. If you selected another material for Config.VehicleFires.material, these settings affect that selected material rather than automatically replacing it with vehicle_fuel.

**Optional gang access.** Existing exact job names and job groups remain valid. The following existing selector lists now also accept gang:<internal_name> where your configured gang integration supplies membership:

- Config.OilSpills.cleanup.allowedJobs ↔ oilCleanupAllowedJobs: additional access alongside all configured Firejob jobs. An empty list grants no additional selectors; it does not remove configured Firejob access.
- Config.InteriorExtinguishers.allowedJobs ↔ interiorExtinguishersAllowedJobs: an empty list allows every job, with requireOnDuty still enforced.
- Config.InteriorExtinguishers.noDutyJobs ↔ interiorExtinguishersNoDutyJobs: exempt selectors may take/restock extinguishers without job duty; an empty list provides no exemptions.
- Config.InteriorExtinguishers.maintenance.allowedJobs ↔ interiorExtinguishersMaintenanceAllowedJobs: additional access alongside configured Firejob jobs; an empty list adds nobody.
- Config.InteriorExtinguishers.placement.allowedJobs ↔ interiorExtinguishersPlacementAllowedJobs: an empty list allows every job, with placement.requireOnDuty still enforced.
- Config.WaterMonitor.allowedJobs ↔ waterMonitorAllowedJobs: an empty list uses configured Firejob jobs.
- Config.HeliBucket.allowedJobs ↔ heliBucketAllowedJobs: an empty list uses configured Firejob jobs.
- Config.RescueCushion.allowedJobs ↔ rescueCushionAllowedJobs: an empty list uses configured Firejob jobs.

Keep the corresponding requireOnDuty settings for job-based access. Gang membership is checked independently of job duty. No selector/default list migration is required; only add gang selectors if desired. This equipment access does not grant the new divider workflow to gangs: that workflow requires an on-duty configured Firejob job.

Replace sky_firejob/config/init.lua from the same download. If you customized sky_firejob/config/sv_functions.lua, retain your dispatch hook while merging its new leading readiness line:

```lua
if not Citizen.Await(SkyJobsReady) then return end
```

Do not copy an older init or hook file back over the updated dependency initialization.

Use the matching updated sky_jobs_base together with Firejob. The additional configuration update routing does not change Firejob setting keys, defaults, saved overrides, inventory setup or SQL requirements.

**Truck pump connections required by the divider.** The vehicle geometry fields in `Config.Hose.vehicles` retain their existing names and defaults. Configure each intended truck in `/jobconfig → Firejob → Pump Panel → Vehicles` (table `hoseVehicles`). In its row, use **Hose Control access** (`pumpPanelAccess`) to place the operating panel; this writes `pumpPanelConfigured`, `pumpPanelX`, `pumpPanelY`, `pumpPanelZ` and `pumpPanelSize`. Set `pumpIntakeCount` (up to 2) and place each enabled `pumpIntakeN*` connection; set `pumpDischargeCount` (up to 4) and place each enabled `pumpOutletN*` connection. Preserve your truck-specific coordinates. In plaintext mode merge these same panel/intake/outlet fields from the supplied vehicle definition and set their coordinates for that actual vehicle. Do not copy example coordinates from a different truck. A divider requires the configured supply connection and pump; installing the item alone does not configure a truck.

Optional diagnostics are disabled by default. If support requests a recording, put `setr sky_profiler 1` before the Sky `ensure` lines in `server.cfg`, then restart the server. Run `profiler record 1000`, wait for `profiler status` to show that recording has completed, then run `profiler saveJSON sky-release-profile.json`. Disable diagnostics with `setr sky_profiler 0` and another server restart. This is not a `/jobconfig` setting; no recording or upload starts automatically.

For an older explicit profiler package, replace any previously modified public config/provider/compatibility files with the supplied versions and merge your intentional customizations. In this release package, profiler preparation preserves all files outside `source/` byte for byte except `fxmanifest.lua`; the functional config changes listed in this guide still require their own merge.

</template>

<template v-slot:data="">

**Database.** Firejob has no new database table, column or manual SQL migration in this release. Do not re-import or reset its existing database for the divider/nozzle update.

**Equipment assets.** Replace the four weapon metadata files sky_firejob/meta/pedpersonality.meta, weaponanimations.meta, weaponarchetypes.meta and weapons.meta together. Install sky_firejob/stream/w_am_hohlstrahlrohr.ydr and all five files in sky_firejob/stream/dividing_breeching/: sky_dividing_breeching.ydr, sky_dividing_breeching.ytyp, sky_dividing_tap_1.ydr, sky_dividing_tap_2.ydr and sky_dividing_tap_3.ydr. The EU nozzle now uses weapon name WEAPON_SKY_HOSE_EU and streamed model w_am_hohlstrahlrohr; the configuration choice stays "hohlstrahlrohr". Update any custom code that references the earlier development name WEAPON_SKY_HOHLSTRAHLROHR. Keep the original normal-nozzle model. Update the complete source folder and fxmanifest.lua from that same download even if you keep the normal nozzle and divider disabled.

**Divider placement and items.** Keep the divider disabled until your inventory has registered an item named fire_dividing_breeching. Copy sky_firejob/config/inventory/fire_dividing_breeching.png from the download to your inventory's item-image directory and associate it with that exact item name. Firejob supplies the icon but no provider-specific item-definition template; register the item using your inventory's normal item catalogue rather than replacing that catalogue or copying an unrelated Jobs Base item. Do not configure a second usable-item handler: Firejob registers its own through Sky Base. Once enabled, an on-duty configured Firejob member uses that item to place the divider; placement consumes one item and radial removal returns one. The former /dividing placement command is no longer available. At a configured operational fire vehicle, take its supply hose through the radial menu, connect it to the divider, take an attack hose from the same vehicle and connect an available branch. Operate the divider's valves and the supplying truck pump; the nearby checklist shows the remaining connection/valve steps. Close unused open outlets to avoid wasting water. Do not assume /jobconfig installs the inventory item, its icon or the streamed assets.

**Billing provider.** For Sky Billing, use the coordinated sky_base 1.45.0 and sky_jobs_base 1.48.0 updates and select Config.billing = "sky" in sky_base/config/config.lua. Explicit external providers stay supported through mode = "framework"; the local mode = "consent" remains available. The shared invoice catalogue and installment eligibility come from Jobs Base's Billing settings, not a new Firejob SQL table. Install/update Jobs Base's billing database using its own instructions before testing Fire invoices. Installments are only offered for eligible invoices; do not promise them for every provider or invoice.

**Locales and interface assets.** Replace sky_firejob/config/locales/* completely, preserving any custom wording separately, and install the NUI build in the same source-folder replacement. The global language continues to come from Sky Base's Config.locale. The new HUD artwork is included in the built interface; it is not an inventory-image install. This release does not newly add Hungarian as a language.

**Manual ox_inventory example for the optional divider.** If you enable `Config.Hose.dividing`, merge the following entry into `ox_inventory/data/items.lua`. This is an example, not a supplied installer or mandatory label/weight; choose those two values for your server. Keep `consume = 0`, omit a second client Use handler, and let Sky consume one divider only after placement succeeds and return it when it is removed. Copy `sky_firejob/config/inventory/fire_dividing_breeching.png` to `ox_inventory/web/images/fire_dividing_breeching.png`, then restart the inventory before the dependent Sky resources.

```lua
['fire_dividing_breeching'] = {
    label = 'Fire hose divider',
    weight = 1000, -- Example weight: choose your server value.
    stack = true,
    close = true,
    consume = 0,
},
```

For a different inventory, use its installed catalogue format and image path while retaining the same item ID and reusable Use behavior. The EU hose nozzle does not need an additional inventory weapon entry: the hose runtime equips the selected nozzle weapon.

</template>

<template v-slot:verify="">

Start your framework, database connector and configured providers first, then Base, Jobs Base and the updated job resources in dependency order. Reconnect clients. After a complete restart, check an on-duty Firejob character can open the tablet and mission editor without startup errors. Confirm the effective Billing and Vehicle Fires settings in /jobconfig if enabled; issue one test invoice and verify its confirmed payment appears in the correct society account. With the divider enabled, give one registered fire_dividing_breeching item to an on-duty Firejob character, place it by using the item, connect its supply and one attack hose, open the appropriate valves and test water flow; remove it through the radial menu afterward and confirm the inventory item is returned. Switch between normal and EU nozzles when hoses are not deployed and check the held/grounded nozzle model. Test a moving burning vehicle, a failed Mission Hub request with its retry action and an interface reload during mission editing. Existing job selectors should retain their previous access/duty behavior; test any optional gang selector with an actual member.

After deploying the matching Jobs Base and Firejob, save one Firejob setting, then one unrelated resource's setting. Confirm Fire equipment settings, item availability and Fire tablet access still follow the Firejob profile. Restart Firejob and recheck the saved value.

If a check fails, keep the update on staging and collect the installed resource versions, selected provider, effective saved setting and the first relevant startup or action error. A successful source test, build or copy does not establish live FiveM, provider or customer acceptance.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-09-29" title="Version 1.15.1">
<template v-slot:body="">

**Highlights**

- Fixed an issue where the Fire file explorer failed to open inside the shared tablet.

**Notable Changes**

- Changed Fire startup back to the previous shared-dependency loading behavior.
- Improved hose aiming synchronization and temporary pump and scenario-prop cleanup.

**Other Changes**

- Updated the bundled Hungarian translations.

**Changed Files**

- `sky_firejob/config/locales/*`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/source/*` — delete and reinsert

<update-guide from="1.15.0" resource="sky_firejob" to="1.15.1">
<template v-slot:simplified="">

1. **Prepare**

These instructions cover `sky_firejob` `1.15.0` → `1.15.1`. Complete earlier migrations first if upgrading from an older version. Back up the database, resources, custom configuration and saved job/Creator data. Stop the server for the coordinated update. Install Base `1.44.1`, then Jobs Base `1.47.1`, then the matching hotfixes for your installed Sky jobs and Crime.

1. **Replace files**

Use the `1.15.1` download. Delete the entire `sky_firejob/source/` folder and insert the new folder. Replace `sky_firejob/fxmanifest.lua` from that same package. Refresh the complete `sky_firejob/config/locales/` tree and reapply custom translations. Keep the new source and manifest together; do not merge old generated interface files into them.

1. **Keep settings**

No configuration values or Job Configurator setting keys are added, removed or reset by this hotfix. Keep your current settings and saved overrides. Hungarian uses the existing `Config.locale = "hu"` setting in `sky_base/config/config.lua`; leave your selected language unchanged if you do not want to switch. Update the matching Base, Jobs Base and installed resource locale folders together.

Optional diagnostics stay disabled by default. If support requests a recording, put `setr sky_profiler 1` before the Sky `ensure` lines in `server.cfg`, restart, run `profiler record 1000`, wait for `profiler status` to show completion, then run `profiler saveJSON sky-hotfix-profile.json`. Disable with `setr sky_profiler 0` and another restart. This is not a `/jobconfig` option; nothing is recorded or uploaded automatically.

1. **Data and assets**

No new SQL import, item definition, inventory image or stream asset is required for this hotfix. Keep saved job/Creator data; do not reset or reimport it. Required earlier migrations still apply when upgrading from an older release.

1. **Restart and check**

Start your framework, database connector and configured providers first, then Base `1.44.1`, Jobs Base `1.47.1` and the updated jobs/Crime. Reconnect clients. Open the Fire file explorer from the shared tablet and check hose aiming with another player, pump pickup and scenario-preview cleanup. If startup still fails, collect the first error and its preceding log lines together with the installed versions.

</template>

<template v-slot:prepare="">

These instructions cover `sky_firejob` `1.15.0` → `1.15.1`. Complete earlier migrations first if upgrading from an older version. Back up the database, resources, custom configuration and saved job/Creator data. Stop the server for the coordinated update. Install Base `1.44.1`, then Jobs Base `1.47.1`, then the matching hotfixes for your installed Sky jobs and Crime.

</template>

<template v-slot:files="">

Use the `1.15.1` download. Delete the entire `sky_firejob/source/` folder and insert the new folder. Replace `sky_firejob/fxmanifest.lua` from that same package. Refresh the complete `sky_firejob/config/locales/` tree and reapply custom translations. Keep the new source and manifest together; do not merge old generated interface files into them.

</template>

<template v-slot:config="">

No configuration values or Job Configurator setting keys are added, removed or reset by this hotfix. Keep your current settings and saved overrides. Hungarian uses the existing `Config.locale = "hu"` setting in `sky_base/config/config.lua`; leave your selected language unchanged if you do not want to switch. Update the matching Base, Jobs Base and installed resource locale folders together.

Optional diagnostics stay disabled by default. If support requests a recording, put `setr sky_profiler 1` before the Sky `ensure` lines in `server.cfg`, restart, run `profiler record 1000`, wait for `profiler status` to show completion, then run `profiler saveJSON sky-hotfix-profile.json`. Disable with `setr sky_profiler 0` and another restart. This is not a `/jobconfig` option; nothing is recorded or uploaded automatically.

</template>

<template v-slot:data="">

No new SQL import, item definition, inventory image or stream asset is required for this hotfix. Keep saved job/Creator data; do not reset or reimport it. Required earlier migrations still apply when upgrading from an older release.

</template>

<template v-slot:verify="">

Start your framework, database connector and configured providers first, then Base `1.44.1`, Jobs Base `1.47.1` and the updated jobs/Crime. Reconnect clients. Open the Fire file explorer from the shared tablet and check hose aiming with another player, pump pickup and scenario-preview cleanup. If startup still fails, collect the first error and its preceding log lines together with the installed versions.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-09-28" title="Version 1.15.0">
<template v-slot:body="">

**Highlights**

- Added editable SCBA refill-point appearance and interaction settings to the Job Configurator.
- Fixed an issue where saving automatic missions could lose the mission identity or apply an activation change to the wrong mission.

**Notable Changes**

- Fixed an issue where Fire station map icons ignored individual departments' saved names and display settings.
- Fixed an issue where fallen-tree marker, map-icon and interaction-range settings did not affect the active incident.
- Fixed an issue where fallen-tree cleanup tried to remove nearby map icons instead of only its own recorded icons.

**Other Changes**

- Added Hungarian translations for Fire menus and messages.
- Improved scene-visual cleanup when duty access changes, the player logs out or a tree incident enters its clearing phase.
- Improved startup dependency loading and database-wait diagnostics for protected resource packages.
- Improved keyboard selection and accessibility in shared tablet dropdowns.

**Changed Files**

- `sky_firejob/config/config.lua`
- `sky_firejob/config/locales/*`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/source/*` — delete and reinsert

<update-guide from="1.14.0" resource="sky_firejob" to="1.15.0">
<template v-slot:simplified="">

1. **Prepare the update**

These instructions cover `sky_firejob` `1.14.0` → `1.15.0`. Complete earlier required migrations first if upgrading from an older version. Stop the server for the coordinated update and back up the database, resource files, customized configuration and saved job/Creator data. Install Base `1.44.0` first, then Jobs Base `1.47.0`, then `sky_firejob` `1.15.0` and the matching updates for your other installed Sky jobs. The updated manifest requires the matching Base and Jobs Base imports; do not combine it with older dependency folders.

1. **Replace the package files**

Use the matching `1.15.0` package. Delete the complete old `sky_firejob/source/` folder and insert the new folder. Replace `sky_firejob/fxmanifest.lua` from the same download. Refresh the entire `sky_firejob/config/locales/` tree and merge your custom translations back. Do not merge old generated interface files into the new `source/` folder.

Merge the new SCBA interaction definition into `sky_firejob/config/config.lua` as described below. No SQL file, inventory definition or stream asset changes in this release, and no files outside `source/` are removed or renamed.

1. **Merge configuration and saved overrides**

**Hungarian language**

Refresh the complete resource locale folder from this download, including `hu.lua`, and carry over your custom translations. To use Hungarian, set the existing `Config.locale` value to `"hu"` in `sky_base/config/config.lua`; its supplied default remains `"en"`. Keep your current value if you are not changing language. This is the shared Sky language setting, so update the matching Base, Jobs Base and installed job locale folders together. Jobs Base supplies the Hungarian `/jobconfig` translations too. No new `/jobconfig` language setting, saved-job reset or database migration is required for this language addition. Apply the normal restart and reconnect steps at the end of this update.

**New plaintext block:** In `sky_firejob/config/config.lua`, `Config.Interactions.air_refill_station` was previously absent because the SCBA refill point was defined internally. Add this full block after `Config.FireStationBlip` if you do not already have a `Config.Interactions` table:

```lua
Config.Interactions = {
    air_refill_station = {
        marker = {
            enabled = true,
            type = 1,
            offset = vector3(0.0, 0.0, 0.0)
        },
        blip = {
            enabled = false,
            sprite = 361,
            color = 1
        },
        npc = {
            enabled = false
        },
        interactionDistance = 1.8
    }
}
```

If your file already defines `Config.Interactions`, insert only the `air_refill_station` entry into that table; do not replace your other entries. These values preserve the previous SCBA defaults: marker on, blip/NPC off, range 1.8. Labels continue to come from the installed locale unless deliberately customized. No existing config block is removed.

**With /jobconfig:** After starting the updated resources, open Fire → Interactions → SCBA refill station (`air_refill_station`). This is an interaction definition with saved interaction overrides, not a new standalone switch. Review marker, blip, NPC, label and distance in that editor; an old plaintext edit does not replace saved overrides. Existing refill locations remain in the Fire station's Locations area and do not need to be recreated.

**Station blips:** Existing `Config.FireStationBlip` and `Config.Jobs[*].blip` retain their values. Complete saved names, prefixes, visibility and display settings now take effect. New/imported jobs without their own blip inherit Fire Station Blip; existing per-job overrides stay authoritative. Review each department's blip in the job editor.

**Fallen trees:** `Config.TreeIncident` has no new required field or changed default. Existing marker/blip settings now render, and `interactionDistance` now controls the radial range instead of the old hardcoded 5.0. Its shipped value remains 2.5. Review the existing Trees settings: `treeEnabled`, `treeRequireOnDuty`, `treeInteractionDistance`, `treeBlipSprite`, `treeBlipColor`, `treeBlipScale`, `treeBlipLabel`, `treeMarkerType`, `treeMarkerSize`, `treeMarkerHeight`, `treeMarkerR`, `treeMarkerG`, `treeMarkerB`, `treeMarkerA`. An explicitly empty blip label and zero color/alpha values remain meaningful. Keep your saved overrides; tree activation stays in the radial menu.

**Automatic Missions:** Existing `scenarioAutomaticMissions` rows keep their mission keys when saved, including newly listed or differently ordered missions. No new setting key, mission import or data reset is needed. Reopen Automatic Missions, review the intended enabled states and save once if a previous attempt failed or affected the wrong row. Unrelated mission settings remain unchanged.

No `Config.Hose.vehicles` panel/intake/outlet changes, incident/reward configuration changes, extinguisher access-policy changes or breathing-bottle storage migration are introduced by `1.14.0` → `1.15.0`. The earlier bottle retrieval and SQL instructions apply only when upgrading through `1.14.0` from an older version.

**Optional performance diagnostics**

Extra profiler information remains disabled by default. If support requests a recording, add `setr sky_profiler 1` to `server.cfg` before the Sky `ensure` lines and restart the server. In the server console, run `profiler record 1000`, wait until `profiler status` reports completion, then run `profiler saveJSON sky-release-profile.json`. Share the file only when requested. To disable the extra information, change the line to `setr sky_profiler 0` and restart again. This is not a `/jobconfig` setting; enabling it does not record or upload anything automatically.

Keep `source/` and `fxmanifest.lua` from the same download even when diagnostics are disabled. Profiler processing changes only source Lua and the manifest. If an older profiler package changed public files outside `source/`, restore those files once from the clean current download and reapply your own customizations.

1. **Apply SQL, inventory and asset updates**

No Fire SQL migration, table/column type/default change, new item, inventory image, streamed model, hose-vehicle coordinate edit or permission-ID migration is required for this release. Keep existing saved missions, bottle storage and department data. The SCBA interaction block is configuration; it does not add another inventory item or require replacing refill locations.

1. **Restart and verify**

Start providers/framework, Base `1.44.0`, Jobs Base `1.47.0` and Fire `1.15.0`, then reconnect. Check the installed versions and resolve startup errors. Change one department's station blip, then change an SCBA point's label/marker/NPC and range; save/reopen and verify that its existing refill action still works.

During a test tree incident, check the saved scene visuals and radial range, duty loss, clearing phase and completion. Nearby unrelated map icons must remain. In Automatic Missions, change one mission's enabled state, save, reopen and restart; verify the same mission remains selected and other rows retain their settings. Check keyboard selection in tablet dropdowns. These are installation checks for your actual provider and game environment, separate from automated source tests.

</template>

<template v-slot:prepare="">

These instructions cover `sky_firejob` `1.14.0` → `1.15.0`. Complete earlier required migrations first if upgrading from an older version. Stop the server for the coordinated update and back up the database, resource files, customized configuration and saved job/Creator data. Install Base `1.44.0` first, then Jobs Base `1.47.0`, then `sky_firejob` `1.15.0` and the matching updates for your other installed Sky jobs. The updated manifest requires the matching Base and Jobs Base imports; do not combine it with older dependency folders.

</template>

<template v-slot:files="">

Use the matching `1.15.0` package. Delete the complete old `sky_firejob/source/` folder and insert the new folder. Replace `sky_firejob/fxmanifest.lua` from the same download. Refresh the entire `sky_firejob/config/locales/` tree and merge your custom translations back. Do not merge old generated interface files into the new `source/` folder.

Merge the new SCBA interaction definition into `sky_firejob/config/config.lua` as described below. No SQL file, inventory definition or stream asset changes in this release, and no files outside `source/` are removed or renamed.

</template>

<template v-slot:config="">

**Hungarian language**

Refresh the complete resource locale folder from this download, including `hu.lua`, and carry over your custom translations. To use Hungarian, set the existing `Config.locale` value to `"hu"` in `sky_base/config/config.lua`; its supplied default remains `"en"`. Keep your current value if you are not changing language. This is the shared Sky language setting, so update the matching Base, Jobs Base and installed job locale folders together. Jobs Base supplies the Hungarian `/jobconfig` translations too. No new `/jobconfig` language setting, saved-job reset or database migration is required for this language addition. Apply the normal restart and reconnect steps at the end of this update.

**New plaintext block:** In `sky_firejob/config/config.lua`, `Config.Interactions.air_refill_station` was previously absent because the SCBA refill point was defined internally. Add this full block after `Config.FireStationBlip` if you do not already have a `Config.Interactions` table:

```lua
Config.Interactions = {
    air_refill_station = {
        marker = {
            enabled = true,
            type = 1,
            offset = vector3(0.0, 0.0, 0.0)
        },
        blip = {
            enabled = false,
            sprite = 361,
            color = 1
        },
        npc = {
            enabled = false
        },
        interactionDistance = 1.8
    }
}
```

If your file already defines `Config.Interactions`, insert only the `air_refill_station` entry into that table; do not replace your other entries. These values preserve the previous SCBA defaults: marker on, blip/NPC off, range 1.8. Labels continue to come from the installed locale unless deliberately customized. No existing config block is removed.

**With /jobconfig:** After starting the updated resources, open Fire → Interactions → SCBA refill station (`air_refill_station`). This is an interaction definition with saved interaction overrides, not a new standalone switch. Review marker, blip, NPC, label and distance in that editor; an old plaintext edit does not replace saved overrides. Existing refill locations remain in the Fire station's Locations area and do not need to be recreated.

**Station blips:** Existing `Config.FireStationBlip` and `Config.Jobs[*].blip` retain their values. Complete saved names, prefixes, visibility and display settings now take effect. New/imported jobs without their own blip inherit Fire Station Blip; existing per-job overrides stay authoritative. Review each department's blip in the job editor.

**Fallen trees:** `Config.TreeIncident` has no new required field or changed default. Existing marker/blip settings now render, and `interactionDistance` now controls the radial range instead of the old hardcoded 5.0. Its shipped value remains 2.5. Review the existing Trees settings: `treeEnabled`, `treeRequireOnDuty`, `treeInteractionDistance`, `treeBlipSprite`, `treeBlipColor`, `treeBlipScale`, `treeBlipLabel`, `treeMarkerType`, `treeMarkerSize`, `treeMarkerHeight`, `treeMarkerR`, `treeMarkerG`, `treeMarkerB`, `treeMarkerA`. An explicitly empty blip label and zero color/alpha values remain meaningful. Keep your saved overrides; tree activation stays in the radial menu.

**Automatic Missions:** Existing `scenarioAutomaticMissions` rows keep their mission keys when saved, including newly listed or differently ordered missions. No new setting key, mission import or data reset is needed. Reopen Automatic Missions, review the intended enabled states and save once if a previous attempt failed or affected the wrong row. Unrelated mission settings remain unchanged.

No `Config.Hose.vehicles` panel/intake/outlet changes, incident/reward configuration changes, extinguisher access-policy changes or breathing-bottle storage migration are introduced by `1.14.0` → `1.15.0`. The earlier bottle retrieval and SQL instructions apply only when upgrading through `1.14.0` from an older version.

**Optional performance diagnostics**

Extra profiler information remains disabled by default. If support requests a recording, add `setr sky_profiler 1` to `server.cfg` before the Sky `ensure` lines and restart the server. In the server console, run `profiler record 1000`, wait until `profiler status` reports completion, then run `profiler saveJSON sky-release-profile.json`. Share the file only when requested. To disable the extra information, change the line to `setr sky_profiler 0` and restart again. This is not a `/jobconfig` setting; enabling it does not record or upload anything automatically.

Keep `source/` and `fxmanifest.lua` from the same download even when diagnostics are disabled. Profiler processing changes only source Lua and the manifest. If an older profiler package changed public files outside `source/`, restore those files once from the clean current download and reapply your own customizations.

</template>

<template v-slot:data="">

No Fire SQL migration, table/column type/default change, new item, inventory image, streamed model, hose-vehicle coordinate edit or permission-ID migration is required for this release. Keep existing saved missions, bottle storage and department data. The SCBA interaction block is configuration; it does not add another inventory item or require replacing refill locations.

</template>

<template v-slot:verify="">

Start providers/framework, Base `1.44.0`, Jobs Base `1.47.0` and Fire `1.15.0`, then reconnect. Check the installed versions and resolve startup errors. Change one department's station blip, then change an SCBA point's label/marker/NPC and range; save/reopen and verify that its existing refill action still works.

During a test tree incident, check the saved scene visuals and radial range, duty loss, clearing phase and completion. Nearby unrelated map icons must remain. In Automatic Missions, change one mission's enabled state, save, reopen and restart; verify the same mission remains selected and other rows retain their settings. Check keyboard selection in tablet dropdowns. These are installation checks for your actual provider and game environment, separate from automated source tests.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-09-24" title="Version 1.14.0">
<template v-slot:body="">

**Highlights**

- Improved vehicle breathing-bottle storage so bottle slots, pressure and item details can be restored after a restart for the same vehicle plate.

**Notable Changes**

- Changed empty interior-extinguisher job lists to allow every job while retaining the configured duty requirement and explicit exceptions.
- Fixed an issue where invoice receipts with an empty item list could fail to display.

**Other Changes**

- Added playback for video records opened in the shared document viewer.
- Fixed an issue where select menus inside dialogs could appear behind the dialog or lose its focus scope.
- Improved scaling of shared tablet controls, signatures and document views across screen resolutions.

**Changed Files**

- `sky_firejob/fxmanifest.lua`
- `sky_firejob/config/config.lua`
- `sky_firejob/import.sql`
- `sky_firejob/config/locales/*`
- `sky_firejob/source/*` — delete and reinsert

<update-guide from="1.13.0" resource="sky_firejob" to="1.14.0">
<template v-slot:simplified="">

1. **Prepare the update**

**Before stopping the old version, remove every breathing bottle from vehicle bottle storage.** Old live vehicle-state contents are not imported into the new storage. Already lost contents cannot be reconstructed.

These instructions cover `sky_firejob` `1.13.0` → `1.14.0`. Complete earlier required migrations first if upgrading from an older release. Stop the server for the coordinated update and back up the resource, database, customized configuration and saved job/creator settings. Install Base `1.43.0` first, then Jobs Base `1.46.0`, then the matching installed job releases.

1. **Replace the package files**

Use the matching `1.14.0` package. Delete the old `sky_firejob/source/` directory completely and insert the new directory. Replace `sky_firejob/fxmanifest.lua` from the same package. Refresh the entire `sky_firejob/config/locales/` tree and merge your custom translations back. Replace `sky_firejob/import.sql` and merge the `config/config.lua` access-policy comment and settings described here. Merely copying SQL does not execute it.

Do not merge old generated interface files into the new `source/` directory.

1. **Merge configuration and saved overrides**

Prepare file changes while the server is stopped. Perform the `/jobconfig`, Creator and other in-game actions described in this section **after starting the updated resources in step 5**, during maintenance and before admitting players.

Path: `sky_firejob/config/config.lua`, `Config.InteriorExtinguishers.allowedJobs`.

Old line:

```lua
allowedJobs = {},
```

New line:

```lua
allowedJobs = {}, -- Empty allows every job; requireOnDuty still applies.
```

The value is unchanged; behavior changes. Previously an empty list fell back to configured Fire jobs. It now accepts any job subject to duty rules. The unchanged relevant shipped values are:

```lua
requireOnDuty = true,
noDutyJobs = { "unemployed" },
allowedJobs = {},
```

`noDutyJobs` is checked first: listed jobs bypass both the duty requirement and the normal allowed-job filter. This is an explicit exception list, not just another default allowed-job list. To allow unrestricted pickup/restocking use `allowedJobs = {}` and `requireOnDuty = false`. To retain a department-only policy, provide your actual department job names in `allowedJobs` and review `noDutyJobs`; do not silently remove an intentional exception.

Exact `/jobconfig` resource/section: `sky_firejob`, Interior Extinguishers -> General -> Access. Keys: `interiorExtinguishersAllowedJobs`, `interiorExtinguishersRequireOnDuty`, `interiorExtinguishersNoDutyJobs`. The first and third are job rows converted to/from string lists. Saved values remain overrides; the empty saved list gets the new empty-list meaning. Placement and maintenance permissions are unchanged. No new setting key is introduced.

**Optional Lore Billing**

With Base 1.43.0, use the existing provider setting in `sky_base/config/config.lua`: change `Config.billing` from `"auto"`/your selected provider to `"lore"` for an explicit choice, or keep `"auto"` when Lore should be detected. Start `lore-billing` before Sky Base so automatic detection sees it. Install/retain Lore's own documented setup separately; Fire does not install the provider or its schema.

Fire's existing shipped default in `sky_firejob/config/config.lua` remains `Config.Billing.mode = "consent"`. To send through Lore, deliberately select `"framework"` instead. This is an optional setup choice; the Fire default remains unchanged.

Without `/jobconfig`:

```lua
Config.Billing = {
    enabled = true,
    mode = "framework", -- previously "consent" if using the shipped default
    range = 6.0,
    maxAmount = 50000,
    reasons = {} -- Preserve your own existing presets.
}
```

This block shows the existing defaults with only the mode switched; keep custom range, maximum and reasons instead of replacing them. With `/jobconfig`, set Billing mode to Framework using exact key `fireBillingMode`; verify `fireBillingEnabled` is true. A saved `fireBillingMode` override takes precedence over a plaintext edit. `billing.mode` is **not** the Fire setting key.

Fire validates staff access, target distance, integer amount and reason. The configured department needs a valid society account. The new Base adapter relays a society invoice through the online issuing player's Lore client context and needs issuer and recipient online. Dispatch is not a provider persistence acknowledgment; the Sky return value alone does not confirm a stored invoice. Verify actual invoice delivery in Lore during the installation check.

The verified Lore version requires Qbox (`qbx_core`), `ox_lib`, `oxmysql` and `Renewed-Banking`. Install/start those dependencies before Lore. The Sky adapter does not add another framework bridge to the external provider.

**Optional performance diagnostics**

Extra profiler information is disabled by default. If support requests a recording, add `setr sky_profiler 1` to `server.cfg` before the Sky `ensure` lines and restart. In the server console, run `profiler record 1000`, wait until `profiler status` reports completion, then run `profiler saveJSON sky-release-profile.json`. To disable the extra information, use `setr sky_profiler 0` and restart. This is not a `/jobconfig` setting. Enabling it does not start recording or upload anything automatically.

Keep `source/` and `fxmanifest.lua` from the same download even when diagnostics are disabled. Profiler processing changes only source Lua and the manifest; public configuration and provider files remain unchanged by that processing. If an older profiler package altered files outside `source/`, restore those once from the current download and reapply your own customizations.

1. **Apply SQL, inventory and asset updates**

New table, created automatically or with this manual SQL block:

```sql
CREATE TABLE IF NOT EXISTS `sky_fire_air_storage` (
    `plate` VARCHAR(64) NOT NULL,
    `slots` LONGTEXT NOT NULL,
    PRIMARY KEY (`plate`)
) ENGINE=InnoDB;
```

Neither column has a default; neither path forces charset/collation. Existing `Config.AutoExecuteQuery = true` creates the table on startup. With `false`, run that single CREATE TABLE statement manually before starting the updated Fire resource. `/jobconfig` does not install SQL.

Old entity-state storage is deliberately not imported. Owners **must retrieve bottles before the first update/restart of the old implementation** if they want to preserve those live contents. Already lost old contents cannot be reconstructed. New storage uses the uppercase plate with all whitespace removed; stable unique plates matter. Changing the plate selects different storage; two vehicles with the same normalized plate share that storage identity. Existing vehicle model/slot-count configuration is unchanged, and slots temporarily above capacity are retained in SQL.

No `Config.Hose.vehicles` panel/intake/outlet edits, incident/reward changes, inventory item additions, new images, stream files or permission-ID migration occur in this release. Complete older migrations separately only when upgrading from an earlier version.

1. **Restart and verify**

Start providers/framework, Base `1.43.0`, Jobs Base `1.46.0` and Fire `1.14.0`, then reconnect and check SQL startup errors. Return the retrieved bottles after startup. Store a partly used bottle in a non-first slot, restart the resource and then server, respawn the same plate and retrieve it once. Check pressure and another player attempting the same slot. Test an ordinary job against your selected extinguisher access policy. Check invoice receipts and, if selected, actual delivery in Lore. These are installation checks to perform on your server.

</template>

<template v-slot:prepare="">

**Before stopping the old version, remove every breathing bottle from vehicle bottle storage.** Old live vehicle-state contents are not imported into the new storage. Already lost contents cannot be reconstructed.

These instructions cover `sky_firejob` `1.13.0` → `1.14.0`. Complete earlier required migrations first if upgrading from an older release. Stop the server for the coordinated update and back up the resource, database, customized configuration and saved job/creator settings. Install Base `1.43.0` first, then Jobs Base `1.46.0`, then the matching installed job releases.

</template>

<template v-slot:files="">

Use the matching `1.14.0` package. Delete the old `sky_firejob/source/` directory completely and insert the new directory. Replace `sky_firejob/fxmanifest.lua` from the same package. Refresh the entire `sky_firejob/config/locales/` tree and merge your custom translations back. Replace `sky_firejob/import.sql` and merge the `config/config.lua` access-policy comment and settings described here. Merely copying SQL does not execute it.

Do not merge old generated interface files into the new `source/` directory.

</template>

<template v-slot:config="">

Prepare file changes while the server is stopped. Perform the `/jobconfig`, Creator and other in-game actions described in this section **after starting the updated resources in step 5**, during maintenance and before admitting players.

Path: `sky_firejob/config/config.lua`, `Config.InteriorExtinguishers.allowedJobs`.

Old line:

```lua
allowedJobs = {},
```

New line:

```lua
allowedJobs = {}, -- Empty allows every job; requireOnDuty still applies.
```

The value is unchanged; behavior changes. Previously an empty list fell back to configured Fire jobs. It now accepts any job subject to duty rules. The unchanged relevant shipped values are:

```lua
requireOnDuty = true,
noDutyJobs = { "unemployed" },
allowedJobs = {},
```

`noDutyJobs` is checked first: listed jobs bypass both the duty requirement and the normal allowed-job filter. This is an explicit exception list, not just another default allowed-job list. To allow unrestricted pickup/restocking use `allowedJobs = {}` and `requireOnDuty = false`. To retain a department-only policy, provide your actual department job names in `allowedJobs` and review `noDutyJobs`; do not silently remove an intentional exception.

Exact `/jobconfig` resource/section: `sky_firejob`, Interior Extinguishers -> General -> Access. Keys: `interiorExtinguishersAllowedJobs`, `interiorExtinguishersRequireOnDuty`, `interiorExtinguishersNoDutyJobs`. The first and third are job rows converted to/from string lists. Saved values remain overrides; the empty saved list gets the new empty-list meaning. Placement and maintenance permissions are unchanged. No new setting key is introduced.

**Optional Lore Billing**

With Base 1.43.0, use the existing provider setting in `sky_base/config/config.lua`: change `Config.billing` from `"auto"`/your selected provider to `"lore"` for an explicit choice, or keep `"auto"` when Lore should be detected. Start `lore-billing` before Sky Base so automatic detection sees it. Install/retain Lore's own documented setup separately; Fire does not install the provider or its schema.

Fire's existing shipped default in `sky_firejob/config/config.lua` remains `Config.Billing.mode = "consent"`. To send through Lore, deliberately select `"framework"` instead. This is an optional setup choice; the Fire default remains unchanged.

Without `/jobconfig`:

```lua
Config.Billing = {
    enabled = true,
    mode = "framework", -- previously "consent" if using the shipped default
    range = 6.0,
    maxAmount = 50000,
    reasons = {} -- Preserve your own existing presets.
}
```

This block shows the existing defaults with only the mode switched; keep custom range, maximum and reasons instead of replacing them. With `/jobconfig`, set Billing mode to Framework using exact key `fireBillingMode`; verify `fireBillingEnabled` is true. A saved `fireBillingMode` override takes precedence over a plaintext edit. `billing.mode` is **not** the Fire setting key.

Fire validates staff access, target distance, integer amount and reason. The configured department needs a valid society account. The new Base adapter relays a society invoice through the online issuing player's Lore client context and needs issuer and recipient online. Dispatch is not a provider persistence acknowledgment; the Sky return value alone does not confirm a stored invoice. Verify actual invoice delivery in Lore during the installation check.

The verified Lore version requires Qbox (`qbx_core`), `ox_lib`, `oxmysql` and `Renewed-Banking`. Install/start those dependencies before Lore. The Sky adapter does not add another framework bridge to the external provider.

**Optional performance diagnostics**

Extra profiler information is disabled by default. If support requests a recording, add `setr sky_profiler 1` to `server.cfg` before the Sky `ensure` lines and restart. In the server console, run `profiler record 1000`, wait until `profiler status` reports completion, then run `profiler saveJSON sky-release-profile.json`. To disable the extra information, use `setr sky_profiler 0` and restart. This is not a `/jobconfig` setting. Enabling it does not start recording or upload anything automatically.

Keep `source/` and `fxmanifest.lua` from the same download even when diagnostics are disabled. Profiler processing changes only source Lua and the manifest; public configuration and provider files remain unchanged by that processing. If an older profiler package altered files outside `source/`, restore those once from the current download and reapply your own customizations.

</template>

<template v-slot:data="">

New table, created automatically or with this manual SQL block:

```sql
CREATE TABLE IF NOT EXISTS `sky_fire_air_storage` (
    `plate` VARCHAR(64) NOT NULL,
    `slots` LONGTEXT NOT NULL,
    PRIMARY KEY (`plate`)
) ENGINE=InnoDB;
```

Neither column has a default; neither path forces charset/collation. Existing `Config.AutoExecuteQuery = true` creates the table on startup. With `false`, run that single CREATE TABLE statement manually before starting the updated Fire resource. `/jobconfig` does not install SQL.

Old entity-state storage is deliberately not imported. Owners **must retrieve bottles before the first update/restart of the old implementation** if they want to preserve those live contents. Already lost old contents cannot be reconstructed. New storage uses the uppercase plate with all whitespace removed; stable unique plates matter. Changing the plate selects different storage; two vehicles with the same normalized plate share that storage identity. Existing vehicle model/slot-count configuration is unchanged, and slots temporarily above capacity are retained in SQL.

No `Config.Hose.vehicles` panel/intake/outlet edits, incident/reward changes, inventory item additions, new images, stream files or permission-ID migration occur in this release. Complete older migrations separately only when upgrading from an earlier version.

</template>

<template v-slot:verify="">

Start providers/framework, Base `1.43.0`, Jobs Base `1.46.0` and Fire `1.14.0`, then reconnect and check SQL startup errors. Return the retrieved bottles after startup. Store a partly used bottle in a non-first slot, restart the resource and then server, respawn the same plate and retrieve it once. Check pressure and another player attempting the same slot. Test an ordinary job against your selected extinguisher access policy. Check invoice receipts and, if selected, actual delivery in Lore. These are installation checks to perform on your server.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-09-22" title="Version 1.13.0">
<template v-slot:body="">
<callout color="warning" icon="i-lucide-triangle-alert">

Update Base to `1.42.0` and Jobs Base to `1.45.0` before installing Firejob `1.13.0`.

</callout>

**Highlights**

- Added Fire department invoices from the radial menu, with a paper preview, multiple preset reasons and recipient payment by Cash or Card.
- Added File Explorer to the Fire tablet, bringing Incident Reports and documents shared by other departments into one place.
- Added Print and Share actions for saved incident reports, including explicit recipient selection and read-only access for receiving jobs.

**Notable Changes**

- Fixed an issue where simultaneous report edits or sharing changes could overwrite another user's work; conflicting saves now retain the draft and offer the current report.
- Improved civilian references in incident reports so selected characters can be linked accurately while existing written names remain readable.
- Optimized scenario loading, Fire settings and extinguisher updates to transfer changed information instead of repeatedly sending complete collections.
- Improved incident-report spacing, tags and controls inside File Explorer.

**Other Changes**

- Improved form readability on large displays and kept selection lists above open dialogs.
- Updated the oil-spill setting description to explain that automatic collision and wear spills require a connected vehicle system.
- Added translated invoice, Explorer, sharing and report-conflict messages in all bundled languages.

**Changed Files**

- `sky_firejob/config/config.lua`
- `sky_firejob/config/locales/*`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/import.sql`
- `sky_firejob/source/*` — delete and reinsert

<update-guide from="1.12.0" resource="sky_firejob" to="1.13.0">
<template v-slot:simplified="">

1. **Prepare the update**

These instructions cover `1.12.0` → `1.13.0`. Complete earlier migrations first if upgrading from an older version. Stop the server and back up the database, resource, custom configuration and saved creator/configurator data. Update `sky_base` to `1.42.0`, then `sky_jobs_base` to `1.45.0`, including their own migration and inventory steps, before Firejob.

1. **Replace the package files**

Install the matching `1.13.0` download. Delete and reinsert `sky_firejob/source/*`; replace `sky_firejob/fxmanifest.lua`, `sky_firejob/import.sql` and the complete `sky_firejob/config/locales/*`. Merge the Billing block into your customized `sky_firejob/config/config.lua`. Preserve other customized configuration, saved scenarios and assets. There are no removed or renamed customer paths outside `source/` in this release.

Use `source/*` and `fxmanifest.lua` from the same download even with diagnostics disabled. Profiler builds may instrument only Lua inside `source/` and the manifest. If an older profiler package changed public files, restore those once from the clean new package and reapply your customizations. The new invoice graphics and Explorer UI are included in `source/*`; no separate Fire stream or inventory assets are added.

1. **Merge configuration and check access**

Merge the new complete block into `sky_firejob/config/config.lua`; `Config.Billing` did not exist in `1.12.0`:

```lua
Config.Billing = {
    enabled = true,
    mode = "consent",
    range = 6.0,
    maxAmount = 50000,
    reasons = {}
}
```

`enabled` allows invoices; `mode = "consent"` lets the recipient choose Cash or Card or decline; `range` is the maximum recipient distance in metres; `maxAmount` caps a whole-number invoice total. An empty `reasons` list means there are no preset reasons: staff can enter a reason manually. To add presets, use entries such as `{ reason = "Service description", amount = 100 }`; multiple presets and notes can be combined.

With `/jobconfig`, open Fire → Billing and review `fireBillingEnabled`, `fireBillingMode`, `fireBillingRange`, `fireBillingMaxAmount` and `fireBillingReasons`. Their defaults are respectively `true`, `"consent"`, `6.0`, `50000` and an empty list. Saved overrides remain effective. Development-era `"instant"` values automatically become `"consent"`; no automatic debit mode remains. `"framework"` explicitly uses the billing provider selected in Sky Base. Verify each issuing job's existing society account; internal payments need the configured banking integration to credit that account. Issuing an external invoice does not prove it was paid.

**File Explorer and report access**

The Fire tablet now opens File Explorer, with Incident Reports as a directory. The existing Fire job, duty and tablet-app restrictions apply; no new Fire permission ID is required. Review restrictions for `fire_files` and `fire_reports` if your server limits tablet apps by rank. Reports received from another job appear in Shared Documents and remain read-only. Save an owned incident report before using Print or Share. Share explicitly selects registered recipient jobs, and removing a recipient revokes its digital access. Existing per-report recipient lists are retained; old job-wide record-sharing rules no longer grant access. Check the recipients of existing reports rather than deleting or reimporting them. Selected civilians are linked by their verified character identity; older free-text names remain descriptive.

The Explorer itself needs no additional Fire configuration, item, asset or Creator import after installing the coordinated release and SQL. DOJ is optional: its documents appear only when the corresponding resource and authorized shares are available. Normal Fire reports, sharing and printing do not require DOJ.

For printing, complete the Jobs Base `1.45.0` printer and inventory update: register `job_document` with its supplied image in a metadata-capable inventory, retain or configure an accessible printer, and provide its configured paper. The printed item is a permanent copy of the saved report; revoking a digital share does not recall an already printed copy. Optional document images are configured in Jobs Base's `Config.Printers.documentAppearance` or the job's `/jobconfig` document-appearance extension, not in Fire's `Config.Reports`.

No Fire job lists, incident/reward settings or `Config.Hose.vehicles` fields change in this release. Keep existing pump panel, intake and outlet calibration. The oil-spill setting only enables spills, slipping and cleanup; automatic collision or wear triggers still require Sky Mechanic or another connected resource.

**Optional performance diagnostics**

The optional profiler is disabled by default. To make a support recording, put `setr sky_profiler 1` in `server.cfg` before the Sky `ensure` lines and restart. Run `profiler record 1000` in the server console, wait until `profiler status` reports completion, then run `profiler saveJSON sky-release-profile.json`. Share that file only when requested. Set `setr sky_profiler 0` and restart to disable the extra information. This is not a `/jobconfig` setting and does not start recordings or upload data automatically.

1. **Apply SQL, items and assets**

**SQL:** The Fire report table needs a wider report ID and separate report/sharing revision counters. With `Config.AutoExecuteQuery = true`, allow the normal startup migration to finish. If automatic migration is disabled, run this non-destructive block from `sky_firejob/import.sql` against the existing database before starting Firejob:

```sql
ALTER TABLE `sky_fire_reports`
    MODIFY `report_id` VARCHAR(40) NOT NULL,
    ADD COLUMN IF NOT EXISTS `revision` INT NOT NULL DEFAULT 1,
    ADD COLUMN IF NOT EXISTS `share_revision` INT NOT NULL DEFAULT 1;
```

The old `report_id` was `VARCHAR(32)`; both revision columns are new. Existing reports and explicit recipients remain in place. Do not clear the table. Also complete the Jobs Base `1.45.0` migrations for shared and printed documents.

**Items and assets:** Fire adds no standalone item, image or stream file. Optional report printing uses the Jobs Base `job_document` item, supplied image, metadata-capable inventory, accessible printer and its paper supply. Invoice payment uses its own on-screen receipt and does not require the report-printing item. Keep existing Fire inventories and scenario data; no Fire Creator import is required.

1. **Restart and verify**

Start database, framework and configured inventory/provider resources first, then Base `1.42.0`, Jobs Base `1.45.0`, Firejob `1.13.0` and the remaining updated jobs. Resolve startup/SQL errors before allowing normal play. Confirm Fire Explorer opens, Incident Reports retains existing records, and app restrictions still apply. Save and edit a report with two authorized users: a stale save should show a conflict while retaining the draft. Share a saved report with a second job, read it there, revoke access and check that the digital copy disappears. Print a report through an available printer and open the resulting item if printing is enabled. Test Cash, Card, decline and insufficient funds with two players, checking the society balance and Boss Menu payment entry; test the external provider separately if selected. Check scenario editing and fire-extinguisher pickup/restock after reconnecting.

</template>

<template v-slot:prepare="">

These instructions cover `1.12.0` → `1.13.0`. Complete earlier migrations first if upgrading from an older version. Stop the server and back up the database, resource, custom configuration and saved creator/configurator data. Update `sky_base` to `1.42.0`, then `sky_jobs_base` to `1.45.0`, including their own migration and inventory steps, before Firejob.

</template>

<template v-slot:files="">

Install the matching `1.13.0` download. Delete and reinsert `sky_firejob/source/*`; replace `sky_firejob/fxmanifest.lua`, `sky_firejob/import.sql` and the complete `sky_firejob/config/locales/*`. Merge the Billing block into your customized `sky_firejob/config/config.lua`. Preserve other customized configuration, saved scenarios and assets. There are no removed or renamed customer paths outside `source/` in this release.

Use `source/*` and `fxmanifest.lua` from the same download even with diagnostics disabled. Profiler builds may instrument only Lua inside `source/` and the manifest. If an older profiler package changed public files, restore those once from the clean new package and reapply your customizations. The new invoice graphics and Explorer UI are included in `source/*`; no separate Fire stream or inventory assets are added.

</template>

<template v-slot:config="">

Merge the new complete block into `sky_firejob/config/config.lua`; `Config.Billing` did not exist in `1.12.0`:

```lua
Config.Billing = {
    enabled = true,
    mode = "consent",
    range = 6.0,
    maxAmount = 50000,
    reasons = {}
}
```

`enabled` allows invoices; `mode = "consent"` lets the recipient choose Cash or Card or decline; `range` is the maximum recipient distance in metres; `maxAmount` caps a whole-number invoice total. An empty `reasons` list means there are no preset reasons: staff can enter a reason manually. To add presets, use entries such as `{ reason = "Service description", amount = 100 }`; multiple presets and notes can be combined.

With `/jobconfig`, open Fire → Billing and review `fireBillingEnabled`, `fireBillingMode`, `fireBillingRange`, `fireBillingMaxAmount` and `fireBillingReasons`. Their defaults are respectively `true`, `"consent"`, `6.0`, `50000` and an empty list. Saved overrides remain effective. Development-era `"instant"` values automatically become `"consent"`; no automatic debit mode remains. `"framework"` explicitly uses the billing provider selected in Sky Base. Verify each issuing job's existing society account; internal payments need the configured banking integration to credit that account. Issuing an external invoice does not prove it was paid.

**File Explorer and report access**

The Fire tablet now opens File Explorer, with Incident Reports as a directory. The existing Fire job, duty and tablet-app restrictions apply; no new Fire permission ID is required. Review restrictions for `fire_files` and `fire_reports` if your server limits tablet apps by rank. Reports received from another job appear in Shared Documents and remain read-only. Save an owned incident report before using Print or Share. Share explicitly selects registered recipient jobs, and removing a recipient revokes its digital access. Existing per-report recipient lists are retained; old job-wide record-sharing rules no longer grant access. Check the recipients of existing reports rather than deleting or reimporting them. Selected civilians are linked by their verified character identity; older free-text names remain descriptive.

The Explorer itself needs no additional Fire configuration, item, asset or Creator import after installing the coordinated release and SQL. DOJ is optional: its documents appear only when the corresponding resource and authorized shares are available. Normal Fire reports, sharing and printing do not require DOJ.

For printing, complete the Jobs Base `1.45.0` printer and inventory update: register `job_document` with its supplied image in a metadata-capable inventory, retain or configure an accessible printer, and provide its configured paper. The printed item is a permanent copy of the saved report; revoking a digital share does not recall an already printed copy. Optional document images are configured in Jobs Base's `Config.Printers.documentAppearance` or the job's `/jobconfig` document-appearance extension, not in Fire's `Config.Reports`.

No Fire job lists, incident/reward settings or `Config.Hose.vehicles` fields change in this release. Keep existing pump panel, intake and outlet calibration. The oil-spill setting only enables spills, slipping and cleanup; automatic collision or wear triggers still require Sky Mechanic or another connected resource.

**Optional performance diagnostics**

The optional profiler is disabled by default. To make a support recording, put `setr sky_profiler 1` in `server.cfg` before the Sky `ensure` lines and restart. Run `profiler record 1000` in the server console, wait until `profiler status` reports completion, then run `profiler saveJSON sky-release-profile.json`. Share that file only when requested. Set `setr sky_profiler 0` and restart to disable the extra information. This is not a `/jobconfig` setting and does not start recordings or upload data automatically.

</template>

<template v-slot:data="">

**SQL:** The Fire report table needs a wider report ID and separate report/sharing revision counters. With `Config.AutoExecuteQuery = true`, allow the normal startup migration to finish. If automatic migration is disabled, run this non-destructive block from `sky_firejob/import.sql` against the existing database before starting Firejob:

```sql
ALTER TABLE `sky_fire_reports`
    MODIFY `report_id` VARCHAR(40) NOT NULL,
    ADD COLUMN IF NOT EXISTS `revision` INT NOT NULL DEFAULT 1,
    ADD COLUMN IF NOT EXISTS `share_revision` INT NOT NULL DEFAULT 1;
```

The old `report_id` was `VARCHAR(32)`; both revision columns are new. Existing reports and explicit recipients remain in place. Do not clear the table. Also complete the Jobs Base `1.45.0` migrations for shared and printed documents.

**Items and assets:** Fire adds no standalone item, image or stream file. Optional report printing uses the Jobs Base `job_document` item, supplied image, metadata-capable inventory, accessible printer and its paper supply. Invoice payment uses its own on-screen receipt and does not require the report-printing item. Keep existing Fire inventories and scenario data; no Fire Creator import is required.

</template>

<template v-slot:verify="">

Start database, framework and configured inventory/provider resources first, then Base `1.42.0`, Jobs Base `1.45.0`, Firejob `1.13.0` and the remaining updated jobs. Resolve startup/SQL errors before allowing normal play. Confirm Fire Explorer opens, Incident Reports retains existing records, and app restrictions still apply. Save and edit a report with two authorized users: a stale save should show a conflict while retaining the draft. Share a saved report with a second job, read it there, revoke access and check that the digital copy disappears. Print a report through an available printer and open the resulting item if printing is enabled. Test Cash, Card, decline and insufficient funds with two players, checking the society balance and Boss Menu payment entry; test the external provider separately if selected. Check scenario editing and fire-extinguisher pickup/restock after reconnecting.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-09-19" title="Version 1.12.0">
<template v-slot:body="">
<callout color="warning" icon="i-lucide-triangle-alert">

Update Base to `1.41.0` and Jobs Base to `1.44.0` before installing `sky_firejob` `1.12.0`.

</callout>

**Highlights**

- Added selectable flame and smoke styles to the fire menu and mission creator, including natural, colored and vehicle-fire variants.
- Added growing menu fires with a configurable starting size and time to reach their full size.
- Added directional fire sounds that follow the fire location, with configurable volume and audible distance.
- Added live controls for flame size, smoke size, smoke opacity and smoke response to wind.

**Notable Changes**

- Improved fire placement so flames and mission previews retain their selected contact point on the ground or a wall.
- Fixed an issue where fire could spread without a verified surface or continue spreading away from a wall into open air.
- Improved large-incident rendering with shared flame and smoke limits that leave room for firefighting water effects.
- Optimized fire and hazard checks for scenes containing many or distant fires.
- Added a configurable server-side Dispatch integration for individual fires and missions.
- Changed the default vehicle-fire appearance to use the new vehicle flame style and removed bus shells from the random vehicle-wreck pool.

**Other Changes**

- Improved smoke appearance with denser columns and wind behavior that follows the selected visual preset.
- Fixed an issue where fire HUD panels could leave opaque rectangles around their warnings in FiveM.
- Fixed an issue where reloading a packaged Fire tablet page could lose its route.
- Added translations for the new fire-effect controls in all 15 supported languages, with English fallback for older untranslated Fire text.

**Changed Files**

- `sky_firejob/config/config.lua`
- `sky_firejob/config/locales/*`
- `sky_firejob/config/sv_functions.lua`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/source/*` — delete and reinsert
- `sky_firejob/stream/particles/sky_firejob.ypt`
- `sky_firejob/stream/particles/sky_firejob_cool.ypt`
- `sky_firejob/stream/particles/sky_firejob_green.ypt`
- `sky_firejob/stream/particles/sky_firejob_natural.ypt`
- `sky_firejob/stream/particles/sky_firejob_smoke_dense.ypt`
- `sky_firejob/stream/particles/sky_firejob_smoke_thick.ypt`
- `sky_firejob/stream/particles/sky_firejob_vehicle.ypt`

<update-guide from="1.11.0" resource="sky_firejob" to="1.12.0">
<template v-slot:simplified="">

1. **Prepare the update**

Update Base to `1.41.0` and Jobs Base to `1.44.0` before installing `sky_firejob` `1.12.0`. These instructions cover `1.11.0` → `1.12.0`; complete earlier migrations first when upgrading from an older version. Stop the server and back up the resource, database, customized files and saved configurator/creator data.

1. **Replace the package files**

Install the matching `1.12.0` download. Update every path in **Changed Files**, delete and reinsert `sky_firejob/source/*`, and replace `sky_firejob/config/locales/*` completely. Remove the exact paths under **Removed Files** and apply any listed renames. Preserve unrelated files, writable data and custom assets; merge the configuration changes in this tab into your customized public files.

Replace `source/*` and `fxmanifest.lua` from the same download even when optional diagnostics remain off. Profiler instrumentation is confined to Lua in `source/` and the generated manifest. Public configuration, integration and compatibility files match the uninstrumented source; their functional changes are listed separately for this release. If an older profiler package modified public files, restore those once from the clean new package and reapply your own edits.

1. **Merge configuration**

Merge these changes into `sky_firejob/config/config.lua`. With `/jobconfig`, use Fire → Settings → Fire system; the exact stored keys are listed below. Saved overrides remain authoritative. Appearance controls do not change smoke-poisoning strength.

<table>
<thead>
  <tr>
    <th>
      File path under <code>
        Config.FireSystem
      </code>
    </th>
    
    <th>
      Previous value
    </th>
    
    <th>
      New value
    </th>
    
    <th>
      <code>
        /jobconfig
      </code>
      
       key
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      <code>
        render.flameScaleMultiplier
      </code>
    </td>
    
    <td>
      Absent
    </td>
    
    <td>
      <code>
        1.0
      </code>
    </td>
    
    <td>
      <code>
        fireFlameScaleMultiplier
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        render.smokeScaleMultiplier
      </code>
    </td>
    
    <td>
      Absent
    </td>
    
    <td>
      <code>
        1.0
      </code>
    </td>
    
    <td>
      <code>
        fireSmokeScaleMultiplier
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        render.smokeDensityMultiplier
      </code>
    </td>
    
    <td>
      Absent
    </td>
    
    <td>
      <code>
        1.0
      </code>
    </td>
    
    <td>
      <code>
        fireSmokeDensityMultiplier
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        render.smokeWindResponse
      </code>
    </td>
    
    <td>
      Absent
    </td>
    
    <td>
      <code>
        "normal"
      </code>
    </td>
    
    <td>
      <code>
        fireSmokeWindResponse
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        ignition.startScale
      </code>
    </td>
    
    <td>
      Absent
    </td>
    
    <td>
      <code>
        0.2
      </code>
    </td>
    
    <td>
      <code>
        fireIgnitionStartScale
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        ignition.growthSeconds
      </code>
    </td>
    
    <td>
      Absent
    </td>
    
    <td>
      <code>
        40.0
      </code>
    </td>
    
    <td>
      <code>
        fireIgnitionGrowthSeconds
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        effects.sounds.fireAmbient.volume
      </code>
    </td>
    
    <td>
      <code>
        1.0
      </code>
    </td>
    
    <td>
      <code>
        0.65
      </code>
    </td>
    
    <td>
      <code>
        fireSoundFireAmbientVolume
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        effects.sounds.fireAmbient.range
      </code>
    </td>
    
    <td>
      <code>
        10.0
      </code>
    </td>
    
    <td>
      <code>
        40.0
      </code>
    </td>
    
    <td>
      <code>
        fireSoundFireAmbientRange
      </code>
    </td>
  </tr>
</tbody>
</table>

The ambient-sound switch remains enabled by default (`fireSoundFireAmbientEnabled`). Wind choices are `none`, `gentle`, `normal` and `strong`; the new choice applies to packaged smoke. Add the new ignition table and render values, and change the two sound values inside their existing parents:

```lua
Config.FireSystem.render.flameScaleMultiplier = 1.0
Config.FireSystem.render.smokeScaleMultiplier = 1.0
Config.FireSystem.render.smokeDensityMultiplier = 1.0
Config.FireSystem.render.smokeWindResponse = "normal"
Config.FireSystem.ignition = {
    startScale = 0.2,
    growthSeconds = 40.0,
}
Config.FireSystem.effects.sounds.fireAmbient.volume = 0.65
Config.FireSystem.effects.sounds.fireAmbient.range = 40.0
```

The shared Fire defaults also add client-wide visual limits of `96` flame sources and `24` smoke sources, exposed as `fireMaxFlameSources` and `fireMaxSmokeSources`. File-based servers may override `Config.FireSystem.render.maxFlameSources` and `Config.FireSystem.render.maxSmokeSources`; otherwise the shared defaults supply them. These limit visible effects, not the number of saved incidents. Flame and smoke visibility distances remain 1000 m in the shipped file; the existing shared visibility setting controls both when `/jobconfig` is used.

The new `sky_firejob/config/sv_functions.lua` supplies the Dispatch hook. Install the complete file. Its default continues to send alerts through Jobs Base, so no external provider is required. Only customize `Config.Functions.sendDispatch` if forwarding alerts to another system; retain the documented success/failure result and handle that provider's alert cleanup. This Lua function remains file-based and is intentionally outside `/jobconfig`.

Choose flame and smoke variants in `/skyfiremenu` or in the mission creator. Existing saved missions keep their choices/default profiles; do not delete or reimport them to obtain the new selectors. Starting size and growth duration affect newly created menu fires. No job list, incident-reward setting or hose-vehicle geometry changes in this release.

**Optional performance diagnostics**

Extra profiler information remains disabled by default. For a support recording, add `setr sky_profiler 1` to `server.cfg` before the Sky `ensure` lines and restart the server. In the server console, run `profiler record 1000`, wait for `profiler status` to report completion, then run `profiler saveJSON sky-release-profile.json`. Share that file when requested by support. Set `setr sky_profiler 0` and restart again to disable the extra information. This is not a `/jobconfig` setting; enabling it does not start a recording or upload data automatically.

1. **Apply data and inventory updates**

No SQL migration or new inventory item is required. Install every new particle file listed in Changed Files and the complete `source/*` folder, which includes the fire audio and its attribution. Keep existing missions, hydrants, vehicle/hose setup and saved configurator values. Additional languages translate the new effect controls; older text without a translation uses English.

1. **Restart and verify**

Restart the database, framework and any edited inventory first, then Base, Jobs Base and the installed job resources. Confirm `1.12.0` and resolve startup errors before admitting players. Create a small growing fire, select each flame/smoke style and verify ground and wall contact. Check directional sound at different distances, then adjust sound and smoke settings through /jobconfig. Test a large incident with water jets, smoke exposure and extinguishing. Edit and reload a saved mission to confirm its effect choices remain intact. If using a custom Dispatch provider, test both individual fires and missions.

</template>

<template v-slot:prepare="">

Update Base to `1.41.0` and Jobs Base to `1.44.0` before installing `sky_firejob` `1.12.0`. These instructions cover `1.11.0` → `1.12.0`; complete earlier migrations first when upgrading from an older version. Stop the server and back up the resource, database, customized files and saved configurator/creator data.

</template>

<template v-slot:files="">

Install the matching `1.12.0` download. Update every path in **Changed Files**, delete and reinsert `sky_firejob/source/*`, and replace `sky_firejob/config/locales/*` completely. Remove the exact paths under **Removed Files** and apply any listed renames. Preserve unrelated files, writable data and custom assets; merge the configuration changes in this tab into your customized public files.

Replace `source/*` and `fxmanifest.lua` from the same download even when optional diagnostics remain off. Profiler instrumentation is confined to Lua in `source/` and the generated manifest. Public configuration, integration and compatibility files match the uninstrumented source; their functional changes are listed separately for this release. If an older profiler package modified public files, restore those once from the clean new package and reapply your own edits.

</template>

<template v-slot:config="">

Merge these changes into `sky_firejob/config/config.lua`. With `/jobconfig`, use Fire → Settings → Fire system; the exact stored keys are listed below. Saved overrides remain authoritative. Appearance controls do not change smoke-poisoning strength.

<table>
<thead>
  <tr>
    <th>
      File path under <code>
        Config.FireSystem
      </code>
    </th>
    
    <th>
      Previous value
    </th>
    
    <th>
      New value
    </th>
    
    <th>
      <code>
        /jobconfig
      </code>
      
       key
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      <code>
        render.flameScaleMultiplier
      </code>
    </td>
    
    <td>
      Absent
    </td>
    
    <td>
      <code>
        1.0
      </code>
    </td>
    
    <td>
      <code>
        fireFlameScaleMultiplier
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        render.smokeScaleMultiplier
      </code>
    </td>
    
    <td>
      Absent
    </td>
    
    <td>
      <code>
        1.0
      </code>
    </td>
    
    <td>
      <code>
        fireSmokeScaleMultiplier
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        render.smokeDensityMultiplier
      </code>
    </td>
    
    <td>
      Absent
    </td>
    
    <td>
      <code>
        1.0
      </code>
    </td>
    
    <td>
      <code>
        fireSmokeDensityMultiplier
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        render.smokeWindResponse
      </code>
    </td>
    
    <td>
      Absent
    </td>
    
    <td>
      <code>
        "normal"
      </code>
    </td>
    
    <td>
      <code>
        fireSmokeWindResponse
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        ignition.startScale
      </code>
    </td>
    
    <td>
      Absent
    </td>
    
    <td>
      <code>
        0.2
      </code>
    </td>
    
    <td>
      <code>
        fireIgnitionStartScale
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        ignition.growthSeconds
      </code>
    </td>
    
    <td>
      Absent
    </td>
    
    <td>
      <code>
        40.0
      </code>
    </td>
    
    <td>
      <code>
        fireIgnitionGrowthSeconds
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        effects.sounds.fireAmbient.volume
      </code>
    </td>
    
    <td>
      <code>
        1.0
      </code>
    </td>
    
    <td>
      <code>
        0.65
      </code>
    </td>
    
    <td>
      <code>
        fireSoundFireAmbientVolume
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        effects.sounds.fireAmbient.range
      </code>
    </td>
    
    <td>
      <code>
        10.0
      </code>
    </td>
    
    <td>
      <code>
        40.0
      </code>
    </td>
    
    <td>
      <code>
        fireSoundFireAmbientRange
      </code>
    </td>
  </tr>
</tbody>
</table>

The ambient-sound switch remains enabled by default (`fireSoundFireAmbientEnabled`). Wind choices are `none`, `gentle`, `normal` and `strong`; the new choice applies to packaged smoke. Add the new ignition table and render values, and change the two sound values inside their existing parents:

```lua
Config.FireSystem.render.flameScaleMultiplier = 1.0
Config.FireSystem.render.smokeScaleMultiplier = 1.0
Config.FireSystem.render.smokeDensityMultiplier = 1.0
Config.FireSystem.render.smokeWindResponse = "normal"
Config.FireSystem.ignition = {
    startScale = 0.2,
    growthSeconds = 40.0,
}
Config.FireSystem.effects.sounds.fireAmbient.volume = 0.65
Config.FireSystem.effects.sounds.fireAmbient.range = 40.0
```

The shared Fire defaults also add client-wide visual limits of `96` flame sources and `24` smoke sources, exposed as `fireMaxFlameSources` and `fireMaxSmokeSources`. File-based servers may override `Config.FireSystem.render.maxFlameSources` and `Config.FireSystem.render.maxSmokeSources`; otherwise the shared defaults supply them. These limit visible effects, not the number of saved incidents. Flame and smoke visibility distances remain 1000 m in the shipped file; the existing shared visibility setting controls both when `/jobconfig` is used.

The new `sky_firejob/config/sv_functions.lua` supplies the Dispatch hook. Install the complete file. Its default continues to send alerts through Jobs Base, so no external provider is required. Only customize `Config.Functions.sendDispatch` if forwarding alerts to another system; retain the documented success/failure result and handle that provider's alert cleanup. This Lua function remains file-based and is intentionally outside `/jobconfig`.

Choose flame and smoke variants in `/skyfiremenu` or in the mission creator. Existing saved missions keep their choices/default profiles; do not delete or reimport them to obtain the new selectors. Starting size and growth duration affect newly created menu fires. No job list, incident-reward setting or hose-vehicle geometry changes in this release.

**Optional performance diagnostics**

Extra profiler information remains disabled by default. For a support recording, add `setr sky_profiler 1` to `server.cfg` before the Sky `ensure` lines and restart the server. In the server console, run `profiler record 1000`, wait for `profiler status` to report completion, then run `profiler saveJSON sky-release-profile.json`. Share that file when requested by support. Set `setr sky_profiler 0` and restart again to disable the extra information. This is not a `/jobconfig` setting; enabling it does not start a recording or upload data automatically.

</template>

<template v-slot:data="">

No SQL migration or new inventory item is required. Install every new particle file listed in Changed Files and the complete `source/*` folder, which includes the fire audio and its attribution. Keep existing missions, hydrants, vehicle/hose setup and saved configurator values. Additional languages translate the new effect controls; older text without a translation uses English.

</template>

<template v-slot:verify="">

Restart the database, framework and any edited inventory first, then Base, Jobs Base and the installed job resources. Confirm `1.12.0` and resolve startup errors before admitting players. Create a small growing fire, select each flame/smoke style and verify ground and wall contact. Check directional sound at different distances, then adjust sound and smoke settings through /jobconfig. Test a large incident with water jets, smoke exposure and extinguishing. Edit and reload a saved mission to confirm its effect choices remain intact. If using a custom Dispatch provider, test both individual fires and missions.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-09-14" title="Version 1.11.0">
<template v-slot:body="">
<callout color="warning" icon="i-lucide-triangle-alert">

Update Base to `1.40.0` and Jobs Base to `1.43.0` before installing `sky_firejob` `1.11.0`.

</callout>

**Highlights**

- Fixed an issue where moving HUD elements could also move the player or camera.

**Notable Changes**

- Optimized oil-spill contact checks to avoid unnecessary background work while retaining slip behavior.

**Other Changes**

- Updated bundled Fire Job images with smaller files.

**Changed Files**

- `sky_firejob/config/inventory/broom.png`
- `sky_firejob/config/inventory/fire_air_bottle.png`
- `sky_firejob/config/inventory/fire_extinguisher_mount_kit.png`
- `sky_firejob/config/inventory/fire_heli_bucket.png`
- `sky_firejob/config/inventory/fire_protective_mask.png`
- `sky_firejob/config/inventory/foam_canister.png`
- `sky_firejob/config/inventory/glas_hammer.png`
- `sky_firejob/config/inventory/hydraulic_spreader.png`
- `sky_firejob/config/inventory/lighter.png`
- `sky_firejob/config/inventory/oil_absorbent.png`
- `sky_firejob/config/inventory/rescue_cushion.png`
- `sky_firejob/config/inventory/water_monitor.png`
- `sky_firejob/config/locales/*`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/source/*` — delete and reinsert

<update-guide from="1.10.0" resource="sky_firejob" to="1.11.0">
<template v-slot:simplified="">

1. **Prepare the update**

Update Base to `1.40.0` and Jobs Base to `1.43.0` before installing `sky_firejob` `1.11.0`. These instructions cover `1.10.0` → `1.11.0`; complete earlier migrations first when upgrading from an older version. Stop the server and back up the resource, database, customized files and saved configurator/creator data.

1. **Replace the package files**

Install the matching `1.11.0` package. Update every path in **Changed Files**, delete and reinsert `sky_firejob/source/*`, and replace `sky_firejob/config/locales/*` completely. Remove every exact path listed under **Removed Files** and apply any listed renames. Preserve unrelated files, writable data and your own custom assets; merge the configuration changes in this tab into customized public files.

Replace `source/*` and `fxmanifest.lua` from the same download even when optional diagnostics remain off. The profiler only instruments Lua inside `source/` and adds its manifest entries; public configuration, integration and compatibility files must match the uninstrumented package. Apply the separate functional public-file changes listed for this release. If an older profiler package modified public files, restore those once from the clean new package and reapply your edits.

1. **Merge configuration**

No public configuration values, blocks, items or Fire-specific database schema change. Keep existing `/jobconfig` overrides, mission settings, oil-spill behavior and HUD preferences. The HUD editor input correction and oil checks require the matching new runtime and UI files, not new settings.

**Optional performance diagnostics**

Extra profiler information remains disabled by default. Normal use needs no diagnostic setting. For a support recording, add `setr sky_profiler 1` to `server.cfg` before the Sky `ensure` lines and restart the server. In the server console, run `profiler record 1000`, wait for `profiler status` to report completion, then run `profiler saveJSON sky-release-profile.json`. Share that file only when requested by support. Set `setr sky_profiler 0` and restart again to disable the extra information. This is not a `/jobconfig` option; enabling it does not start a recording or upload data automatically.

1. **Apply data and inventory updates**

No Fire-specific migration or new items are required. Preserve mission and creator data. Complete any shared Jobs Base `1.43.0` database migrations as part of the dependency update; they do not require clearing Fire data.

1. **Restart and verify**

Confirm version `1.11.0`. Open the HUD editor, drag and save an element, then close it and confirm normal player/camera controls return. Test an oil spill with a nearby player, including entering its area quickly and returning after revival. Check images, saved missions and startup logs.

</template>

<template v-slot:prepare="">

Update Base to `1.40.0` and Jobs Base to `1.43.0` before installing `sky_firejob` `1.11.0`. These instructions cover `1.10.0` → `1.11.0`; complete earlier migrations first when upgrading from an older version. Stop the server and back up the resource, database, customized files and saved configurator/creator data.

</template>

<template v-slot:files="">

Install the matching `1.11.0` package. Update every path in **Changed Files**, delete and reinsert `sky_firejob/source/*`, and replace `sky_firejob/config/locales/*` completely. Remove every exact path listed under **Removed Files** and apply any listed renames. Preserve unrelated files, writable data and your own custom assets; merge the configuration changes in this tab into customized public files.

Replace `source/*` and `fxmanifest.lua` from the same download even when optional diagnostics remain off. The profiler only instruments Lua inside `source/` and adds its manifest entries; public configuration, integration and compatibility files must match the uninstrumented package. Apply the separate functional public-file changes listed for this release. If an older profiler package modified public files, restore those once from the clean new package and reapply your edits.

</template>

<template v-slot:config="">

No public configuration values, blocks, items or Fire-specific database schema change. Keep existing `/jobconfig` overrides, mission settings, oil-spill behavior and HUD preferences. The HUD editor input correction and oil checks require the matching new runtime and UI files, not new settings.

**Optional performance diagnostics**

Extra profiler information remains disabled by default. Normal use needs no diagnostic setting. For a support recording, add `setr sky_profiler 1` to `server.cfg` before the Sky `ensure` lines and restart the server. In the server console, run `profiler record 1000`, wait for `profiler status` to report completion, then run `profiler saveJSON sky-release-profile.json`. Share that file only when requested by support. Set `setr sky_profiler 0` and restart again to disable the extra information. This is not a `/jobconfig` option; enabling it does not start a recording or upload data automatically.

</template>

<template v-slot:data="">

No Fire-specific migration or new items are required. Preserve mission and creator data. Complete any shared Jobs Base `1.43.0` database migrations as part of the dependency update; they do not require clearing Fire data.

</template>

<template v-slot:verify="">

Confirm version `1.11.0`. Open the HUD editor, drag and save an element, then close it and confirm normal player/camera controls return. Test an oil spill with a nearby player, including entering its area quickly and returning after revival. Check images, saved missions and startup logs.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-09-12" title="Version 1.10.0">
<template v-slot:body="">
<callout color="warning" icon="i-lucide-triangle-alert">

Update **sky_base** to `1.39.0` and **sky_jobs_base** to `1.42.0` before installing **sky_firejob** `1.10.0`.

</callout>

**Highlights**

- Added a clear warning when a mission starts successfully but its emergency dispatch cannot be created, including steps to correct the problem.

**Notable Changes**

- Improved mission feedback so a running mission stays visible and controllable when its dispatch fails.
- Improved error messages with translated explanations and readable multi-line instructions.

**Other Changes**

- Removed the duplicate console error for a failed mission dispatch so the detailed Jobs Base explanation is easier to find.
- Added optional performance diagnostics to help support investigate lag and delays, with diagnostics disabled by default.

**Changed Files**

- `sky_firejob/config/locales/*`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/source/*` — delete and reinsert

<update-guide from="1.9.1" resource="sky_firejob" to="1.10.0">
<template v-slot:simplified="">

1. Prepare the update.

Update **sky_base** to `1.39.0` and **sky_jobs_base** to `1.42.0` before installing **sky_firejob** `1.10.0`. These steps cover `1.9.1` → `1.10.0`. Follow earlier update instructions first when upgrading from an older version. Stop the server and back up the resource, database, custom settings, and saved configurator data.

1. Replace the package files.

Install the matching `1.10.0` package. Update every path listed in **Changed Files**, delete and reinsert `sky_firejob/source/*`, and replace `sky_firejob/config/locales/*` completely. Merge the configuration changes in this tab into your customized files. Preserve writable data and generated user content.

**Required profiler files**

For the profiler update, replace the complete `sky_firejob/source/*` tree and `sky_firejob/fxmanifest.lua` from the same download, even if diagnostics stay disabled. Delete the old `source/` folder before copying the new one.

The profiler builder leaves configuration, integration and compatibility files unchanged. Apply any separate configuration or integration changes listed for this release as usual.

If you previously installed an older profiler package that also modified files outside `source/`, restore those affected files once from the unmodified versions in the new download and reapply your custom edits. Later profiler-only updates do not require this step.

1. Merge and review configuration.

No values or blocks in `sky_firejob/config/config.lua` change in this release. Keep your custom configuration and saved `/jobconfig` settings. Replace all Fire locales and update Jobs Base to `1.42.0` for the matching dispatch explanations.

If a mission starts with a dispatch warning, it is already running. Use its active mission controls to manage or stop it. Follow the displayed instructions: open `/missioncreator`, select the named mission, and check its receiving department and response plan. Review the plan under that department in `/jobconfig`; dispatch-center coverage is maintained in `sky_jobs_base/config/config.lua`. Resolve the cause before starting another copy of the mission.

**Optional performance diagnostics**

Sky's extra profiler information is disabled by default. This update does not start recordings or send data automatically. No configuration change is required for normal use. If support needs a performance recording, add the following line to `server.cfg` before the Sky `ensure` lines, then restart the server:

```cfg [server.cfg]
setr sky_profiler 1
```

This global setting is configured in `server.cfg`; it is not managed by `/jobconfig`. The previous state with no setting remains disabled. Set the value to `1` only when you want the additional diagnostics.

Run `profiler record 1000` in the server console for a server delay, or in the player's F8 console for a client problem. Reproduce the issue during the recording. Wait until `profiler status` reports that recording has stopped, then run `profiler saveJSON sky-profile.json` in the same console to save the capture. These are the [standard FiveM profiler commands](https://docs.fivem.net/docs/scripting-manual/debugging/using-profiler/).

After diagnostics, change the line to `setr sky_profiler 0` and restart again. Keep the new package files installed; disabling diagnostics does not require editing Lua or removing manifest entries.

1. Apply database and item changes.

No SQL schema, inventory item, image, or provider-secret change is introduced. Keep saved mission definitions, active operational data, and department settings. Replace all Fire locales so the new guidance is available in your selected language.

1. Start and verify the update.

Start a correctly configured mission and check its dispatch. In staging, use a mission with an invalid response-plan selection to verify that the mission remains manageable and the warning names the cause and repair steps. Correct the selection and confirm the next dispatch can be created.

</template>

<template v-slot:prepare="">

Update **sky_base** to `1.39.0` and **sky_jobs_base** to `1.42.0` before installing **sky_firejob** `1.10.0`. These steps cover `1.9.1` → `1.10.0`. Follow earlier update instructions first when upgrading from an older version. Stop the server and back up the resource, database, custom settings, and saved configurator data.

</template>

<template v-slot:files="">

Install the matching `1.10.0` package. Update every path listed in **Changed Files**, delete and reinsert `sky_firejob/source/*`, and replace `sky_firejob/config/locales/*` completely. Merge the configuration changes in this tab into your customized files. Preserve writable data and generated user content.

**Required profiler files**

For the profiler update, replace the complete `sky_firejob/source/*` tree and `sky_firejob/fxmanifest.lua` from the same download, even if diagnostics stay disabled. Delete the old `source/` folder before copying the new one.

The profiler builder leaves configuration, integration and compatibility files unchanged. Apply any separate configuration or integration changes listed for this release as usual.

If you previously installed an older profiler package that also modified files outside `source/`, restore those affected files once from the unmodified versions in the new download and reapply your custom edits. Later profiler-only updates do not require this step.

</template>

<template v-slot:config="">

No values or blocks in `sky_firejob/config/config.lua` change in this release. Keep your custom configuration and saved `/jobconfig` settings. Replace all Fire locales and update Jobs Base to `1.42.0` for the matching dispatch explanations.

If a mission starts with a dispatch warning, it is already running. Use its active mission controls to manage or stop it. Follow the displayed instructions: open `/missioncreator`, select the named mission, and check its receiving department and response plan. Review the plan under that department in `/jobconfig`; dispatch-center coverage is maintained in `sky_jobs_base/config/config.lua`. Resolve the cause before starting another copy of the mission.

**Optional performance diagnostics**

Sky's extra profiler information is disabled by default. This update does not start recordings or send data automatically. No configuration change is required for normal use. If support needs a performance recording, add the following line to `server.cfg` before the Sky `ensure` lines, then restart the server:

```cfg [server.cfg]
setr sky_profiler 1
```

This global setting is configured in `server.cfg`; it is not managed by `/jobconfig`. The previous state with no setting remains disabled. Set the value to `1` only when you want the additional diagnostics.

Run `profiler record 1000` in the server console for a server delay, or in the player's F8 console for a client problem. Reproduce the issue during the recording. Wait until `profiler status` reports that recording has stopped, then run `profiler saveJSON sky-profile.json` in the same console to save the capture. These are the [standard FiveM profiler commands](https://docs.fivem.net/docs/scripting-manual/debugging/using-profiler/).

After diagnostics, change the line to `setr sky_profiler 0` and restart again. Keep the new package files installed; disabling diagnostics does not require editing Lua or removing manifest entries.

</template>

<template v-slot:data="">

No SQL schema, inventory item, image, or provider-secret change is introduced. Keep saved mission definitions, active operational data, and department settings. Replace all Fire locales so the new guidance is available in your selected language.

</template>

<template v-slot:verify="">

Start a correctly configured mission and check its dispatch. In staging, use a mission with an invalid response-plan selection to verify that the mission remains manageable and the warning names the cause and repair steps. Correct the selection and confirm the next dispatch can be created.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-09-09" title="Version 1.9.1">
<template v-slot:body="">
<callout color="warning" icon="i-lucide-triangle-alert">

Update **sky_jobs_base** to `1.41.1` and use **sky_base** `1.38.0` before updating **sky_firejob**.

</callout>

**Highlights**

- Fixed an issue where automatic missions kept an outdated waiting interval after their settings changed.

**Notable Changes**

- Fixed an issue where Fire could overwrite the off-duty settings of a job shared with another service.
- Improved scenario alerts so response plans use the configured responsible job.

**Other Changes**

- Updated scenario status labels to distinguish scenarios available in the hub from local scenarios.

**Changed Files**

- `sky_firejob/config/locales/*`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/source/*` — delete and reinsert

<update-guide from="1.9.0" resource="sky_firejob" to="1.9.1">
<template v-slot:simplified="">

1. Update **sky_jobs_base** to `1.41.1` and use **sky_base** `1.38.0` before updating **sky_firejob**. These steps cover `1.9.0` → `1.9.1`; complete earlier release instructions first if you are upgrading from an older version. Stop the server and back up the resource, database, saved Job Configurator settings and custom configuration. Preserve generated reports and other writable data.
2. Install `1.9.1` as a matching package. Update every path in **Changed Files**, delete and reinsert `sky_firejob/source/*`, and replace `sky_firejob/config/locales/*` completely. Merge the configuration instructions in this tab into customized files; retain intentional settings and persistent data.
3. Review the configuration steps.

No public `config.lua` value or new `/jobconfig` setting is introduced in this patch. Keep your saved automatic-mission enablement, interval and chance values. Changes to the interval now reschedule the pending check, disabling automatic missions cancels it, and the current chance is used when a check becomes due.

For a job shared with Ambulance or another service, update Jobs Base to `1.41.1` and review `Config.PrimaryJobGroups` in `sky_jobs_base/config/config.lua` using its own update guide. This global Jobs Base setting selects the shared duty and organization owner; it is not a Fire `/jobconfig` setting. Keep each service's existing station catalogs, and check the chosen owner's Dispatch configuration and each scenario's responsible job and response-plan selection.

1. Apply the data, inventory and asset steps.

Replace all `sky_firejob/config/locales/*` for the clearer hub/local status labels. No SQL schema, inventory item, image, stream asset or provider secret change is required. Preserve scenarios, incidents, equipment data and saved configuration.

1. Start providers, Base, Jobs Base and Fire in that order. Change an automatic-mission interval, disable and re-enable the scheduler, verify the selected scenario response plan and check shared-job duty behavior. Confirm the hub/local labels in the scenario manager.

</template>

<template v-slot:prepare="">

Update **sky_jobs_base** to `1.41.1` and use **sky_base** `1.38.0` before updating **sky_firejob**. These steps cover `1.9.0` → `1.9.1`; complete earlier release instructions first if you are upgrading from an older version. Stop the server and back up the resource, database, saved Job Configurator settings and custom configuration. Preserve generated reports and other writable data.

</template>

<template v-slot:files="">

Install `1.9.1` as a matching package. Update every path in **Changed Files**, delete and reinsert `sky_firejob/source/*`, and replace `sky_firejob/config/locales/*` completely. Merge the configuration instructions in this tab into customized files; retain intentional settings and persistent data.

</template>

<template v-slot:config="">

No public `config.lua` value or new `/jobconfig` setting is introduced in this patch. Keep your saved automatic-mission enablement, interval and chance values. Changes to the interval now reschedule the pending check, disabling automatic missions cancels it, and the current chance is used when a check becomes due.

For a job shared with Ambulance or another service, update Jobs Base to `1.41.1` and review `Config.PrimaryJobGroups` in `sky_jobs_base/config/config.lua` using its own update guide. This global Jobs Base setting selects the shared duty and organization owner; it is not a Fire `/jobconfig` setting. Keep each service's existing station catalogs, and check the chosen owner's Dispatch configuration and each scenario's responsible job and response-plan selection.

</template>

<template v-slot:data="">

Replace all `sky_firejob/config/locales/*` for the clearer hub/local status labels. No SQL schema, inventory item, image, stream asset or provider secret change is required. Preserve scenarios, incidents, equipment data and saved configuration.

</template>

<template v-slot:verify="">

Start providers, Base, Jobs Base and Fire in that order. Change an automatic-mission interval, disable and re-enable the scheduler, verify the selected scenario response plan and check shared-job duty behavior. Confirm the hub/local labels in the scenario manager.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-09-08" title="Version 1.9.0">
<template v-slot:body="">
<callout color="warning" icon="i-lucide-triangle-alert">

Update **sky_base** to `1.38.0` and **sky_jobs_base** to `1.41.0` before updating **sky_firejob**.

</callout>

**Highlights**

- Added player-configurable fire, editor, helicopter-bucket, deck-gun, and vehicle-HUD key bindings, including separate mouse and controller controls.
- Fixed an issue where hydrant supply hoses were missing for other players or players joining later.
- Changed pump-related vehicle engine damage to be disabled by default and explicitly enabled by the server operator.

**Notable Changes**

- Fixed an issue where delayed fire, scenario, and equipment updates could restore removed objects or replace newer state.
- Fixed an issue where vehicle air-cylinder storage was blocked when refill stations were disabled.
- Fixed an issue where the configured foam canister could not be used from the inventory to refill equipment.

**Other Changes**

- Fixed an issue where pressing Escape in an open shared dropdown could also close its surrounding dialog.
- Improved foam-refill cancellation and item validation after a live configuration change.
- Improved separation of shipped Fire defaults and imported customer settings.
- Updated translations for air-cylinder storage requirements and the optional pump-damage setting.

**Changed Files**

- `sky_firejob/config/config.lua`
- `sky_firejob/config/locales/*`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/source/*` — delete and reinsert

<update-guide from="1.8.0" resource="sky_firejob" to="1.9.0">
<template v-slot:simplified="">

1. Update **sky_base** to `1.38.0` and **sky_jobs_base** to `1.41.0` before updating **sky_firejob**. Stop the server and back up the complete `sky_firejob` resource, its database and inventory data, saved Job Configurator settings where applicable, and intentional public configuration edits. Preserve writable reports and other generated data outside the replaceable source files.
2. Install `1.9.0` as a consistent package. Replace every file listed in **Changed Files**, delete and reinsert `sky_firejob/source/*`, and replace `sky_firejob/config/locales/*` completely. Merge the public configuration changes listed in this tab into your customized files; do not copy old configuration files over the new package wholesale. Keep the manifest, built UI, runtime and dependencies from the matching release set.
3. Apply the following configuration changes before starting the resource.

In `sky_firejob/config/config.lua`, add the complete `Config.Keybinds` block. This table and its paths were absent in `1.8.0`; `1.9.0` uses the following string defaults instead of scattered settings or fixed controls. Preserve your chosen keys when transferring old settings.

```lua [config/config.lua]
Config.Keybinds = {
    fireInteriorExtinguishersControl38 = "E",
    fireEditorControl174 = "LEFT",
    fireEditorControl175 = "RIGHT",
    fireEditorControl14 = "MOUSE_WHEEL:IOM_WHEEL_DOWN",
    fireEditorControl15 = "MOUSE_WHEEL:IOM_WHEEL_UP",
    fireEditorControl177 = "BACK",
    fireWaterMonitorControl172 = "UP",
    fireWaterMonitorControl241 = "MOUSE_WHEEL:IOM_WHEEL_UP",
    fireWaterMonitorControl173 = "DOWN",
    fireWaterMonitorControl242 = "MOUSE_WHEEL:IOM_WHEEL_DOWN",
    fireWaterMonitorControl174 = "LEFT",
    fireWaterMonitorControl175 = "RIGHT",
    fireWaterMonitorControl24 = "MOUSE_BUTTON:MOUSE_LEFT",
    fireWaterMonitorControl25 = "MOUSE_BUTTON:MOUSE_RIGHT",
    fireWaterMonitorControl177 = "BACK",
    fireWaterMonitorControl202 = "ESCAPE",
    fireEditorControl24 = "MOUSE_BUTTON:MOUSE_LEFT",
    fireEditorControl199 = "P",
    fireEditorControl200 = "ESCAPE",
    fireEditorControl202 = "ESCAPE",
    fireEditorControl322 = "ESCAPE",
    firePropIgnitionControl177 = "BACK",
    firePropIgnitionControl38 = "E",
    fireEditorControl25 = "MOUSE_BUTTON:MOUSE_RIGHT",
    fireEditorControl21 = "LSHIFT",
    fireEditorControl36 = "LCONTROL",
    fireEditorControl32 = "W",
    fireEditorControl33 = "S",
    fireEditorControl34 = "A",
    fireEditorControl35 = "D",
    fireEditorControl44 = "Q",
    fireEditorControl38 = "E",
    fireEditorControl45 = "R",
    fireEditorControl191 = "RETURN",
    heliBucketAttachKey = "E",
    heliBucketDumpKey = "X",
    deckGunSprayGamepadKey = "PAD_ANALOGBUTTON:L1_INDEX",
    deckGunSprayKey = "MOUSE_BUTTON:MOUSE_RIGHT",
    firetruckHudToggleKey = "",
    firetruckHudCursorKey = "LCONTROL",
}
```

With `Config.UseJobConfigurator = true`, open `/jobconfig` → this resource → **General → Keybinds**. Every key inside the block is also its exact saved setting ID; for example `Config.Keybinds.fireInteriorExtinguishersControl38` is saved under the same final name. Saved overrides take precedence over the generated defaults. Numeric overrides migrate to their corresponding QWERTY key, and `-1` migrates to an empty string. An empty string means no initial binding. Players retain their own assignments in **Settings → Key Bindings → FiveM**; changing a server default does not overwrite those assignments.

With `Config.UseJobConfigurator = false`, edit these paths in the file and restart the resource. Keep mouse/controller prefixes exactly as shown. Command permissions and `Config.AutoExecuteQuery` remain file settings; their reordering does not change their values.

Add the new `Config.Hose.vehiclePumpBehavior.engineDamageEnabled` path in `sky_firejob/config/config.lua`:

<table>
<thead>
  <tr>
    <th>
      Path
    </th>
    
    <th>
      <code>
        1.8.0
      </code>
    </th>
    
    <th>
      <code>
        1.9.0
      </code>
    </th>
    
    <th>
      Saved <code>
        /jobconfig
      </code>
      
       key
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      <code>
        Config.Hose.vehiclePumpBehavior.engineDamageEnabled
      </code>
    </td>
    
    <td>
      absent; pump stress could damage the engine
    </td>
    
    <td>
      <code>
        false
      </code>
    </td>
    
    <td>
      <code>
        hoseVehiclePumpBehaviorEngineDamageEnabled
      </code>
    </td>
  </tr>
</tbody>
</table>

```lua [config/config.lua]
Config.Hose.vehiclePumpBehavior.engineDamageEnabled = false
```

With `/jobconfig`, review the saved **Hose → Vehicle pump behavior → Engine damage** setting. Saved overrides take precedence over the default; explicitly enable it only if pump overheating and dry running should damage the vehicle. Without `/jobconfig`, maintain the file value. Existing neighboring values remain `warningTemperature = 100.0`, `criticalTemperature = 115.0`, `damageTemperature = 110.0`, and `maxEngineDamagePerSecond = 12.0`; temperature warnings and pump behavior still operate when engine damage is disabled. No incident job list, reward, hose model offset, or dispatch-recipient value changes in this release.

Air-cylinder storage still requires its configured bottle item and pressure saving. The refill-station feature itself may now be disabled. Keep your existing cylinder item, pressure-saving and foam-canister settings, and check their effective saved `/jobconfig` overrides. Foam inventory use now follows the same existing refill validation and cancellation flow. No replacement item name or new refill setting is required. `Config.UseJobConfigurator`, command permissions and `Config.AutoExecuteQuery` were only moved to the top of the file; their defaults are unchanged.

1. Complete the following database, inventory, and asset steps.

No new Fire SQL schema, inventory item, image, production stream asset, or secret is introduced. Preserve existing cylinders and pressure metadata, configured foam items, incidents and equipment data. Replace the manifest and full source folder together; the updated manifest loads the generated Fire defaults and shared key/synchronization helpers. Install Base 1.38.0 too for the Jaksam slot correction when using that inventory.

1. Restart Base, Jobs Base and Fire. Rebind helicopter, editor, HUD and deck-gun actions and test both mouse and controller spraying. Join after a hydrant supply hose is connected and confirm both nearby players see it. Remove equipment during synchronization and confirm it stays removed. With pressure saving and the bottle item enabled, open air storage while refill stations are disabled. Use and cancel a foam refill. Test pump overheating/dry running with engine damage disabled, then explicitly enabled, and check the effective saved setting.

</template>

<template v-slot:prepare="">

Update **sky_base** to `1.38.0` and **sky_jobs_base** to `1.41.0` before updating **sky_firejob**. Stop the server and back up the complete `sky_firejob` resource, its database and inventory data, saved Job Configurator settings where applicable, and intentional public configuration edits. Preserve writable reports and other generated data outside the replaceable source files.

</template>

<template v-slot:files="">

Install `1.9.0` as a consistent package. Replace every file listed in **Changed Files**, delete and reinsert `sky_firejob/source/*`, and replace `sky_firejob/config/locales/*` completely. Merge the public configuration changes listed in this tab into your customized files; do not copy old configuration files over the new package wholesale. Keep the manifest, built UI, runtime and dependencies from the matching release set.

</template>

<template v-slot:config="">

In `sky_firejob/config/config.lua`, add the complete `Config.Keybinds` block. This table and its paths were absent in `1.8.0`; `1.9.0` uses the following string defaults instead of scattered settings or fixed controls. Preserve your chosen keys when transferring old settings.

```lua [config/config.lua]
Config.Keybinds = {
    fireInteriorExtinguishersControl38 = "E",
    fireEditorControl174 = "LEFT",
    fireEditorControl175 = "RIGHT",
    fireEditorControl14 = "MOUSE_WHEEL:IOM_WHEEL_DOWN",
    fireEditorControl15 = "MOUSE_WHEEL:IOM_WHEEL_UP",
    fireEditorControl177 = "BACK",
    fireWaterMonitorControl172 = "UP",
    fireWaterMonitorControl241 = "MOUSE_WHEEL:IOM_WHEEL_UP",
    fireWaterMonitorControl173 = "DOWN",
    fireWaterMonitorControl242 = "MOUSE_WHEEL:IOM_WHEEL_DOWN",
    fireWaterMonitorControl174 = "LEFT",
    fireWaterMonitorControl175 = "RIGHT",
    fireWaterMonitorControl24 = "MOUSE_BUTTON:MOUSE_LEFT",
    fireWaterMonitorControl25 = "MOUSE_BUTTON:MOUSE_RIGHT",
    fireWaterMonitorControl177 = "BACK",
    fireWaterMonitorControl202 = "ESCAPE",
    fireEditorControl24 = "MOUSE_BUTTON:MOUSE_LEFT",
    fireEditorControl199 = "P",
    fireEditorControl200 = "ESCAPE",
    fireEditorControl202 = "ESCAPE",
    fireEditorControl322 = "ESCAPE",
    firePropIgnitionControl177 = "BACK",
    firePropIgnitionControl38 = "E",
    fireEditorControl25 = "MOUSE_BUTTON:MOUSE_RIGHT",
    fireEditorControl21 = "LSHIFT",
    fireEditorControl36 = "LCONTROL",
    fireEditorControl32 = "W",
    fireEditorControl33 = "S",
    fireEditorControl34 = "A",
    fireEditorControl35 = "D",
    fireEditorControl44 = "Q",
    fireEditorControl38 = "E",
    fireEditorControl45 = "R",
    fireEditorControl191 = "RETURN",
    heliBucketAttachKey = "E",
    heliBucketDumpKey = "X",
    deckGunSprayGamepadKey = "PAD_ANALOGBUTTON:L1_INDEX",
    deckGunSprayKey = "MOUSE_BUTTON:MOUSE_RIGHT",
    firetruckHudToggleKey = "",
    firetruckHudCursorKey = "LCONTROL",
}
```

With `Config.UseJobConfigurator = true`, open `/jobconfig` → this resource → **General → Keybinds**. Every key inside the block is also its exact saved setting ID; for example `Config.Keybinds.fireInteriorExtinguishersControl38` is saved under the same final name. Saved overrides take precedence over the generated defaults. Numeric overrides migrate to their corresponding QWERTY key, and `-1` migrates to an empty string. An empty string means no initial binding. Players retain their own assignments in **Settings → Key Bindings → FiveM**; changing a server default does not overwrite those assignments.

With `Config.UseJobConfigurator = false`, edit these paths in the file and restart the resource. Keep mouse/controller prefixes exactly as shown. Command permissions and `Config.AutoExecuteQuery` remain file settings; their reordering does not change their values.

Add the new `Config.Hose.vehiclePumpBehavior.engineDamageEnabled` path in `sky_firejob/config/config.lua`:

<table>
<thead>
  <tr>
    <th>
      Path
    </th>
    
    <th>
      <code>
        1.8.0
      </code>
    </th>
    
    <th>
      <code>
        1.9.0
      </code>
    </th>
    
    <th>
      Saved <code>
        /jobconfig
      </code>
      
       key
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      <code>
        Config.Hose.vehiclePumpBehavior.engineDamageEnabled
      </code>
    </td>
    
    <td>
      absent; pump stress could damage the engine
    </td>
    
    <td>
      <code>
        false
      </code>
    </td>
    
    <td>
      <code>
        hoseVehiclePumpBehaviorEngineDamageEnabled
      </code>
    </td>
  </tr>
</tbody>
</table>

```lua [config/config.lua]
Config.Hose.vehiclePumpBehavior.engineDamageEnabled = false
```

With `/jobconfig`, review the saved **Hose → Vehicle pump behavior → Engine damage** setting. Saved overrides take precedence over the default; explicitly enable it only if pump overheating and dry running should damage the vehicle. Without `/jobconfig`, maintain the file value. Existing neighboring values remain `warningTemperature = 100.0`, `criticalTemperature = 115.0`, `damageTemperature = 110.0`, and `maxEngineDamagePerSecond = 12.0`; temperature warnings and pump behavior still operate when engine damage is disabled. No incident job list, reward, hose model offset, or dispatch-recipient value changes in this release.

Air-cylinder storage still requires its configured bottle item and pressure saving. The refill-station feature itself may now be disabled. Keep your existing cylinder item, pressure-saving and foam-canister settings, and check their effective saved `/jobconfig` overrides. Foam inventory use now follows the same existing refill validation and cancellation flow. No replacement item name or new refill setting is required. `Config.UseJobConfigurator`, command permissions and `Config.AutoExecuteQuery` were only moved to the top of the file; their defaults are unchanged.

</template>

<template v-slot:data="">

No new Fire SQL schema, inventory item, image, production stream asset, or secret is introduced. Preserve existing cylinders and pressure metadata, configured foam items, incidents and equipment data. Replace the manifest and full source folder together; the updated manifest loads the generated Fire defaults and shared key/synchronization helpers. Install Base 1.38.0 too for the Jaksam slot correction when using that inventory.

</template>

<template v-slot:verify="">

Restart Base, Jobs Base and Fire. Rebind helicopter, editor, HUD and deck-gun actions and test both mouse and controller spraying. Join after a hydrant supply hose is connected and confirm both nearby players see it. Remove equipment during synchronization and confirm it stays removed. With pressure saving and the bottle item enabled, open air storage while refill stations are disabled. Use and cancel a foam refill. Test pump overheating/dry running with engine damage disabled, then explicitly enabled, and check the effective saved setting.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-09-02" title="Version 1.8.0">
<template v-slot:body="">
<callout color="warning" icon="i-lucide-triangle-alert">

Update **sky_base** to `1.37.0` and **sky_jobs_base** to `1.40.0` before updating **sky_firejob**.

</callout>

**Highlights**

- Added a validated server export for creating regular synchronized fires from trusted resources.
- Improved pump operations with configured panel, intake, and outlet positions plus synchronized nozzle, deck-gun, decal, and water-monitor effects.
- Added per-mission `dispatchJobs` routing with fallback to the global Fire dispatch list and then all configured Fire jobs.
- Improved SCBA inventory handling so exact slots persist and usable-item registrations refresh after configuration changes.

**Notable Changes**

- Improved hydrant supply so the selected pump vehicle is used, carried hose state is preserved when detection briefly misses, and server validation completes before connection.
- Improved external LB Tablet and RoadPad lifecycle handling and fixed scrolling in longer Fire reports.
- Fixed the pump-panel interface so NUI focus is released reliably.
- Improved automatic tree incidents so their synchronized state remains stable.
- Improved creator refresh behavior so a saved configuration cannot trigger recursive refreshes.

**Other Changes**

- Changed staffing requirements so configured minimum on-duty counts also apply to prop ignition.
- Removed continuous idle vehicle polling from synchronized water-effect handling.
- Updated number inputs so browser spinner controls match the tablet interface.
- Updated bundled locales for pump operations, supply validation, mission dispatch, SCBA, external tablets, and synchronized effects.

**Changed Files**

- `sky_firejob/README.md`
- `sky_firejob/config/config.lua`
- `sky_firejob/config/locales/*`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/source/*` — delete and reinsert

<update-guide from="1.7.0" resource="sky_firejob" to="1.8.0">
<template v-slot:simplified="">

1. Install **sky_base** `1.37.0` and **sky_jobs_base** `1.40.0`, stop the server, and back up the complete Fire resource, Job Configurator data, Fire records, and intentional configuration edits.
2. Delete the old folder and install the complete `1.8.0` package. Do not mix `1.7.0` manifest, config, locales, UI, README, or `source` files with this release.
3. Review every saved Fire mission's new `dispatchJobs` list. When it is empty, the mission uses `Config.FireScenarioCreator.dispatch.jobs`; when that list is also empty, all configured Fire jobs receive the dispatch.
4. Existing Job Configurator missions are migrated by initializing `dispatchJobs` from their existing `jobs` value. Verify the intended recipients after startup, especially for multi-department servers.
5. No SQL, inventory item, image, or stream asset migration is required.
6. Restart Base, Jobs Base, and Fire in order. Verify prop staffing, exported synchronized fires, pump positions/effects, hydrant supply, mission routing, SCBA slots, tablet lifecycle, reports, NUI focus, tree incidents, and creator refresh.

</template>

<template v-slot:prepare="">

Install Base `1.37.0` and Jobs Base `1.40.0`, stop the server, and back up the complete resource, Job Configurator tables, configured Fire missions, Fire report data, and deliberate edits to pump, scenario, dispatch, SCBA, and external-tablet settings.

> Install `1.8.0` as one clean package. Its manifest, frontend, locales, shared effects, and source files must match.

</template>

<template v-slot:files="">

Delete and reinsert the complete resource. At minimum replace `fxmanifest.lua`, `README.md`, `config/config.lua`, the complete `config/locales` and `source` directories, and the built frontend.

</template>

<template v-slot:config="">

Mission entries below `Config.FireScenarioCreator.randomTrigger.missions` now support `dispatchJobs` in addition to `key`, `enabled`, `minOnDuty`, and `jobs`:

```lua [config/config.lua]
missions = {
    {
        key = "example_mission",
        enabled = true,
        minOnDuty = 0,
        jobs = { "fire" },
        dispatchJobs = { "fire" }
    }
}
```

Dispatch recipients resolve in this order:

1. A non-empty mission `dispatchJobs` list.
2. The global `Config.FireScenarioCreator.dispatch.jobs` list.
3. Every configured Fire job when both lists are empty.

The global dispatch list and other shipped defaults do not change. Job Configurator migration initializes existing mission `dispatchJobs` from each mission's current `jobs` value. Review every saved mission after the update; an explicitly empty list intentionally activates the fallback chain.

</template>

<template v-slot:data="">

No Fire SQL schema change, new inventory item, image, or production stream asset is required. Existing Fire reports, scenarios, SCBA data, and equipment configuration are reused. The new regular-fire export is a trusted server integration and requires no database row or client event exposure.

</template>

<template v-slot:verify="">

Start Base, Jobs Base, and Fire in order. Confirm an under-staffed player cannot ignite a configured prop fire and an adequately staffed player can. From a trusted server resource, call the regular-fire export with valid and invalid data and verify validation plus synchronization. Test pump controls at configured panel/intake/outlet offsets, nozzle/deck-gun/decal/water-monitor visibility across clients, and low idle cost without an active operation. Connect a hydrant to the selected pump while briefly leaving detection range. Verify mission-specific, global, and all-Fire-job dispatch fallbacks; exact-slot SCBA restore after a config refresh; LB Tablet/RoadPad reloads; long-report scrolling; pump-panel focus release; automatic tree incidents; and a single creator refresh after saving.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-08-22" title="Version 1.7.0">
<template v-slot:body="">
<callout color="warning" icon="i-lucide-triangle-alert">

Update **sky_base** to `1.36.0` and **sky_jobs_base** to `1.39.0` before updating **sky_firejob**.

</callout>

**Highlights**

- Added persistent Fire incident reports with an owning job, configurable report catalogues, evidence, involved people, hazards, actions, equipment, and current-scene location capture.
- Added cross-job Fire report sharing so selected partner departments receive read-only access while the owning department retains edit control.
- Improved the report editor with compact adjustable sections, searchable configured fields, localized labels, and clear source-job context for shared reports.

**Notable Changes**

- Improved mission creation so current form values and transforms save automatically and vehicle fires keep their configured scale when progression is disabled.
- Improved rescue repairs so synchronized glass and doors reset correctly, doorless vehicles can be accessed directly, and rear-seat victims in two-door vehicles use a front-door fallback.
- Improved SCBA storage so putting away an equipped bottle saves a bounded remaining pressure value, clears active server state, and follows the normal unequip/HUD flow.
- Improved water-monitor and helicopter-bucket placement with one-time server authorization before a client may create the configured prop.
- Fixed an issue where players without the required Fire access could see the placeable-extinguisher pickup action.

**Other Changes**

- Improved startup migration and direct shared-service usage so report, rescue, prop, and equipment state initializes in the intended order.
- Improved shared tablet controls and theme behavior while removing browser filter effects that could render inconsistently in FiveM CEF.
- Updated English, German, Italian, and Serbian report, rescue, mission, SCBA, and sharing translations.

**Changed Files**

- `sky_firejob/config/config.lua`
- `sky_firejob/config/locales/*`
- `sky_firejob/import.sql`
- `sky_firejob/source/*` — delete and reinsert

<update-guide from="1.6.1" resource="sky_firejob" to="1.7.0">
<template v-slot:simplified="">

1. Install **sky_base** `1.36.0` and **sky_jobs_base** `1.39.0`, stop the server, and back up the complete Fire resource, Job Configurator tables, and all `sky_fire_*` tables.
2. Delete the old folder and install the complete `1.7.0` package. Do not mix the old built UI, locales, schema, or `source` files with this release.
3. Add this complete new plaintext report catalogue. `Config.Reports` was absent in `1.6.1` and `/jobconfig` does not manage these lists:```lua [config/config.lua]
Config.Reports = {
    types = {
        "Structure Fire", "Vehicle Fire", "Wildfire", "Hazmat", "Rescue", "Alarm", "Other"
    },
    statuses = {
        "Active", "Contained", "Under Investigation", "Cleared"
    },
    hazards = {
        "Smoke", "Open Flame", "Structural Instability", "Hazardous Materials",
        "Electrical Hazard", "Fuel Leak", "Traffic", "Confined Space"
    },
    actionsTaken = {
        "Primary Search", "Secondary Search", "Fire Suppression", "Ventilation", "Rescue",
        "Medical Assistance", "Evacuation", "Overhaul", "Scene Secured"
    },
    equipmentUsed = {
        "SCBA", "Thermal Camera", "Attack Line", "Supply Line", "Foam Line",
        "Hydraulic Rescue Tools", "Ladder", "Water Monitor", "Fire Extinguisher"
    }
}
```
4. Configure report-sharing partners through the existing Jobs Base Share settings for each Fire job. `Config.Reports` only defines selectable catalogue values; it does not grant cross-job access. Received partner reports remain read-only.
5. With `Config.AutoExecuteQuery = true`, restart Fire once and let the built-in migration add `owner_job`, `shared_with_jobs`, and `idx_owner_updated`, then backfill existing report owners from `sky_jobs`. With automatic migration disabled, run the complete new `import.sql`; the exact migration is:```sql [migration.sql]
ALTER TABLE `sky_fire_reports`
    ADD COLUMN IF NOT EXISTS `owner_job` VARCHAR(50) NULL AFTER `report_type`,
    ADD COLUMN IF NOT EXISTS `shared_with_jobs` TEXT NULL AFTER `owner_job`,
    ADD INDEX IF NOT EXISTS `idx_owner_updated` (`owner_job`, `updated_at`);

UPDATE `sky_fire_reports` reports
INNER JOIN `sky_jobs` jobs ON jobs.id = reports.job_id
SET reports.owner_job = jobs.job
WHERE reports.owner_job IS NULL OR reports.owner_job = '';
```
6. Replace `config/locales` completely. No new inventory item, image, stream asset, or provider secret is required.
7. Restart Base, Jobs Base, and Fire in order. Test report creation/editing/search, current-scene capture, sharing and read-only access, mission autosave, progression-disabled vehicle-fire scale, rescue access for doorless/two-door vehicles, SCBA storage pressure, authorized prop placement, and extinguisher pickup permissions.

</template>

<template v-slot:prepare="">

Before updating, install Base `1.36.0` and Jobs Base `1.39.0`, stop the server, and back up the resource, intentional config edits, Job Configurator tables, and all `sky_fire_*` tables.

> Install `1.7.0` as one clean package. Its UI, runtime, locales, config defaults, and schema must match.

</template>

<template v-slot:files="">

Delete and reinsert the complete resource. At minimum replace `config/config.lua`, `import.sql`, the complete `config/locales` and `source` directories, and the built UI supplied with the package.

</template>

<template v-slot:config="">

Add the complete new report catalogue, which was absent in `1.6.1`:

```lua [config/config.lua]
Config.Reports = {
    types = {
        "Structure Fire", "Vehicle Fire", "Wildfire", "Hazmat", "Rescue", "Alarm", "Other"
    },
    statuses = {
        "Active", "Contained", "Under Investigation", "Cleared"
    },
    hazards = {
        "Smoke", "Open Flame", "Structural Instability", "Hazardous Materials",
        "Electrical Hazard", "Fuel Leak", "Traffic", "Confined Space"
    },
    actionsTaken = {
        "Primary Search", "Secondary Search", "Fire Suppression", "Ventilation", "Rescue",
        "Medical Assistance", "Evacuation", "Overhaul", "Scene Secured"
    },
    equipmentUsed = {
        "SCBA", "Thermal Camera", "Attack Line", "Supply Line", "Foam Line",
        "Hydraulic Rescue Tools", "Ladder", "Water Monitor", "Fire Extinguisher"
    }
}
```

`/jobconfig` does not manage `Config.Reports`; edit these plaintext lists to match department procedures. Normal configured Fire jobs still come from `Config.Jobs` or Job Configurator. Report sharing uses the existing Jobs Base Share configuration for each job and is separate from the catalogue lists. Do not add a partner job to `Config.Reports`; select it in the sharing settings instead.

</template>

<template v-slot:data="">

With `Config.AutoExecuteQuery = true`, the built-in migration updates report ownership and sharing. Otherwise execute the complete bundled `import.sql`, including:

```sql [migration.sql]
ALTER TABLE `sky_fire_reports`
    ADD COLUMN IF NOT EXISTS `owner_job` VARCHAR(50) NULL AFTER `report_type`,
    ADD COLUMN IF NOT EXISTS `shared_with_jobs` TEXT NULL AFTER `owner_job`,
    ADD INDEX IF NOT EXISTS `idx_owner_updated` (`owner_job`, `updated_at`);

UPDATE `sky_fire_reports` reports
INNER JOIN `sky_jobs` jobs ON jobs.id = reports.job_id
SET reports.owner_job = jobs.job
WHERE reports.owner_job IS NULL OR reports.owner_job = '';
```

New installations create `owner_job VARCHAR(50) NULL` and `shared_with_jobs TEXT NULL` in `sky_fire_reports` and include `KEY idx_owner_updated (owner_job, updated_at)`. The schema inherits the active database charset and collation. Existing rows without a matching `sky_jobs.id` cannot be backfilled automatically and should be reviewed before enabling sharing.

No new inventory item, image, stream asset, or provider credential is required.

</template>

<template v-slot:verify="">

- [ ] The console reports Base `1.36.0`, Jobs Base `1.39.0`, and Fire `1.7.0` in that order.
- [ ] `sky_fire_reports` contains `owner_job`, `shared_with_jobs`, and `idx_owner_updated`, and existing rows have the expected owner.
- [ ] Each configured report type, status, hazard, action, and equipment value appears and is searchable.
- [ ] The owning job can edit its report while a selected partner job sees the same report read-only with source context.
- [ ] Current-scene capture, evidence, people, hazards, actions, equipment, and report persistence work after restart.
- [ ] Mission form values/transforms autosave and vehicle-fire scale remains configured when progression is disabled.
- [ ] Doorless and two-door rescue cases work and repaired glass/doors synchronize.
- [ ] Storing equipped SCBA preserves bounded remaining pressure and clears active HUD/server state.
- [ ] Water-monitor and helicopter-bucket props require one-time server authorization.
- [ ] Unauthorized players cannot see or use the placeable-extinguisher pickup action.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-08-18" title="Version 1.6.1">
<template v-slot:body="">
<callout color="warning" icon="i-lucide-triangle-alert">

Update **sky_base** to `1.35.1` and **sky_jobs_base** to `1.38.1` before updating **sky_firejob**.

</callout>

**Highlights**

- Improved the built-in frontend fallback catalogue so missing translated creator, pump, dispatch, mission, and tablet keys remain readable.

**Notable Changes**

- Fixed an issue where a complete `1.6.0` feature installation could still show blank or placeholder Fire labels.

**Other Changes**

- Updated the package manifest for the `1.6.1` compatibility set.

**Changed Files**

- `sky_firejob/config/locales/*`
- `sky_firejob/fxmanifest.lua`

<update-guide from="1.6.0" resource="sky_firejob" to="1.6.1">
<template v-slot:simplified="">

1. Update Base to `1.35.1` and Jobs Base to `1.38.1`, stop the server, and back up Fire.
2. Delete the old resource and install the complete `1.6.1` package, especially its manifest, built UI, and locale defaults.
3. No public config value, `/jobconfig` key, SQL statement, item, image, production stream asset, or provider setting changed.
4. Restart dependencies and Fire, then verify creator, pump, dispatch, mission, and tablet screens show usable text.

</template>

<template v-slot:prepare="">

Update Base to `1.35.1` and Jobs Base to `1.38.1`, stop the server, and back up Fire.

> Install `1.6.1` as one clean package; a `.1` manifest beside the `.0` built UI is a mixed update.

</template>

<template v-slot:files="">

Delete and reinsert the resource. Replace `fxmanifest.lua`, the built UI, and `config/locales` completely.

</template>

<template v-slot:config="">

No public config value or `/jobconfig` key changed in `1.6.1`.

</template>

<template v-slot:data="">

No SQL, item, image, production stream asset, or provider credential changed.

</template>

<template v-slot:verify="">

- [ ] Base `1.35.1`, Jobs Base `1.38.1`, and Fire `1.6.1` start in order.
- [ ] Creator, pump, dispatch, mission, and tablet labels fall back to readable English when a translation key is absent.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-08-17" title="Version 1.6.0">
<template v-slot:body="">
<callout color="warning" icon="i-lucide-triangle-alert">

Update **sky_base** to `1.35.0` and **sky_jobs_base** to `1.38.0` before updating **sky_firejob**.

</callout>

**Highlights**

- **Dispatch response-plan requirements** - scenario drafts can select an existing Jobs Base response plan; automatic missions use its current eligibility/minimum-crew result and dispatches carry its keyword code.
- **Configured Fire job coverage** - hose/pump access, cross-resource Fire targets, player carry, tablet registration, and placeable-extinguisher removal consistently follow the configured Fire jobs.
- **Valve-aware pump hydraulics** - enhanced pump panels start with closed intake/tank valves, controls remain locked while off, and an external source supplies water only through an open connected intake.
- **Fire creator job permissions** - `/skyfiremenu` supports explicit framework/admin groups and explicit framework job names, with the same permission rechecked by creator callbacks.
- **Safer data migrations** - the hydrant setting moves from GPM to liters per second without discarding saved overrides, and oil-source plates expand from 16 to 64 characters.

**Notable Changes**

- Scenario create, copy, and update reject missing, stale, or mismatched response-plan job/code pairs. Scenario Hub imports deliberately start with the requirement disabled instead of trusting external identifiers.
- Configured Fire jobs are resolved consistently for hose/pump access, cross-resource fire targets, player carry, tablet registration, and placeable-extinguisher removal. Extinguisher removal now rechecks the configured job and duty rules on the server.
- The response-plan selector refreshes dynamic Jobs Base options, and Fire creator, pump, hydrant, extinguisher, and tablet text uses the shared language store across the bundled locales.

**Other Changes**

- Simple pump panels retain their compact legacy defaults; the closed-valve change applies to enhanced controls where each intake/tank path is operated explicitly.
- Existing `tankSupplyGpm` and `pumpSupplyGpm` settings remain in GPM. Only hydrant output is renamed and converted to liters per second.
- No new inventory item, image, or production stream asset is required by `1.6.0`.

**Changed Files**

- `sky_firejob/README.md`
- `sky_firejob/config/config.lua`
- `sky_firejob/config/locales/*`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/import.sql`
- `sky_firejob/source/*` — delete and reinsert

<update-guide from="1.5.0" resource="sky_firejob" to="1.6.0">
<template v-slot:simplified="">

1. Update **sky_base** to `1.35.0` and **sky_jobs_base** to `1.38.0`. Stop the server; back up the complete Fire resource, all saved scenarios, Job Configurator settings, and Fire database tables.
2. Delete the old `sky_firejob` folder and install the complete `1.6.0` package. Keep its manifest, `source`, rebuilt UI, locales, configuration, and SQL together.
3. Replace the old flat `/skyfiremenu` permission list with the complete new shape:```lua [config/config.lua]
Config.CommandPermissions.skyfiremenu = {
    groups = { "god", "superadmin", "admin" },
    jobs = {}
}
```

<br />

In `1.5.0`, this path was `{ "god", "superadmin", "admin" }`. `groups` continues through the existing framework/admin permission bridge. `jobs = {}` grants no job-based creator access; add exact framework job names only when those jobs should open and mutate the creator. A matching current job is sufficient; this list does not automatically expand to every configured Fire job.
4. Apply both hose configuration changes:<table>
<thead>
  <tr>
    <th>
      Config path
    </th>
    
    <th>
      <code>
        1.5.0
      </code>
    </th>
    
    <th>
      <code>
        1.6.0
      </code>
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      <code>
        Config.Hose.vehiclePumpBehavior.hydraulics.hydrantSupplyGpm
      </code>
    </td>
    
    <td>
      <code>
        1600.0
      </code>
    </td>
    
    <td>
      Removed
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.vehiclePumpBehavior.hydraulics.hydrantSupplyLitersPerSecond
      </code>
    </td>
    
    <td>
      Missing
    </td>
    
    <td>
      <code>
        100.0
      </code>
    </td>
  </tr>
</tbody>
</table>

<br />

In `/jobconfig`, the exact removed key is `hoseVehiclePumpHydraulicsHydrantSupplyGpm`; the replacement is `hoseVehiclePumpHydraulicsHydrantSupplyLitersPerSecond`. Saved values migrate at `GPM × 0.0630902` only when the replacement is absent, then the obsolete key is removed. Existing `tankSupplyGpm`, `pumpSupplyGpm`, hydrant models, and portable-pump configuration remain unchanged.
5. Scenario response-plan requirements do not add a `config.lua` field. Install Jobs Base `1.38.0` and the complete Fire UI/runtime, then open each scenario draft and deliberately select an available response plan if required. With a requirement enabled, its exact owner job and keyword code must still exist during create/copy/update; automatic selection uses the current plan eligibility/minimum crew. Without one, the scenario keeps its existing `minOnDuty` behavior. Imported Scenario Hub drafts start with this option disabled.
6. With `Config.AutoExecuteQuery = false`, run the complete `1.6.0` `import.sql`. Its exact update migration is:```sql [migration.sql]
ALTER TABLE `sky_fire_oil_spills`
    MODIFY COLUMN `source_plate` VARCHAR(64) NULL;

UPDATE `sky_jobs_configurator_settings`
SET `settings` = JSON_REMOVE(
        JSON_SET(
            `settings`,
            '$.hoseVehiclePumpHydraulicsHydrantSupplyLitersPerSecond',
            CAST(JSON_UNQUOTE(JSON_EXTRACT(
                `settings`,
                '$.hoseVehiclePumpHydraulicsHydrantSupplyGpm'
            )) AS DECIMAL(20, 6)) * 0.0630902
        ),
        '$.hoseVehiclePumpHydraulicsHydrantSupplyGpm'
    ),
    `revision` = `revision` + 1
WHERE `config_key` = 'sky_firejob'
    AND JSON_VALID(`settings`)
    AND JSON_CONTAINS_PATH(`settings`, 'one', '$.hoseVehiclePumpHydraulicsHydrantSupplyGpm')
    AND NOT JSON_CONTAINS_PATH(`settings`, 'one', '$.hoseVehiclePumpHydraulicsHydrantSupplyLitersPerSecond')
    AND JSON_UNQUOTE(JSON_EXTRACT(
        `settings`,
        '$.hoseVehiclePumpHydraulicsHydrantSupplyGpm'
    )) REGEXP '^-?[0-9]+([.][0-9]+)?$';

UPDATE `sky_jobs_configurator_settings`
SET `settings` = JSON_REMOVE(`settings`, '$.hoseVehiclePumpHydraulicsHydrantSupplyGpm'),
    `revision` = `revision` + 1
WHERE `config_key` = 'sky_firejob'
    AND JSON_VALID(`settings`)
    AND JSON_CONTAINS_PATH(`settings`, 'one', '$.hoseVehiclePumpHydraulicsHydrantSupplyGpm')
    AND JSON_CONTAINS_PATH(`settings`, 'one', '$.hoseVehiclePumpHydraulicsHydrantSupplyLitersPerSecond');
```

<br />

The automatic migration performs and verifies the equivalent conversion and stops visibly on invalid JSON, a non-numeric legacy value, or a failed write. The manual SQL deliberately leaves a non-numeric old-only value untouched; repair that saved override after backup instead of copying its number unchanged into the L/s field. All schemas inherit the active database character set and collation.
7. Restart Base, Jobs Base, and Fire in that order. Verify response-plan scenario creation/copy/update and automatic crew eligibility; group/job creator access; the existing hydrant and portable-pump flows; enhanced closed valves/off-state locks; open-intake supply/HUD/transfer behavior; extinguisher job/duty removal; tablet access; the saved GPM conversion; and a 64-character oil source plate.

</template>

<template v-slot:prepare="">

Update Base to `1.35.0` and Jobs Base to `1.38.0`. Stop the server; back up the complete Fire resource, saved scenario drafts/published scenarios, Job Configurator data, and all Fire tables.

> Install `1.6.0` as one complete package. The pump/HUD logic, response-plan UI/runtime, generated defaults, locales, manifest, and SQL migration must match.

</template>

<template v-slot:files="">

Delete and reinsert the complete resource. Replace `README.md`, `config/config.lua`, all `config/locales`, `fxmanifest.lua`, `import.sql`, `source`, and the built UI. No new item image or production stream file is added.

</template>

<template v-slot:config="">

Replace the old flat `Config.CommandPermissions.skyfiremenu = { "god", "superadmin", "admin" }` with:

```lua [config/config.lua]
Config.CommandPermissions.skyfiremenu = {
    groups = { "god", "superadmin", "admin" },
    jobs = {}
}
```

`groups` uses the existing framework/admin permission bridge. An empty `jobs` list grants no job-based access. Each added row must be an exact current framework job name; the server rechecks the same combined permission for the command and creator callbacks. Job permission does not implicitly include every configured Fire job.

Replace only the hydrant-output member inside `Config.Hose.vehiclePumpBehavior.hydraulics`:

```lua [config/config.lua]
-- 1.5.0: remove this field
hydrantSupplyGpm = 1600.0,

-- 1.6.0: add this field
hydrantSupplyLitersPerSecond = 100.0,
```

Do not rename `tankSupplyGpm` or `pumpSupplyGpm`. For `/jobconfig`, remove `hoseVehiclePumpHydraulicsHydrantSupplyGpm` and use `hoseVehiclePumpHydraulicsHydrantSupplyLitersPerSecond`; the shipped migration converts a saved old-only override by `× 0.0630902`, preserves an already-present new value, and removes the old key.

Response-plan requirements are saved per scenario, not in `config.lua` or `/jobconfig`. Select an exact plan from the current Jobs Base catalog. Enabled stale/removed plan pairs are rejected; no requirement preserves the existing scenario `minOnDuty` path, and imported Hub scenarios start disabled.

Enhanced pump panels now initialize explicit intake and tank-to-pump valves closed and keep controls locked while the pump is off. Simple panels retain their compact defaults. No configuration migration is needed for those state semantics.

</template>

<template v-slot:data="">

With automatic migration disabled, execute the complete new `import.sql`. The exact release migration is:

```sql [migration.sql]
ALTER TABLE `sky_fire_oil_spills`
    MODIFY COLUMN `source_plate` VARCHAR(64) NULL;

UPDATE `sky_jobs_configurator_settings`
SET `settings` = JSON_REMOVE(
        JSON_SET(
            `settings`,
            '$.hoseVehiclePumpHydraulicsHydrantSupplyLitersPerSecond',
            CAST(JSON_UNQUOTE(JSON_EXTRACT(
                `settings`,
                '$.hoseVehiclePumpHydraulicsHydrantSupplyGpm'
            )) AS DECIMAL(20, 6)) * 0.0630902
        ),
        '$.hoseVehiclePumpHydraulicsHydrantSupplyGpm'
    ),
    `revision` = `revision` + 1
WHERE `config_key` = 'sky_firejob'
    AND JSON_VALID(`settings`)
    AND JSON_CONTAINS_PATH(`settings`, 'one', '$.hoseVehiclePumpHydraulicsHydrantSupplyGpm')
    AND NOT JSON_CONTAINS_PATH(`settings`, 'one', '$.hoseVehiclePumpHydraulicsHydrantSupplyLitersPerSecond')
    AND JSON_UNQUOTE(JSON_EXTRACT(
        `settings`,
        '$.hoseVehiclePumpHydraulicsHydrantSupplyGpm'
    )) REGEXP '^-?[0-9]+([.][0-9]+)?$';

UPDATE `sky_jobs_configurator_settings`
SET `settings` = JSON_REMOVE(`settings`, '$.hoseVehiclePumpHydraulicsHydrantSupplyGpm'),
    `revision` = `revision` + 1
WHERE `config_key` = 'sky_firejob'
    AND JSON_VALID(`settings`)
    AND JSON_CONTAINS_PATH(`settings`, 'one', '$.hoseVehiclePumpHydraulicsHydrantSupplyGpm')
    AND JSON_CONTAINS_PATH(`settings`, 'one', '$.hoseVehiclePumpHydraulicsHydrantSupplyLitersPerSecond');
```

Automatic migration errors are intentionally visible and stop an unsafe silent reset. Manual SQL leaves an invalid old-only numeric value in place for explicit repair. The schema keeps `ENGINE=InnoDB` where required and inherits database charset/collation. There are no new tables or item definitions.

</template>

<template v-slot:verify="">

- [ ] Base `1.35.0`, Jobs Base `1.38.0`, and Fire `1.6.0` start in that order without migration errors.
- [ ] Group-only and exact job-based `/skyfiremenu` access match the new permission table, and unauthorized creator callbacks fail.
- [ ] Scenario create/copy/update accepts a current response plan, rejects a removed/stale pair, and automatic missions honor its minimum crew; a scenario without a plan still uses `minOnDuty`.
- [ ] Existing hydrant and portable-pump connections still work, enhanced pump valves start closed, controls stay locked while off, and an open connected intake changes supply, HUD, tank fill, or external vehicle transfer.
- [ ] Configured Fire job/duty rules apply to hose, pump, extinguisher removal, tablet, carry, and cross-resource Fire actions.
- [ ] The old saved GPM key is gone, its old-only value was converted by `0.0630902`, and an existing new L/s value was preserved.
- [ ] `sky_fire_oil_spills.source_plate` is `VARCHAR(64)`.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-08-12" title="Version 1.5.0">
<template v-slot:body="">
<callout color="warning" icon="i-lucide-triangle-alert">

Update **sky_base** to `1.34.0` and **sky_jobs_base** to `1.37.0` before updating **sky_firejob**.

</callout>

**Highlights**

- **Configurable wildfire protective mask** - a new item, clothing requirement, HUD state, and Job Configurator section reduce normal smoke exposure while intentionally retaining weak toxic-smoke protection and no heat protection.
- **More responsive hose handling** - held nozzles update independently from background route simulation, while laid routes remove redundant straight-line points and sample stable ground positions for smoother rendering.
- **Cross-job oil cleanup** - additional configured jobs can receive only the oil-cleanup actions, with authoritative job and duty validation on client and server.
- **Objective-specific society rewards** - fire, oil, tree, and rescue objectives can each pay the configured society independently from other scenario reward paths.

**Notable Changes**

- Pump controls fall back to the vehicle area when a model has no saved panel position; explicitly configured models continue using their editor-defined panel target.
- Scenario vehicles remain frozen at their saved transform until runtime needs them, and aircraft fire effects are capped so tall model bounds no longer place flames too high.
- Scenario Hub publishing uses the production service, server-side thumbnail uploads, and the packaged Lua 5.4-compatible signing module with verified SHA/HMAC vectors; no private credential is exposed in public configuration.

**Other Changes**

- All newly added and revised user-facing feedback follows the selected locale; Italian was added and German, English, and Serbian were updated.
- Shared form buttons, fields, selectors, switches, checkboxes, ranges, and date ranges were synchronized with Jobs Base.
- Focused regression coverage was expanded across the release.

**Changed Files**

- `sky_firejob/config/config.lua`
- `sky_firejob/config/inventory/fire_protective_mask.png`
- `sky_firejob/config/locales/*`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/source/*` — delete and reinsert

<update-guide from="1.4.0" resource="sky_firejob" to="1.5.0">
<template v-slot:simplified="">

1. Update **sky_base** to `1.34.0` and **sky_jobs_base** to `1.37.0`. Stop the server and back up the complete Fire resource plus all saved Job Configurator overrides.
2. Delete the old `sky_firejob` folder and install the complete `1.5.0` package. Keep the new manifest, `source`, built UI, all locales, and `config/inventory/fire_protective_mask.png` together.
3. Apply every config change below. Each **Absent -> New** value did not exist in `1.4.0`.

Add the item to every intended `Config.Jobs[*].shop`; it was absent in `1.4.0`:

```lua [config/config.lua]
{ name = "fire_protective_mask", label = "Wildfire Protective Mask", price = 175 },
```

Add the complete shipped block at `Config.FireSystem.protectiveGear.breathing.protectiveMask`:

```lua [config/config.lua]
protectiveMask = {
    enabled = true,
    smokeExposureMultiplier = 0.15,
    toxicSmokeExposureMultiplier = 0.85,
    maskOverlay = {
        enabled = false,
        forceFirstPerson = false
    },
    item = {
        enabled = true,
        name = "fire_protective_mask"
    },
    requiredComponents = {
        { component = 1, gearKey = "mask", label = "wildfire protective mask", drawable = 46, texture = 0 }
    },
    femaleRequiredComponents = {
        { component = 1, gearKey = "mask", label = "wildfire protective mask", drawable = 46, texture = 0 }
    }
},
```

`requiredProps` and `femaleRequiredProps` are supported optional fields, but they are not rows in the shipped `1.5.0` block. Omit them when no prop is required, or add these explicit empty defaults with the same behavior:

```lua [config/config.lua]
Config.FireSystem.protectiveGear.breathing.protectiveMask.requiredProps = {}
Config.FireSystem.protectiveGear.breathing.protectiveMask.femaleRequiredProps = {}
```

`smokeExposureMultiplier = 0.15` leaves 15% of normal smoke exposure. `toxicSmokeExposureMultiplier = 0.85` intentionally leaves 85% of toxic exposure, so SCBA remains necessary. This mask does not modify heat exposure.

Add the new cleanup whitelist beside the existing cleanup fields:

```lua [config/config.lua]
Config.OilSpills.cleanup.allowedJobs = { "mechanic" }
```

Configured Fire jobs are always authorized. This list adds non-Fire jobs; it does not replace the configured Fire jobs. An empty `{}` means no additional jobs, while the configured Fire jobs still retain cleanup access. Existing `Config.OilSpills.cleanup.requireOnDuty = true` applies to every authorized job.

Replace the complete society-reward block so every new `scenarioEnabled` value sits beside its existing `enabled` and `jobs` values:

```lua [config/config.lua]
Config.SocietyRewards = {
    fire = {
        enabled = true,
        scenarioEnabled = true,
        jobs = {}
    },
    oil = {
        enabled = true,
        scenarioEnabled = true,
        jobs = {}
    },
    tree = {
        enabled = true,
        scenarioEnabled = true,
        jobs = {}
    },
    rescue = {
        enabled = true,
        scenarioEnabled = true,
        jobs = {}
    }
}
```

For each objective, `enabled` controls all society payments and `scenarioEnabled` separately controls Mission Creator objective payments. An empty `jobs = {}` falls back to the applicable incident recipient list and then to all configured Fire jobs: mission objectives use `Config.FireScenarioCreator.dispatch.jobs`; ordinary tree incidents use `Config.TreeIncident.dispatch.jobs`; ordinary fire, oil, and rescue completions use `Config.FireSystem.dispatch.jobs`. The default amounts remain fire `250`, oil `150`, tree `500`, and rescue `750` unless per-job reward rows override them.

**Exact /jobconfig keys**

- Protective mask: `fireProtectiveMaskEnabled`, `fireProtectiveMaskSmokeMultiplier`, `fireProtectiveMaskToxicMultiplier`, `fireProtectiveMaskOverlayEnabled`, `fireProtectiveMaskForceFirstPerson`, `fireProtectiveMaskItemEnabled`, `fireProtectiveMaskItemName`, `fireProtectiveMaskComponents`, `fireProtectiveMaskProps`, `fireFemaleProtectiveMaskComponents`, and `fireFemaleProtectiveMaskProps`.
- Cleanup: `oilCleanupAllowedJobs`; an empty saved list has the same no-additional-jobs meaning described above.
- Rewards: `societyRewardFireEnabled`, `societyRewardFireScenarioEnabled`, `societyRewardFireJobs`; the matching `Oil`, `Tree`, and `Rescue` key trios use those exact suffixes.

Saved `/jobconfig` values override the Lua defaults. Review both shipped component lists. `fireProtectiveMaskProps` and `fireFemaleProtectiveMaskProps` remain supported optional saved keys; leave them absent or empty unless the mask requires prop variants.

**Pump-panel fallback and editors**

- `Config.Hose.vehicles[*].pumpPanelConfigured` is new. For a legacy entry where the flag is absent, the runtime infers a configured panel only when all three saved panel coordinates exist and at least one coordinate or the panel size differs from the default offset/size. Otherwise an absent flag uses the whole vehicle area as the interaction fallback. Explicit `false` always uses that fallback.
- In `/jobconfig`, use the vehicle card's **Hose Control access** action (`pumpPanelAccess`). Saving that editor writes `pumpPanelX`, `pumpPanelY`, `pumpPanelZ`, `pumpPanelSize`, and sets `pumpPanelConfigured = true` for that model.
- Set `pumpDischargeCount` (`1`-`4`) and `pumpIntakeCount` (`1`-`2`), then use `pumpOutlet1Connection` through `pumpOutlet4Connection` and `pumpIntake1Connection` through `pumpIntake2Connection`. Each active connection saves its `Label`, `X`, `Y`, `Z`, `Rx`, `Ry`, and `Rz` fields under the matching `pumpOutletN*` or `pumpIntakeN*` prefix.
- Do not copy the packaged model's panel, intake, or outlet numbers into another vehicle. Open each action on the actual model and save its own position, rotation, and panel size.

**Files, inventory, and restart**

No SQL migration is required. Register the non-consumable `fire_protective_mask` item in the active inventory, keep that exact name in the shop and mask config, and install `config/inventory/fire_protective_mask.png` at the same path. No other inventory item or image is added by this release.

Restart **sky_base**, **sky_jobs_base**, and **sky_firejob** in that order. Verify mask purchase/use, both shipped component lists and any optional prop overrides, extra-job cleanup with on-duty enforcement, all four ordinary and mission reward paths, both the legacy-panel inference and unconfigured vehicle-area fallback, and editor-saved panel/intake/outlet targets on each custom model.

</template>

<template v-slot:prepare="">

Stop the server after both dependencies are current. Back up the complete Fire resource, custom clothing values, shops, hose vehicle entries, cleanup access, reward settings, and saved `/jobconfig` overrides.

> Install one complete `1.5.0` package. The mask item, clothing checks, HUD, locale, generated settings, server validation, hose runtime, manifest, and image must match.

</template>

<template v-slot:files="">

Replace `fxmanifest.lua`, `source`, the complete built UI, and `config/locales`. Copy `config/inventory/fire_protective_mask.png`. Merge the public values below into the new `config/config.lua` or configure their saved equivalents after startup.

</template>

<template v-slot:config="">

Add the mask to each intended `Config.Jobs[*].shop`; this row was absent in `1.4.0`:

```lua [config/config.lua]
{ name = "fire_protective_mask", label = "Wildfire Protective Mask", price = 175 },
```

Add the complete shipped protective-mask block at `Config.FireSystem.protectiveGear.breathing.protectiveMask`:

```lua [config/config.lua]
protectiveMask = {
    enabled = true,
    smokeExposureMultiplier = 0.15,
    toxicSmokeExposureMultiplier = 0.85,
    maskOverlay = {
        enabled = false,
        forceFirstPerson = false
    },
    item = {
        enabled = true,
        name = "fire_protective_mask"
    },
    requiredComponents = {
        {
            component = 1,
            gearKey = "mask",
            label = "wildfire protective mask",
            drawable = 46,
            texture = 0
        }
    },
    femaleRequiredComponents = {
        {
            component = 1,
            gearKey = "mask",
            label = "wildfire protective mask",
            drawable = 46,
            texture = 0
        }
    }
},
```

This entire shipped table is **Absent -> New**. `requiredProps` and `femaleRequiredProps` are supported optional fields and exact `/jobconfig` keys, but they are not shipped config rows. Omit them when no prop is required, or add the following explicit empty defaults with identical behavior:

```lua [config/config.lua]
Config.FireSystem.protectiveGear.breathing.protectiveMask.requiredProps = {}
Config.FireSystem.protectiveGear.breathing.protectiveMask.femaleRequiredProps = {}
```

A multiplier of `0.15` leaves 15% of normal smoke exposure. The `0.85` toxic multiplier deliberately leaves 85% of toxic exposure; SCBA remains required. The mask does not change heat exposure.

Apply the remaining public config changes:

<table>
<thead>
  <tr>
    <th>
      Config path
    </th>
    
    <th>
      <code>
        1.5.0
      </code>
      
       shipped value / action
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      Hose vehicle <code>
        pumpPanelConfigured
      </code>
    </td>
    
    <td>
      Absent -> New: a legacy non-default panel is inferred when the flag is absent; otherwise absent/<code>
        false
      </code>
      
       falls back to the vehicle area, and the editor saves explicit <code>
        true
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.OilSpills.cleanup.allowedJobs
      </code>
    </td>
    
    <td>
      Absent -> New: <code>
        { "mechanic" }
      </code>
      
      ; configured Fire jobs remain authorized automatically
    </td>
  </tr>
</tbody>
</table>

`Config.OilSpills.cleanup.allowedJobs` only adds non-Fire jobs. An empty `{}` means no additional jobs, while every configured Fire job remains authorized. Existing `Config.OilSpills.cleanup.requireOnDuty = true` applies to both configured Fire jobs and extra whitelist entries.

Replace the complete reward block so the four new switches stay beside their existing neighbors:

```lua [config/config.lua]
Config.SocietyRewards = {
    fire = {
        enabled = true,
        scenarioEnabled = true,
        jobs = {}
    },
    oil = {
        enabled = true,
        scenarioEnabled = true,
        jobs = {}
    },
    tree = {
        enabled = true,
        scenarioEnabled = true,
        jobs = {}
    },
    rescue = {
        enabled = true,
        scenarioEnabled = true,
        jobs = {}
    }
}
```

Each `scenarioEnabled` field is **Absent -> New: true**. `enabled` controls all payments; `scenarioEnabled` separately gates Mission Creator objective payments. Empty `jobs` first uses the applicable incident recipients and then all configured Fire jobs: mission objectives use `Config.FireScenarioCreator.dispatch.jobs`, ordinary tree incidents use `Config.TreeIncident.dispatch.jobs`, and ordinary fire, oil, and rescue completions use `Config.FireSystem.dispatch.jobs`. Default amounts remain fire `250`, oil `150`, tree `500`, and rescue `750` unless saved job rows override them.

For hose vehicles, `pumpPanelConfigured` is an editor-managed hidden flag. A legacy entry with no flag is inferred as configured only when `pumpPanelX`, `pumpPanelY`, and `pumpPanelZ` all exist and at least one coordinate or `pumpPanelSize` differs from the default offset/size. Every other absent flag, and every explicit `false`, validly falls back to the vehicle area. For a precise target, open the vehicle card's **Hose Control access** action (`pumpPanelAccess`) on that actual model; saving writes `pumpPanelX`, `pumpPanelY`, `pumpPanelZ`, `pumpPanelSize`, and explicit `pumpPanelConfigured = true`.

Set `pumpDischargeCount` (`1`-`4`) and `pumpIntakeCount` (`1`-`2`), then use the actions `pumpOutlet1Connection` through `pumpOutlet4Connection` and `pumpIntake1Connection` through `pumpIntake2Connection`. Each active action saves its `Label`, `X`, `Y`, `Z`, `Rx`, `Ry`, and `Rz` values under the matching `pumpOutletN*` or `pumpIntakeN*` prefix. Never copy the packaged model's panel, intake, outlet, or rotation values to another model; edit and save the actual vehicle.

With `/jobconfig`, review these exact saved keys:

- Mask: `fireProtectiveMaskEnabled`, `fireProtectiveMaskSmokeMultiplier`, `fireProtectiveMaskToxicMultiplier`, `fireProtectiveMaskOverlayEnabled`, `fireProtectiveMaskForceFirstPerson`, `fireProtectiveMaskItemEnabled`, `fireProtectiveMaskItemName`, `fireProtectiveMaskComponents`, `fireProtectiveMaskProps`, `fireFemaleProtectiveMaskComponents`, and `fireFemaleProtectiveMaskProps`.
- Cleanup: `oilCleanupAllowedJobs`.
- Fire reward: `societyRewardFireEnabled`, `societyRewardFireScenarioEnabled`, and `societyRewardFireJobs`.
- Oil reward: `societyRewardOilEnabled`, `societyRewardOilScenarioEnabled`, and `societyRewardOilJobs`.
- Tree reward: `societyRewardTreeEnabled`, `societyRewardTreeScenarioEnabled`, and `societyRewardTreeJobs`.
- Rescue reward: `societyRewardRescueEnabled`, `societyRewardRescueScenarioEnabled`, and `societyRewardRescueJobs`.

Saved values override Lua defaults. Review both shipped mask component lists; the two prop keys may remain absent or empty unless prop variants are required. Save each affected vehicle card after using its panel/intake/outlet actions.

</template>

<template v-slot:data="">

No SQL migration is required. Register the non-consumable `fire_protective_mask` item according to the active inventory and install `config/inventory/fire_protective_mask.png`. Keep the item name identical in the inventory, Fire shop, and protective-mask config. This release adds no other inventory item or image.

Scenario Hub deployment credentials remain server-only. Preserve the packaged runtime and configure credentials only through the protected deployment path; never paste a secret into config, logs, support messages, or public documentation. Restart **sky_base**, **sky_jobs_base**, and **sky_firejob** in that order.

</template>

<template v-slot:verify="">

- [ ] Base `1.34.0`, Jobs Base `1.37.0`, and Fire `1.5.0` start in order.
- [ ] The protective mask can be bought/used, validates the intended clothing, updates the HUD, reduces normal smoke, and does not replace SCBA or heat gear.
- [ ] Authorized extra jobs see only cleanup actions and lose access when job/duty requirements fail.
- [ ] Fire, oil, tree, and rescue society rewards follow their individual `scenarioEnabled` and `enabled` values.
- [ ] A legacy non-default pump panel is inferred without the new flag, an editor-saved panel uses explicit `true`, and every unconfigured or explicit-`false` model remains accessible through the vehicle-area fallback.
- [ ] Held and laid hoses remain responsive, grounded, smooth, and synchronized over long routes.
- [ ] Scenario vehicles retain saved positions and aircraft effects remain at a plausible height.
- [ ] Scenario publishing and thumbnail uploads succeed without exposing credentials.
- [ ] Equipment and placement feedback follows the selected locale.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-08-03" title="Version 1.4.0">
<template v-slot:body="">
<callout color="warning" icon="i-lucide-triangle-alert">

Update **sky_base** to `1.33.0` and **sky_jobs_base** to `1.36.0` before updating **sky_firejob**.

</callout>

**Highlights**

- **Accurate 100-meter hose routes** - attack and monitor hoses retain their laid path, follow outdoor terrain and MLO floors, keep stable truck-side bends, and render smoother corners without deleting long routes.
- **Configured pump interaction points** - pump panels, intakes, discharges, monitor supply, and vehicle-transfer actions use the editor-defined positions and rotations for each vehicle model.
- **Reliable water-monitor supply** - the nearest outlet is reserved while the hose is carried, remains occupied after connection, and is released correctly on every abort or disconnect path.
- **All configured Fire jobs supported** - permissions, dispatch recipients, rewards, maintenance, creator triggers, and exported actions derive from the active Fire job configuration instead of a hard-coded job name.
- **Signed Scenario Hub requests** - remote Scenario Hub traffic now uses server-side request signing and provides safe diagnostics for availability and signature mismatches.

**Notable Changes**

- Vehicle entrapment uses the configured body/engine damage thresholds instead of obsolete speed thresholds.
- Enhanced pumps shut down when fuel reaches zero and cannot be re-engaged until refueled.
- Grounded nozzles have configurable placement, rotation, interaction distance, target size, deployment distance, and handling animation.
- Vehicle water-transfer actions share the pump target and use the nearest configured intake/outlet geometry.
- Fire dispatch preserves the initiating player, and rejected dispatch creation is logged clearly.
- Fire carry uses the central Jobs Base runtime and can explicitly allow or reject carrier vehicles.
- The breathing HUD keeps its SCBA gauge, mask overlay, and heat warnings while hiding the removed equipment silhouette.
- Added a complete Serbian locale and ordered NUI image-source support.

**Other Changes**

- Updated the streamed hose material for a matte cloth appearance.
- Deterministic config loading prevents duplicate registration, and blip values are normalized before reaching FiveM natives.
- Added focused regression coverage for configured jobs, pump targets/rotation, transfer targets, dispatch, hose sync, entrapment, radial exports, and rewards.

**Changed Files**

- `sky_firejob/config/config.lua`
- `sky_firejob/config/locales/*`
- `sky_firejob/fxmanifest.lua`
- `sky_firejob/README.md`
- `sky_firejob/source/*` — delete and reinsert
- `sky_firejob/stream/sky_hose_segment.ydr`

<update-guide from="1.3.1" resource="sky_firejob" to="1.4.0">
<template v-slot:simplified="">

1. Update **sky_base** to `1.33.0` and **sky_jobs_base** to `1.36.0`.
2. Back up Fire, delete the old folder, and install the complete `1.4.0` package including runtime, UI, locales, tests, README, manifest, and stream assets.
3. Without `/jobconfig`, add `Config.PlayerCarry.allowCarrierInVehicle = false`; change extinguisher maintenance `allowedJobs` to `{}`; remove `Config.InteriorExtinguishers.stock.storageJob`; and remove the obsolete entrapment fields `minImpactSpeedKmh` and `minSpeedDropKmh`.
4. Add the complete new Hose values: grounded offset `-0.38`; rotation `90.0/0.0/90.0`; pump target distance `2.0`; target size `0.35`; ground animation `pickup_object` / `pickup_low` with `1200`, `650`, flag `0`; deploy distance `6.0`; and change max length from `55.0` to `100.0`.
5. Change the `jobs` lists for scenario random triggers, scenario dispatch, all four society rewards, tree dispatch, and fire dispatch from the old `firefighter` entries to `{}`. Empty means all currently configured Fire jobs.
6. Every `Config.Hose.vehicles` entry now needs editor-saved pump-panel `X/Y/Z/size` plus `X/Y/Z/Rx/Ry/Rz` for each active intake and outlet. Do not copy the shipped example coordinates to another model; configure every vehicle through `/jobconfig` or the vehicle editor. The shipped example changes from four to three discharges.
7. With `/jobconfig`, review and save Carry, Hose/nozzle behavior, per-vehicle pump geometry, entrapment, extinguisher maintenance, incident recipients, and reward recipients after installing the package.
8. Keep the new `stream/sky_hose_segment.ydr`; no SQL migration or inventory item is required. Configure Scenario Hub signing only through the protected deployment path, then restart Base, Jobs Base, and Fire.

</template>

<template v-slot:prepare="">

Back up the complete Fire resource and intentional configuration. Install cleanly so runtime, UI, job configuration, HMAC support, manifest, and streamed hose model are from the same package.

</template>

<template v-slot:files="">

Replace `fxmanifest.lua`, `source`, built UI, locales, README, tests, and `stream/sky_hose_segment.ydr`. Keep `source/server/vendor/sha2.lua` in the package.

</template>

<template v-slot:config="">

Without `/jobconfig`, apply all of these public changes:

<table>
<thead>
  <tr>
    <th>
      Config path
    </th>
    
    <th>
      <code>
        1.4.0
      </code>
      
       shipped value / action
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      <code>
        Config.PlayerCarry.allowCarrierInVehicle
      </code>
    </td>
    
    <td>
      New: <code>
        false
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.InteriorExtinguishers.maintenance.allowedJobs
      </code>
    </td>
    
    <td>
      Changed to <code>
        {}
      </code>
      
      ; empty means all configured Fire jobs
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.InteriorExtinguishers.stock.storageJob
      </code>
    </td>
    
    <td>
      Removed; storage ownership follows the active configured Fire job
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.groundedNozzleOffset
      </code>
    </td>
    
    <td>
      New: <code>
        -0.38
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.groundedNozzleRotation.pitch/roll/headingOffset
      </code>
    </td>
    
    <td>
      New: <code>
        90.0
      </code>
      
      , <code>
        0.0
      </code>
      
      , <code>
        90.0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.pumpTargetDistance
      </code>
    </td>
    
    <td>
      New: <code>
        2.0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.pumpTargetSize
      </code>
    </td>
    
    <td>
      New: <code>
        0.35
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.groundActionAnimation.enabled
      </code>
    </td>
    
    <td>
      New: <code>
        true
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.groundActionAnimation.dict
      </code>
    </td>
    
    <td>
      New: <code>
        "pickup_object"
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.groundActionAnimation.layDownName/pickUpName
      </code>
    </td>
    
    <td>
      New: <code>
        "pickup_low"
      </code>
      
      , <code>
        "pickup_low"
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.groundActionAnimation.durationMs/transitionMs/flag
      </code>
    </td>
    
    <td>
      New: <code>
        1200
      </code>
      
      , <code>
        650
      </code>
      
      , <code>
        0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.deployDistance
      </code>
    </td>
    
    <td>
      New: <code>
        6.0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.maxLength
      </code>
    </td>
    
    <td>
      Changed from <code>
        55.0
      </code>
      
       to <code>
        100.0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.VehicleRescue.playerEntrapment.minImpactSpeedKmh
      </code>
    </td>
    
    <td>
      Removed
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.VehicleRescue.playerEntrapment.minSpeedDropKmh
      </code>
    </td>
    
    <td>
      Removed
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.FireScenarioCreator.randomTrigger.jobs
      </code>
    </td>
    
    <td>
      Changed to <code>
        {}
      </code>
      
      ; empty means all configured Fire jobs
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.FireScenarioCreator.dispatch.jobs
      </code>
    </td>
    
    <td>
      Changed to <code>
        {}
      </code>
      
      ; empty means all configured Fire jobs
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.SocietyRewards.fire/oil/tree/rescue.jobs
      </code>
    </td>
    
    <td>
      Changed to <code>
        {}
      </code>
      
      ; rewards derive from configured Fire jobs and saved Job Configurator values
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.TreeIncident.dispatch.jobs
      </code>
    </td>
    
    <td>
      Changed to <code>
        {}
      </code>
      
      ; empty means all configured Fire jobs
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.FireSystem.dispatch.jobs
      </code>
    </td>
    
    <td>
      Changed to <code>
        {}
      </code>
      
      ; empty means all configured Fire jobs
    </td>
  </tr>
</tbody>
</table>

For every entry in `Config.Hose.vehicles`, keep the current editor-saved pump panel `X/Y/Z/size`, each active `pumpOutletN` position and rotation (`X/Y/Z/Rx/Ry/Rz`), and each active `pumpIntakeN` position and rotation. The shipped example now uses three discharges rather than four. Do not copy the example coordinates to a different vehicle model; position them through `/jobconfig` or the vehicle editor.

With `/jobconfig`, review and save Hose nozzle placement/animation, deployment and maximum length, target size/distance, per-vehicle panel/intake/outlet geometry, Carry vehicle behavior, entrapment detection, incident dispatch, extinguisher maintenance, and reward recipients. The empty job lists intentionally select the current configured Fire jobs.

</template>

<template v-slot:data="">

No SQL migration, inventory item, or image registration is required. Replace `stream/sky_hose_segment.ydr`; mixed clients can otherwise render a different hose material than `1.4.0` clients.

Scenario Hub signing requires the deployment secret and key version to match the Public API. Never place the secret in public config, changelog, support messages, or AI knowledge.

</template>

<template v-slot:verify="">

- [ ] Base `1.33.0`, Jobs Base `1.36.0`, and Fire `1.4.0` are running.
- [ ] Every configured Fire job receives intended radial actions, dispatches, rewards, maintenance, and creator access.
- [ ] Pump targets appear at editor-defined points on each configured vehicle model.
- [ ] Monitor and transfer hoses reserve and render the intended nearest ports.
- [ ] A routed hose remains grounded and connected across slopes, MLO floors, and long paths up to 100 meters.
- [ ] The enhanced pump shuts down at zero fuel.
- [ ] Damage-based entrapment, Fire dispatch, Scenario Hub availability, carry, and image fallbacks work correctly.
- [ ] The updated streamed hose has the intended matte cloth appearance.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-07-29" title="Version 1.3.1">
<template v-slot:body="">
<callout color="warning" icon="i-lucide-triangle-alert">

Update **sky_base** to `1.32.1` and **sky_jobs_base** to `1.35.1` before updating **sky_firejob**.

</callout>

**Highlights**

- **Simple and enhanced firetruck pump panels** - choose automatic one-intake/one-discharge operation or a full manual panel with configurable pressure, RPM, tank feed/fill, up to two intakes, and up to four hose discharges.
- **Realistic pump hydraulics and stress** - supply capacity, hose friction, cavitation, dry running, fuel consumption, heat, overload warnings, pressure loss, and gradual engine damage now respond to live pump use.
- **Per-vehicle pump configuration** - `/jobconfig` can configure pump mode, tanks, intake/outlet counts, custom port labels, and attachment positions through dedicated vehicle cards and connection editors.
- **Placeable attack hoses** - firefighters can lay their attack nozzle and hose on the ground, retrieve it later, and keep the grounded hose synchronized for nearby players.
- **Restored protective-gear HUD** - the breathing display again shows the complete firefighter equipment silhouette with clear missing-item highlights.

**Notable Changes**

- Pump outlets control their own hose assignment and flow state, while the panel updates live as supply, tank, fuel, valve, and stress values change.
- Vehicle deck-gun controls appear only when the configured turret exists on the spawned vehicle.
- Portable drafting uses a server-authoritative natural-water allowlist and supports longer, submerged intake lines.
- Grounded hoses align with the nozzle, follow MLO floors, and clean up when their vehicle disappears.
- Tank filling, pump supply, water monitors, deck guns, and hose flow now respect the active valve, pressure, and source state.
- Players can be rescued through vehicle doors that were already missing before entrapment state synchronized.
- Fire water operations and exported actions recognize every Fire job configured through the in-game configurator.
- Incident Reports and other embedded Fire apps fill the shared tablet correctly.
- Air-bottle storage closes with Escape and gauge-based interfaces initialize more reliably.

**Other Changes**

- Reduced client work for death checks, hose pathing, pump state, fuel, temperature, and damage updates while preserving responsive controls.
- Improved English action feedback and completed German Fire and pump-panel translations.
- Added regression coverage for pump modes, hydraulics, overload, connections, hose synchronization, tablet handoff, authorization, and locale parity.

<update-guide from="1.3.0" resource="sky_firejob" to="1.3.1">
<template v-slot:simplified="">

1. Update **sky_base** to `1.32.1` and **sky_jobs_base** to `1.35.1`.
2. Download **sky_firejob** `1.3.1`, then back up the resource and customized config files.
3. Delete the old resource folder and install the complete new folder, including the rebuilt interface.
4. Keep the new pump-control runtime, pump-panel interface, locales, and protective-gear HUD assets.
5. Configure valid natural-water areas manually in `Config.Hose.pump.waterSourceAreas`.
6. Without `/jobconfig`, merge every new pump-control, vehicle behavior, hydraulics, and vehicle-port value listed below.
7. With `/jobconfig`, review and save the new **Pump Panel** section; the three portable-drafting values remain manual.
8. No SQL migration or new inventory item is required.
9. Restart **sky_base**, **sky_jobs_base**, and **sky_firejob** in that order.

</template>

<template v-slot:prepare="">

Stop the server after updating both base resources. Create these backups:

<table>
<thead>
  <tr>
    <th>
      Back up
    </th>
    
    <th>
      Safe location
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      Complete <code>
        sky_firejob
      </code>
      
       folder
    </td>
    
    <td>
      Outside the live <code>
        resources
      </code>
      
       folder
    </td>
  </tr>
  
  <tr>
    <td>
      Customized config/editor/function files
    </td>
    
    <td>
      Separate <code>
        custom-config
      </code>
      
       folder
    </td>
  </tr>
</tbody>
</table>

> Do not overlay `1.3.1` on `1.3.0`. The pump runtime and interface were expanded substantially.

</template>

<template v-slot:files="">

Install the complete package:

<table>
<thead>
  <tr>
    <th>
      Action
    </th>
    
    <th>
      Current server path
    </th>
    
    <th>
      New package / destination
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      <strong>
        Delete
      </strong>
    </td>
    
    <td>
      <code>
        resources/[sky]/sky_firejob
      </code>
    </td>
    
    <td>
      Remove only after the backup exists
    </td>
  </tr>
  
  <tr>
    <td>
      <strong>
        Copy
      </strong>
    </td>
    
    <td>
      —
    </td>
    
    <td>
      Copy the complete new <code>
        sky_firejob
      </code>
      
       folder
    </td>
  </tr>
  
  <tr>
    <td>
      <strong>
        Keep from new release
      </strong>
    </td>
    
    <td>
      <code>
        fxmanifest.lua
      </code>
      
      , <code>
        source
      </code>
      
      , and <code>
        source/html
      </code>
    </td>
    
    <td>
      Required for both pump panels, hydraulics, hose placement, rescue, and tablet fixes
    </td>
  </tr>
  
  <tr>
    <td>
      <strong>
        Keep from new release
      </strong>
    </td>
    
    <td>
      <code>
        config/locales
      </code>
    </td>
    
    <td>
      Contains the current English and German UI copy
    </td>
  </tr>
  
  <tr>
    <td>
      <strong>
        Keep from new release
      </strong>
    </td>
    
    <td>
      Rebuilt frontend assets
    </td>
    
    <td>
      Contains the pump gauges, panel views, and protective-gear HUD imagery
    </td>
  </tr>
  
  <tr>
    <td>
      <strong>
        Merge only your values
      </strong>
    </td>
    
    <td>
      Backed-up config/editor/function files
    </td>
    
    <td>
      Reapply intentional customizations inside the matching new files
    </td>
  </tr>
</tbody>
</table>
</template>

<template v-slot:config="">

Start with the **new** `config/config.lua`. The complete public `1.3.0 → 1.3.1` config migration is listed below.

<lua-diff-reference>

Compare `sky_firejob/config/config.lua`. Keep the NEW file and transfer only intentional server-specific values.

</lua-diff-reference>

<accordion>
<accordion-item label="1 · Portable drafting values — always manual">

These three values are **not** managed by `/jobconfig` and must be present in `Config.Hose.pump` on every server:

<table>
<thead>
  <tr>
    <th>
      Config path
    </th>
    
    <th>
      Shipped value / required action
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      <code>
        Config.Hose.pump.intakeExtraLength
      </code>
    </td>
    
    <td>
      <code>
        5.0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.pump.intakeSubmergeDepth
      </code>
    </td>
    
    <td>
      <code>
        0.55
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.pump.waterSourceAreas
      </code>
    </td>
    
    <td>
      Add one or more trusted <code>
        { coords, radius, zTolerance }
      </code>
      
       areas that cover the natural-water locations where drafting is allowed
    </td>
  </tr>
</tbody>
</table>

Replace the shipped example area with locations appropriate for your map:

```lua [config/config.lua]
Config.Hose.pump.waterSourceAreas = {
    {
        coords = vector3(1300.0, 4100.0, 30.0),
        radius = 850.0,
        zTolerance = 4.0
    }
}
```

`Config.Hose.pump.naturalWaterEnabled` remains the existing master switch. When enabled, drafting outside `waterSourceAreas` is rejected.

</accordion-item>

<accordion-item label="2 · Panel mode and pressure controls">

Add the complete new blocks:

<table>
<thead>
  <tr>
    <th>
      Config path
    </th>
    
    <th>
      Shipped value
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      <code>
        Config.Hose.pumpPanelStyle
      </code>
    </td>
    
    <td>
      <code>
        "enhanced"
      </code>
      
      ; use <code>
        "simple"
      </code>
      
       for automatic one-intake/one-discharge operation
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.pumpControl.minPressure
      </code>
    </td>
    
    <td>
      <code>
        50
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.pumpControl.maxPressure
      </code>
    </td>
    
    <td>
      <code>
        600
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.pumpControl.pressureStep
      </code>
    </td>
    
    <td>
      <code>
        25
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.pumpControl.presetPressure
      </code>
    </td>
    
    <td>
      <code>
        300
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.pumpControl.idlePressure
      </code>
    </td>
    
    <td>
      <code>
        100
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.pumpControl.idleRpm
      </code>
    </td>
    
    <td>
      <code>
        700
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.pumpControl.maxRpm
      </code>
    </td>
    
    <td>
      <code>
        3150
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.pumpControl.tankFillLitersPerSecond
      </code>
    </td>
    
    <td>
      <code>
        40.0
      </code>
    </td>
  </tr>
</tbody>
</table>

`/jobconfig` manages these values under **Pump Panel**.

</accordion-item>

<accordion-item label="3 · Vehicle pump behavior and stress">

Keep the existing `enabled`, `immobilizeTransferVehicles`, `keepEngineOnDuringTransfer`, `keepEngineOnDuringPump`, `rpmEnabled`, and `activeRpm` values, then add or update:

<table>
<thead>
  <tr>
    <th>
      Config path
    </th>
    
    <th>
      <code>
        1.3.1
      </code>
      
       shipped value
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      <code>
        Config.Hose.vehiclePumpBehavior.immobilizePumpVehicles
      </code>
    </td>
    
    <td>
      <code>
        true
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.vehiclePumpBehavior.keepEngineOnWhenAbandoned
      </code>
    </td>
    
    <td>
      <code>
        true
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.vehiclePumpBehavior.engagementMaxSpeed
      </code>
    </td>
    
    <td>
      <code>
        0.5
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.vehiclePumpBehavior.fuelPercentPerMinute
      </code>
    </td>
    
    <td>
      <code>
        2.5
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.vehiclePumpBehavior.ambientTemperature
      </code>
    </td>
    
    <td>
      <code>
        25.0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.vehiclePumpBehavior.overloadWarningLoad
      </code>
    </td>
    
    <td>
      <code>
        1.0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.vehiclePumpBehavior.warningTemperature
      </code>
    </td>
    
    <td>
      <code>
        100.0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.vehiclePumpBehavior.criticalTemperature
      </code>
    </td>
    
    <td>
      <code>
        115.0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.vehiclePumpBehavior.damageTemperature
      </code>
    </td>
    
    <td>
      <code>
        110.0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.vehiclePumpBehavior.maxEngineDamagePerSecond
      </code>
    </td>
    
    <td>
      <code>
        12.0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.vehiclePumpBehavior.thermalResponse
      </code>
    </td>
    
    <td>
      <code>
        0.04
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.vehiclePumpBehavior.dryRunTemperature
      </code>
    </td>
    
    <td>
      <code>
        145.0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.vehiclePumpBehavior.dryRunDamagePerSecond
      </code>
    </td>
    
    <td>
      <code>
        8.0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.vehiclePumpBehavior.cavitationTemperatureGain
      </code>
    </td>
    
    <td>
      <code>
        45.0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.Hose.vehiclePumpBehavior.updateMs
      </code>
    </td>
    
    <td>
      <code>
        1000
      </code>
      
       instead of <code>
        150
      </code>
    </td>
  </tr>
</tbody>
</table>

`/jobconfig` manages every value in this table.

</accordion-item>

<accordion-item label="4 · Pump hydraulics">

Add the complete `Config.Hose.vehiclePumpBehavior.hydraulics` block:

<table>
<thead>
  <tr>
    <th>
      Field
    </th>
    
    <th>
      Shipped value
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      <code>
        tankIntakePressure
      </code>
      
       / <code>
        tankSupplyGpm
      </code>
    </td>
    
    <td>
      <code>
        35.0
      </code>
      
       / <code>
        1200.0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        hydrantIntakePressure
      </code>
      
       / <code>
        hydrantSupplyGpm
      </code>
    </td>
    
    <td>
      <code>
        150.0
      </code>
      
       / <code>
        1600.0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        pumpIntakePressure
      </code>
      
       / <code>
        pumpSupplyGpm
      </code>
    </td>
    
    <td>
      <code>
        100.0
      </code>
      
       / <code>
        900.0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        cavitationStartRatio
      </code>
    </td>
    
    <td>
      <code>
        0.85
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        frictionLossPsiPerTenMeters
      </code>
    </td>
    
    <td>
      <code>
        10.0
      </code>
    </td>
  </tr>
</tbody>
</table>

`/jobconfig` manages these values under **Pump Panel → Hydraulics**.

</accordion-item>

<accordion-item label="5 · Per-vehicle pump ports">

Add these fields to every entry in `Config.Hose.vehicles`:

<table>
<thead>
  <tr>
    <th>
      Vehicle field
    </th>
    
    <th>
      Shipped value
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      <code>
        pumpIntakeCount
      </code>
    </td>
    
    <td>
      <code>
        2
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        pumpDischargeCount
      </code>
    </td>
    
    <td>
      <code>
        4
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        pumpOutlet1Label
      </code>
    </td>
    
    <td>
      <code>
        "Discharge Rear"
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        pumpOutlet2Label
      </code>
    </td>
    
    <td>
      <code>
        "#1 Discharge"
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        pumpOutlet3Label
      </code>
    </td>
    
    <td>
      <code>
        "#2 Discharge"
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        pumpOutlet4Label
      </code>
    </td>
    
    <td>
      <code>
        "#3 Discharge"
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        pumpIntake1Label
      </code>
    </td>
    
    <td>
      <code>
        "#1 Intake"
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        pumpIntake2Label
      </code>
    </td>
    
    <td>
      <code>
        "#2 Intake"
      </code>
    </td>
  </tr>
</tbody>
</table>

The new `/jobconfig` vehicle cards manage counts, labels, and individual intake/outlet attachment positions. Existing hose and hydrant offsets remain valid fallbacks until you save dedicated port positions.

</accordion-item>
</accordion>

If you use `/jobconfig`, open the Fire job and review **Pump Panel**:

- panel mode and pressure/RPM limits
- engine retention, fuel, heat, damage, and hydraulics
- every pump vehicle's intake/outlet counts, labels, and attachment positions

Save the job after reviewing it. Still edit the three portable-drafting values from section 1 manually.

No old public block was removed. `Config.Hose.vehiclePumpBehavior.updateMs` is the only existing shipped value changed by this patch.

</template>

<template v-slot:data="">

No SQL migration and no new inventory item or inventory image are required for `1.3.1`.

</template>

<template v-slot:verify="">

Keep the dependency order:

```cfg [server.cfg]
ensure sky_base
ensure sky_jobs_base
ensure sky_firejob
```

Test on a staging server:

- [ ] The console reports Base `1.32.1`, Jobs Base `1.35.1`, and Fire `1.3.1`.
- [ ] Simple mode exposes one intake and one discharge; enhanced mode exposes the configured ports.
- [ ] Tank feed/fill, hydrant intake, portable pump intake, hose outlets, water monitor, and deck gun respect live valve and pressure state.
- [ ] Fuel use, temperature, cavitation, overload warnings, and damage respond to pump load.
- [ ] Natural drafting works inside every configured `waterSourceAreas` entry and is rejected outside them.
- [ ] A firefighter can lay down and retrieve an attack hose, including inside an MLO.
- [ ] Missing vehicle doors allow the intended rescue flow.
- [ ] Incident Reports fill the shared tablet and air-bottle storage closes with Escape.
- [ ] The protective-gear HUD shows helmet, mask, jacket, trousers, and boots correctly.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-07-27" title="Version 1.3.0">
<template v-slot:body="">
<callout color="warning" icon="i-lucide-triangle-alert">

Update **sky_base** to `1.32.0` and **sky_jobs_base** to `1.35.0` before updating **sky_firejob**.

</callout>

**Highlights**

- **Placeable persistent extinguisher mounts** - authorized firefighters can use a mounting kit to place complete extinguishers on walls or the ground, remove them through controlled interactions, and preserve their position, rotation, fill, condition, and inventory metadata across restarts.
- **Player carry for Fire crews** - on-duty firefighters can carry and release nearby players through synchronized animations, with configurable distance and movement rules.
- **More reliable multi-patient rescue** - any accessible trapped patient can be treated, extracted, and handed to a moving ambulance independently of the order used for other occupants.
- **Accurate incident completion** - resolved fires, oil spills, tree incidents, and rescue objectives now complete their owning Mission Creator scenario consistently.

**Notable Changes**

- Hose and nozzle props use authoritative shared state so other players and cinematic recordings see the same equipment.
- Hard braking alone no longer traps occupants; crash reports require relevant collision evidence.
- Trapped-player UI can show a localized top-down door overview with closed, open, damaged, and usable-exit states.
- Protective gear can define separate male and female breathing and heat-protection clothing.
- Mission Creator vehicle selection includes localized GTA vehicle categories, and placement gizmos remain interactive without position drift.
- Fire Reports open inside the shared tablet, and firefighters can use shared bodycam/dashcam access supplied by Jobs Base.
- Oil-spill editor size and cleanup state persist correctly through save and autosave.
- Water Monitor radial actions appear reliably, and locally supplied fire vehicles synchronize correctly for other players.
- Patient and caller dialogue renders reliably in a compact in-world rescue speech display.

**Other Changes**

- Added the extinguisher mount model, texture, collision, archetype, inventory image, and localized setup text.
- Reduced idle work for fire, hose, water-transfer, pump, and extinguisher systems.
- Updated the resource version to `1.3.0`.

<update-guide from="1.2.0" resource="sky_firejob" to="1.3.0">
<template v-slot:simplified="">

1. Update **sky_base** to `1.32.0` and **sky_jobs_base** to `1.35.0`.
2. Download **sky_firejob** `1.3.0`, then back up the resource and database.
3. Delete the old resource folder and install the complete new folder, including `source/html`, `stream`, locales, and the extinguisher mount assets.
4. Transfer your server-specific values into the new config files. Keep the new Player Carry, extinguisher placement/maintenance/stock, rescue door overview, and female protective-gear settings.
5. Add `fire_extinguisher_mount_kit` to the intended Fire shops and register the item and image in your inventory.
6. If `Config.AutoExecuteQuery = false`, run the new `/import.sql`. Otherwise the extinguisher table is upgraded automatically.
7. Restart **sky_base**, **sky_jobs_base**, and **sky_firejob** in that order.

</template>

<template v-slot:prepare="">

Update `sky_base` to `1.32.0` and `sky_jobs_base` to `1.35.0`, then stop the server.

<table>
<thead>
  <tr>
    <th>
      Back up
    </th>
    
    <th>
      Safe location
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      Complete <code>
        sky_firejob
      </code>
      
       folder
    </td>
    
    <td>
      Outside the live <code>
        resources
      </code>
      
       folder
    </td>
  </tr>
  
  <tr>
    <td>
      Database
    </td>
    
    <td>
      A restorable SQL dump
    </td>
  </tr>
  
  <tr>
    <td>
      Customized config/editor/function files
    </td>
    
    <td>
      Separate <code>
        custom-config
      </code>
      
       folder
    </td>
  </tr>
</tbody>
</table>

> Do not overlay this release. The resource now includes a rebuilt interface and new streamed extinguisher-mount assets.

</template>

<template v-slot:files="">

Install the complete package:

<table>
<thead>
  <tr>
    <th>
      Action
    </th>
    
    <th>
      Current server path
    </th>
    
    <th>
      New package / destination
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      <strong>
        Delete
      </strong>
    </td>
    
    <td>
      <code>
        resources/[sky]/sky_firejob
      </code>
    </td>
    
    <td>
      Remove only after both backups exist
    </td>
  </tr>
  
  <tr>
    <td>
      <strong>
        Copy
      </strong>
    </td>
    
    <td>
      —
    </td>
    
    <td>
      Copy the new <code>
        sky_firejob
      </code>
      
       folder to <code>
        resources/[sky]/sky_firejob
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <strong>
        Keep from new release
      </strong>
    </td>
    
    <td>
      <code>
        fxmanifest.lua
      </code>
      
      , <code>
        source
      </code>
      
      , and <code>
        source/html
      </code>
    </td>
    
    <td>
      Loads version <code>
        1.3.0
      </code>
      
      , player carry, and the current interface
    </td>
  </tr>
  
  <tr>
    <td>
      <strong>
        Keep from new release
      </strong>
    </td>
    
    <td>
      Complete <code>
        stream
      </code>
      
       folder
    </td>
    
    <td>
      Installs the mount model, texture, archetype, and collision
    </td>
  </tr>
  
  <tr>
    <td>
      <strong>
        Keep from new release
      </strong>
    </td>
    
    <td>
      <code>
        config/locales
      </code>
    </td>
    
    <td>
      Contains the current Fire and setup text
    </td>
  </tr>
  
  <tr>
    <td>
      <strong>
        Keep from new release
      </strong>
    </td>
    
    <td>
      <code>
        config/inventory/fire_extinguisher_mount_kit.png
      </code>
    </td>
    
    <td>
      Copy to your inventory later if required
    </td>
  </tr>
  
  <tr>
    <td>
      <strong>
        Merge only if customized
      </strong>
    </td>
    
    <td>
      Old config/editor/function edits
    </td>
    
    <td>
      Reapply intentional changes inside the matching new files
    </td>
  </tr>
</tbody>
</table>

Confirm that `stream` contains `sky_fire_exting_mount.ydr`, `.ytd`, `.ytyp`, and `_col.ybn`.

</template>

<template v-slot:config="">

Start with the **new** `config/config.lua`; it already contains every required block. Transfer your old server values into it instead of replacing the file. The complete `1.2.0 → 1.3.0` public config migration is grouped below.

<lua-diff-reference>

Compare `config/config.lua`. For customized files under `config/editor`, repeat the comparison one matching file path at a time.

</lua-diff-reference>

<accordion>
<accordion-item label="1 · Player carry defaults">

Keep the complete new `Config.PlayerCarry` block. `/jobconfig` does not manage it.

<table>
<thead>
  <tr>
    <th>
      Field
    </th>
    
    <th>
      Shipped default
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      <code>
        enabled
      </code>
      
       / <code>
        maxDistance
      </code>
      
       / <code>
        requireOnDuty
      </code>
      
       / <code>
        allowSprint
      </code>
    </td>
    
    <td>
      <code>
        true
      </code>
      
       / <code>
        2.5
      </code>
      
       / <code>
        true
      </code>
      
       / <code>
        false
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        carrierAnimation.dict
      </code>
      
       / <code>
        .name
      </code>
      
       / <code>
        .flag
      </code>
    </td>
    
    <td>
      <code>
        "missfinale_c2mcs_1"
      </code>
      
       / <code>
        "fin_c2_mcs_1_camman"
      </code>
      
       / <code>
        49
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        passengerAnimation.dict
      </code>
      
       / <code>
        .name
      </code>
      
       / <code>
        .flag
      </code>
    </td>
    
    <td>
      <code>
        "nm"
      </code>
      
       / <code>
        "firemans_carry"
      </code>
      
       / <code>
        33
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        attachBone
      </code>
    </td>
    
    <td>
      <code>
        0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        attachOffsets.x
      </code>
      
       / <code>
        .y
      </code>
      
       / <code>
        .z
      </code>
    </td>
    
    <td>
      <code>
        0.27
      </code>
      
       / <code>
        0.0
      </code>
      
       / <code>
        0.63
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        attachOffsets.pitch
      </code>
      
       / <code>
        .roll
      </code>
      
       / <code>
        .yaw
      </code>
    </td>
    
    <td>
      <code>
        0.5
      </code>
      
       / <code>
        0.5
      </code>
      
       / <code>
        180.0
      </code>
    </td>
  </tr>
</tbody>
</table>

Change these values only when you deliberately want different carry access, animations, or player alignment.

</accordion-item>

<accordion-item label="2 · Extinguisher mount and placement defaults">

Keep these new values directly under `Config.InteriorExtinguishers`:

<table>
<thead>
  <tr>
    <th>
      Field
    </th>
    
    <th>
      Shipped default
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      <code>
        fullAmmo
      </code>
    </td>
    
    <td>
      <code>
        2000
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        emptyMountModel
      </code>
    </td>
    
    <td>
      <code>
        "sky_fire_exting_mount"
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        emptyMountStreamDistance
      </code>
    </td>
    
    <td>
      <code>
        100.0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        emptyMountOffset
      </code>
    </td>
    
    <td>
      <code>
        { x = 0.0, y = -0.03, z = 0.0 }
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        emptyMountHeadingOffset
      </code>
    </td>
    
    <td>
      <code>
        0.0
      </code>
    </td>
  </tr>
</tbody>
</table>

Keep the complete new `Config.InteriorExtinguishers.placement` block:

<table>
<thead>
  <tr>
    <th>
      Field
    </th>
    
    <th>
      Shipped default
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      <code>
        enabled
      </code>
      
       / <code>
        requireOnDuty
      </code>
    </td>
    
    <td>
      <code>
        true
      </code>
      
       / <code>
        true
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        item
      </code>
    </td>
    
    <td>
      <code>
        "fire_extinguisher_mount_kit"
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        model
      </code>
    </td>
    
    <td>
      <code>
        "prop_fire_exting_3a"
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        consumeItem
      </code>
      
       / <code>
        returnItemOnRemove
      </code>
    </td>
    
    <td>
      <code>
        true
      </code>
      
       / <code>
        true
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        zOffset
      </code>
    </td>
    
    <td>
      <code>
        0.0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        streamDistance
      </code>
      
       / <code>
        pickupDistance
      </code>
    </td>
    
    <td>
      <code>
        150.0
      </code>
      
       / <code>
        2.5
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        dynamic
      </code>
      
       / <code>
        wallPlacement
      </code>
    </td>
    
    <td>
      <code>
        false
      </code>
      
       / <code>
        true
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        wallOffset
      </code>
      
       / <code>
        wallHeadingOffset
      </code>
    </td>
    
    <td>
      <code>
        0.01
      </code>
      
       / <code>
        0.0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        allowedJobs
      </code>
    </td>
    
    <td>
      <code>
        {}
      </code>
    </td>
  </tr>
</tbody>
</table>

An empty `allowedJobs` list uses the normal Fire access rules; populate it only when placement should be restricted further.

</accordion-item>

<accordion-item label="3 · Maintenance, stock, and shop item">

Keep both complete blocks:

<table>
<thead>
  <tr>
    <th>
      Config path
    </th>
    
    <th>
      Shipped default
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      <code>
        maintenance.enabled
      </code>
    </td>
    
    <td>
      <code>
        true
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        maintenance.requireOnDuty
      </code>
    </td>
    
    <td>
      <code>
        true
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        maintenance.allowedJobs
      </code>
    </td>
    
    <td>
      <code>
        { "firefighter" }
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        maintenance.emptyThresholdPercent
      </code>
    </td>
    
    <td>
      <code>
        1.0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        stock.enabled
      </code>
    </td>
    
    <td>
      <code>
        true
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        stock.allowMountRestock
      </code>
    </td>
    
    <td>
      <code>
        true
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        stock.storageStationId
      </code>
    </td>
    
    <td>
      <code>
        ""
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        stock.storageJob
      </code>
      
       / <code>
        stock.storageGrade
      </code>
    </td>
    
    <td>
      <code>
        "firefighter"
      </code>
      
       / <code>
        0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        stock.extinguisherItem
      </code>
      
       / <code>
        stock.extinguisherAmount
      </code>
    </td>
    
    <td>
      <code>
        "WEAPON_FIREEXTINGUISHER"
      </code>
      
       / <code>
        1
      </code>
    </td>
  </tr>
</tbody>
</table>

`stock.storageStationId = ""` leaves station storage unassigned. Set a real station ID before expecting stock-based restocking.

Add the mount kit only to Fire shops that should sell it:

```lua [config/config.lua]
{ name = "fire_extinguisher_mount_kit", label = "Fire Extinguisher Mount Kit", price = 250 }
```

`/jobconfig` manages placement, maintenance, and Fire shop rows. The `stock` block remains a manual config.

</accordion-item>

<accordion-item label="4 · Door overview and female protective gear">

Add `doorOverviewEnabled = true` under `Config.VehicleRescue.playerEntrapment`.

Keep these three new entries under `Config.FireSystem.protectiveGear.breathing.femaleRequiredComponents`:

<table>
<thead>
  <tr>
    <th>
      Component
    </th>
    
    <th>
      <code>
        gearKey
      </code>
    </th>
    
    <th>
      Label
    </th>
    
    <th>
      Drawable / texture
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      <code>
        1
      </code>
    </td>
    
    <td>
      <code>
        "mask"
      </code>
    </td>
    
    <td>
      <code>
        "breathing mask"
      </code>
    </td>
    
    <td>
      <code>
        0
      </code>
      
       / <code>
        0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        5
      </code>
    </td>
    
    <td>
      <code>
        "other"
      </code>
    </td>
    
    <td>
      <code>
        "air tank"
      </code>
    </td>
    
    <td>
      <code>
        48
      </code>
      
       / <code>
        0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        7
      </code>
    </td>
    
    <td>
      <code>
        "other"
      </code>
    </td>
    
    <td>
      <code>
        "breathing harness"
      </code>
    </td>
    
    <td>
      <code>
        32
      </code>
      
       / <code>
        0
      </code>
    </td>
  </tr>
</tbody>
</table>

There is no new breathing `femaleRequiredProps` list. Keep these entries under `heat.femaleRequiredComponents`:

<table>
<thead>
  <tr>
    <th>
      Component
    </th>
    
    <th>
      <code>
        gearKey
      </code>
    </th>
    
    <th>
      Label
    </th>
    
    <th>
      Drawable / texture
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      <code>
        3
      </code>
    </td>
    
    <td>
      <code>
        "top"
      </code>
    </td>
    
    <td>
      <code>
        "firefighter arms"
      </code>
    </td>
    
    <td>
      <code>
        111
      </code>
      
       / <code>
        0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        4
      </code>
    </td>
    
    <td>
      <code>
        "pants"
      </code>
    </td>
    
    <td>
      <code>
        "firefighter pants"
      </code>
    </td>
    
    <td>
      <code>
        42
      </code>
      
       / <code>
        0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        6
      </code>
    </td>
    
    <td>
      <code>
        "shoes"
      </code>
    </td>
    
    <td>
      <code>
        "firefighter boots"
      </code>
    </td>
    
    <td>
      <code>
        13
      </code>
      
       / <code>
        0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        8
      </code>
    </td>
    
    <td>
      <code>
        "top"
      </code>
    </td>
    
    <td>
      <code>
        "firefighter undershirt"
      </code>
    </td>
    
    <td>
      <code>
        44
      </code>
      
       / <code>
        0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        9
      </code>
    </td>
    
    <td>
      <code>
        "top"
      </code>
    </td>
    
    <td>
      <code>
        "firefighter vest"
      </code>
    </td>
    
    <td>
      <code>
        0
      </code>
      
       / <code>
        0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        10
      </code>
    </td>
    
    <td>
      <code>
        "other"
      </code>
    </td>
    
    <td>
      <code>
        "firefighter decals"
      </code>
    </td>
    
    <td>
      <code>
        15
      </code>
      
       / <code>
        0
      </code>
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        11
      </code>
    </td>
    
    <td>
      <code>
        "top"
      </code>
    </td>
    
    <td>
      <code>
        "firefighter jacket"
      </code>
    </td>
    
    <td>
      <code>
        70
      </code>
      
       / <code>
        0
      </code>
    </td>
  </tr>
</tbody>
</table>

Keep one `heat.femaleRequiredProps` entry: `prop = 0`, `gearKey = "helmet"`, label `"firefighter helmet"`, `drawable = 44`, and `texture = 0`.

</accordion-item>

<accordion-item label="5 · What to review in /jobconfig">

If you use `/jobconfig`, open the Fire job and review:

- **Extinguisher Placement** and **Maintenance**
- allowed jobs, empty-mount model/render distance/offset/heading, wall alignment, and custom mounts
- **Door Overview**
- the mount kit in every intended Fire shop
- male and female **Protective Gear**

Then save. These parts still remain manual: `Config.PlayerCarry`, `Config.InteriorExtinguishers.stock`, streamed assets, SQL, and the inventory item/image.

</accordion-item>
</accordion>
</template>

<template v-slot:data="">

Choose exactly one database path:

<table>
<thead>
  <tr>
    <th>
      Your setting
    </th>
    
    <th>
      Required action
    </th>
  </tr>
</thead>

<tbody>
  <tr>
    <td>
      <code>
        Config.AutoExecuteQuery = true
      </code>
    </td>
    
    <td>
      Do not import SQL manually. The first start upgrades the extinguisher table.
    </td>
  </tr>
  
  <tr>
    <td>
      <code>
        Config.AutoExecuteQuery = false
      </code>
    </td>
    
    <td>
      Run the new <code>
        sky_firejob/import.sql
      </code>
      
       once while the server is stopped.
    </td>
  </tr>
</tbody>
</table>

The migration keeps existing `sky_fire_extinguishers` rows and adds `rx`, `ry`, `rz`, `fill_level`, `item_metadata`, `condition_status`, `is_taken`, `is_custom`, `last_inspected_by`, `last_inspected_at`, and `idx_inspection_due (is_taken, last_inspected_at)`. Do not drop the table.

Register `fire_extinguisher_mount_kit` in your active inventory unless the item already exists. The resource does not create the inventory item definition automatically. Copy `config/inventory/fire_extinguisher_mount_kit.png` into the inventory image folder.

</template>

<template v-slot:verify="">

Keep the dependency order:

```cfg [server.cfg]
ensure sky_base
ensure sky_jobs_base
ensure sky_firejob
```

Test on a staging server:

- [ ] The console reports Fire `1.3.0` without SQL, dependency, or missing-stream errors.
- [ ] A mount can be placed on a wall and ground, removed, and returned as an item.
- [ ] Extinguisher take/restock, fill, condition, and restart persistence work.
- [ ] Stock-based restocking uses the configured station, job, grade, item, and amount.
- [ ] Player carry synchronizes and releases correctly.
- [ ] Hose/nozzle props are visible to a second client.
- [ ] Hard braking alone does not trap players; real collisions and unordered multi-patient rescue work.
- [ ] Fire, oil, tree, and rescue objectives complete; oil-spill edits persist.
- [ ] Male and female protective gear rules and the trapped-player door overview display correctly.

</template>
</update-guide>
</template>
</u-changelog-version>

<u-changelog-version date="2026-07-23" title="Version 1.2.0">
<template v-slot:body="">
<callout color="warning" icon="i-lucide-triangle-alert">

Update **sky_base** to `1.31.0` and **sky_jobs_base** to `1.34.0` before updating **sky_firejob**.

</callout>

**Highlights**

- **Vehicle-to-vehicle water transfer** - firefighters can connect compatible vehicles with a hose and transfer tank water through a synchronized, server-controlled workflow that pauses safely when the target tank is full.
- **Operational pump behavior** - connected vehicles can be immobilized, engines can remain running, and configurable pump RPM behavior applies while hoses, cannons, or water monitors are actively spraying.
- **Interior extinguisher pickup system** - configured world extinguishers can be collected, persisted, restored, and restricted by duty or job access.
- **Configurable society rewards** - completed fire, oil-spill, tree, and rescue work can reward the society account of the completing player's configured Fire job.
- **Automatic Missions configuration** - every creator mission can define whether it starts automatically, which jobs qualify, and whether duty is required, while new missions remain manual by default.

**Notable Changes**

- Protective clothing requirements can now identify gear as helmet, mask, top, pants, shoes, or other equipment and display clearer missing-gear feedback.
- Fire Stations and custom clothing labels can be managed more clearly in Job Configurator.
- Tree incidents synchronize chainsaw props, avoid duplicate log pieces, and clean up logs and incident blips more reliably.
- Rescue missions validate entities more carefully and limit completion notifications to the relevant participants.
- Rear-door vehicle-rescue minigames use the correct visual scale.
- Added the Full Dark tablet theme and PNG/WebP item-image support.

**Other Changes**

- Improved configurator reliability during persisted oil-spill updates.
- Updated the resource version to `1.2.0`.

<accordion>
<accordion-item label="Update Instructions">

1. Update **sky_base** to `1.31.0` and **sky_jobs_base** to `1.34.0`.
2. Download **sky_firejob** from the CFX Portal and create a database and resource backup.
3. Replace the `/source` folder, including the rebuilt interface under `/source/html`.
4. Replace `/fxmanifest.lua` so the new extinguisher, water-transfer, pump, reward, and version `1.2.0` scripts are loaded.
5. Replace `/config/locales`.
6. If you do **not** use `/jobconfig`, merge every changed `/config/config.lua` block manually:

  - Add the complete `Config.InteriorExtinguishers` block, including `enabled`, item/label, duty and job access, interaction/scan/restore distances, pickup/restore durations, allowed jobs, and the extinguisher model list.
  - Under `Config.Hose`, add the complete `vehicleTransfer` block with its enable/duty rules, transfer rate/tick, connect and hose distances, external-source and disconnect behavior, and source/target offsets.
  - Under `Config.Hose`, add the complete `vehiclePumpBehavior` block with transfer immobilization, engine behavior, RPM controls, and update timing.
  - Add `societyAccount = "society_firefighter"` to the shipped Fire job in `Config.Jobs`, or use the society account that belongs to each custom Fire job.
  - Add the complete `Config.SocietyRewards` block and configure the enabled state, eligible job rows, and reward amount separately for `fire`, `oil`, `tree`, and `rescue` work.
  - Under `Config.FireScenarioCreator.random`, remove `defaultMinOnDuty` and `manualOnlyScenarios`, then add `missions = {}`. Mission rows now carry their own automatic-start, duty, and job rules.
  - Add the appropriate `gearKey` to every entry under `Config.FireSystem.protectiveGear.breathing.requiredComponents`, `heat.requiredComponents`, and `heat.requiredProps`. Supported categories are `helmet`, `mask`, `top`, `pants`, `shoes`, and `other`.
7. If you use `/jobconfig`, verify Interior Extinguishers, Vehicle Water Transfer, Pump Behavior, Society Rewards, Protective Gear, and Automatic Missions before saving. Keep the complete shipped config blocks available as runtime defaults.
8. Run the updated `/import.sql` if automatic query execution is disabled. It creates `sky_fire_extinguishers` for persistent interior extinguisher state.
9. Ensure the configured extinguisher item or weapon is available through your inventory setup.
10. Restart **sky_firejob** after both base resources and test vehicle water transfer, pump behavior, extinguisher pickup/restore, society payouts for every mission type, protective gear checks, automatic mission filters, and tree/rescue cleanup.

</accordion-item>
</accordion>
</template>
</u-changelog-version>

<u-changelog-version date="2026-07-20" title="Version 1.1.0">
<template v-slot:body="">
<callout color="warning" icon="i-lucide-triangle-alert">

Update **sky_base** to `1.30.0` and **sky_jobs_base** to `1.33.0` before updating **sky_firejob**.

</callout>

**Highlights**

- **Portable water monitor** - firefighters can place, aim, supply, operate, and recover a synchronized water monitor that consumes truck-tank or external water and extinguishes fires through server-authoritative hit validation.
- **Operational helicopter bucket** - configurable helicopter buckets can attach on the ground, fill from water, synchronize their movement, and perform validated high-capacity water drops.
- **Expanded fire simulation** - configurable extinguishing agents, vehicle fuel-fire rules, reignition, long-range rendering, consolidated smoke, ambient 3D sounds, and standalone incident dispatches deepen fire behavior.
- **Reliable vehicle rescue flow** - glass and spreader actions use the configured occupant side, tool minigames, and server validation. The obsolete seatbelt minigame step was removed, so an accessible patient proceeds directly to extraction from the vehicle.
- **Improved hose runtime** - the hose uses configurable performance modes, smoother segmented geometry, better synchronization, and more stable nozzle/vehicle attachment behavior.

**Notable Changes**

- Added synchronized firetruck cannon streams and authoritative cleanup for deployed firefighting equipment.
- Added shared 3D sound playback for fires, flares, chainsaws, and configured effects.
- Added item-based glass hammer and spreader actions to mission rescue workflows.
- Added radial action submenus with one dynamic rescue action per vehicle side.
- Added persisted mission-creator edits, improved gizmo controls, and more reliable scenario/entity cleanup.
- Added server-side validation for player entrapment and reliable completion after every trapped patient is delivered.
- Vehicle fires remain exterior incidents, stale entrapment clears when its vehicle disappears, and resource-owned props are removed on stop.
- Completed the English/German Job Configurator coverage and the bundled runtime locale catalogues.

**Other Changes**

- Simplified water equipment configuration and moved stable geometry values into shared runtime definitions.
- Added the water monitor model to creator prop selection with PNG preview support.
- Normalized streamed metadata declarations and removed an invalid duplicate nozzle archetype.
- Updated the resource version to `1.1.0`.

<accordion>
<accordion-item label="Update Instructions">

1. Update **sky_base** to `1.30.0` and **sky_jobs_base** to `1.33.0`.
2. Download **sky_firejob** from the CFX Portal and create a resource backup.
3. Replace the `/source` folder, including the rebuilt interface under `/source/html`.
4. Replace `/fxmanifest.lua` so the new water equipment, sound, cleanup, stream declarations, and version `1.1.0` are loaded.
5. Replace `/stream` and `/meta` to install the current equipment models and metadata.
6. Replace `/config/locales`.
7. If you do **not** use `/jobconfig`, merge these `/config/config.lua` changes manually:

  - Copy the complete new `Config.WaterMonitor` block and add `{ name = "water_monitor", label = "Water Monitor", price = 750 }` to every Fire Job shop that should sell it.
  - Replace the complete `Config.HeliBucket` block so item/command use, ground attachment, model-specific offsets, rope settings, capacity, filling, and validated dump behavior use the current values.
  - Merge the complete new Hose geometry/performance fields, including `performanceMode = "performance"`, segment/nozzle/vehicle offsets, update distances, and timing.
  - Under `Config.OilSpills`, add `bindDurationMs`, `sweepDurationMs`, `absorbentMinigame`, and `sweepMinigame`.
  - Under `Config.VehicleRescue`, add the current `minigames.glass` and `minigames.spreader` blocks. Remove any old seatbelt-minigame configuration because extraction now starts directly after vehicle access is available.
  - Under `Config.TrappedPatientRescue`, add `interactionDistance = 2.2`, `ambulanceDropoffRadius = 3.0`, and the current treatment duration.
  - Under `Config.FireSystem`, add/merge `syncDistance`, `dispatch`, `render`, `effects.sounds`, and `reignition`.
  - Add the `Config.FireSystem.materials.vehicle_fuel` extinguishing-agent rules; the shipped default blocks water and the water monitor while allowing foam and extinguishers.
8. If you use `/jobconfig`, verify the same water equipment, hose, oil-spill, rescue, dispatch, render, sound, reignition, and extinguishing-agent settings before saving. Model geometry and runtime-only config fields must still be merged from the shipped `config.lua`.
9. Replace `/config/editor/props.lua`, then restore any custom creator prop entries.
10. Register the `water_monitor` item manually if your inventory requires explicit item registration; keep it in the configured Fire Job shop if it should be purchasable.
11. Restart **sky_firejob** after both base resources and test hoses, the water monitor, bucket filling/dumping, fire agents/reignition, rescue extraction without the seatbelt step, standalone dispatches, and cleanup after a resource restart.
12. No SQL migration is required.

</accordion-item>
</accordion>
</template>
</u-changelog-version>

::